Hordhac

Dhinaca gudbinta korontada ee danab sare leh, transformers-ka 220kV ayaa door muhiim ah ka ciyaara hubinta qaybinta tamarta ee hufan. farqiga ugu weyn ee dahaarkau dhexeeya wareegyada transformer-ka waxay matalaan mid ka mid ah qaybaha ugu muhiimsan ee naqshadeynta, taasoo si toos ah u saamaysa isku halaynta transformer-ka, cimriga dheer, iyo waxqabadka. Annagoo ah hoggaamiyeyaasha suuqa ee tignoolajiyada transformers-ka, waxaan aqoonsannahay in naqshadeynta dahaarka ugu habboon ay muhiim u tahay u adkeysiga cadaadiska korantada ee daran, oo ay ku jiraan danab hawlgal joogto ah, Dareenada hillaaca, iyo beddelka kororka.

Maqaalkani wuxuu sahaminayaa hababka falanqaynta garoonka korantada ee casriga ah iyo istaraatiijiyadaha horumarinta wax ku oolka ah ee loogu talagalay farqiga dahaarka ugu weyn ee transformer-ka ee 220kV. Annagoo adeegsanayna teknoolojiyada jilitaanka ee horumarsan iyo mabaadi'da naqshadeynta ee cusub, waxaan si weyn u horumarin karnaa waxqabadka dahaarka transformer-ka, annagoo hubinayna heerka sare ee hawlgalka ee deegaannada ugu baahida badan.

Aasaaska Dahaarka ugu Muhiimsan ee Gudbiyeyaasha 220kV

Farqiga ugu weyn ee dahaarka u dhexeeya dahaarka ee transformers-ka 220kV wuxuu u adeegaa sidii caqabadda dielectric-ga ee ugu weyn, taasoo ka hortagaysa burburka korontada ee u dhexeeya dahaarka danab sare iyo danab hooseeya. Nidaamkan dahaarka waa inuu u adkeystaa xaaladaha shaqada ee caadiga ah laakiin sidoo kale xaalado kala duwan. xaaladaha xad-dhaafka ahkuwaas oo dhaca inta lagu jiro khalkhalka shabaqyada.

Codsiyada 220kV, farqiga dahaarka ayaa badanaa loo adeegsadaa nidaamka caqabado badan lehoo ka kooban dhululubo ama duubab loox ah oo u qaybiya farqiga dhowr tuubo oo saliid ah oo yaryar. Habkani si weyn ayuu u xoojiyaa. danab bilow qayb ka mid ah dheecaanka(PDIV) waxayna ka hortagtaa sameynta buundooyinka wasakhda ah ee u dhexeeya wareegyada. Naqshadeynta aasaasiga ah waxay raacdaa mabda'a "tuubada warqadda khafiifka ah, farqiga saliidda yar", halkaas oo looxyada cadaadiska ay caadi ahaan yihiin 2mm dhumucdiis, farqiga saliidda ee u dhexeeya caqabadahana wuxuu u dhexeeyaa 6-10mm.

Qaybinta goobta korantada ee ku jirta meelahan banaan waa wax aan isku mid ahayn, oo leh fiirsashada walbahaarkaka dhaca geesaha rogrogmada, qalooca hagaha, iyo is-dhexgalka dahaarka. Iyadoo aan la helin habayn habboon oo naqshadaysan, meelahan cidhiidhiga badan leh ee ku yaal deegaanku waxay bilaabi karaan hawlo qayb ka mid ah dahaarka, taasoo horseedaysa burburka dahaarka oo sii socda iyo guuldarro suurtagal ah.

Farsamooyinka Falanqaynta Goobta Korontada

Jilidda Habka Curiyaha Dhammaystiran (FEM)

Naqshadaynta dahaarka casriga ah waxay si weyn ugu tiirsan tahay falanqaynta walxaha kama dambaysta ah(FEA) si loo sameeyo khariidaynta saxda ah ee goobta korantada. Iyadoo loo qaybinayo joomatari dahaarka kumanaan walxood oo kala go'an, FEM waxay xisaabin kartaa qaybinta suurtagalka ahiyo xoogga garoonkaiyadoo si sax ah loo eegayo. Transformers-ka 220kV, falanqayntani waxay inta badan diiradda saartaa saddex gobol oo muhiim ah: dahaarka dhamaadka sare, qaybta dhexe ee u dhaxaysa wareegyada, iyo dahaarka dhammaadka hoose.

Jilitaannadeennu waxay muujinayaan in xoogga ugu sarreeya ee goobta korantada ee transformers-ka 220kV ay badanaa ka dhacaan goobta. geesaha dusha sare ee gudahaee dabaylaha danab-sare leh, gaar ahaan meelaha u dhow qaybaha dhammaadka xariiqda. Inta lagu jiro tijaabooyinka kicinta hillaaca (1050kV ee nidaamyada 220kV), meelahani waxay la kulmi karaan xoogagga goobta oo ka badan 8-9kV/mm, iyagoo u dhawaanaya xadka burburka ee agabka dahaarka.

Aqoonsiga Aagagga Walbahaarka ee Khatarta ah

Iyada oo loo marayo falanqayn dhammaystiran oo ku saabsan goobta korantada, waxaan aqoonsannay dhowr aag oo walaac muhiim ah oo u baahan fiiro gaar ah oo ku saabsan transformers-yada 220kV:

  • Gobollada cidhifyada ah: Geesaha fiiqan ee darafyada wareegsan waxay abuuraan diirad muhiim ah oo goobta ah, taasoo u baahan farsamooyin qiimeyn oo gaar ah.
  • Is-dhexgalka u dhexeeya dahaarka adag iyo dareerahaSifooyinka kala duwan ee dielectric ee looxa pressboard-ka iyo saliiddu waxay abuuraan xoojinta goobta ee is-dhexgalkooda.
  • Meelaha laga baxo ee hogaaminta: Meelaha kala-guurka ah ee ay ka baxaan fiilooyinka danab sare waxay soo bandhigaan qaybinta goobta oo si gaar ah u adag oo u baahan falanqayn saddex-geesood ah.

Beddelayaasha 220kV, xoogga ugu badan ee goobta korantada ayaa badanaa ka dhaca saxannada ugu horreeya ee u dhow dhammaadka xariiqda iyo meelaha isgoysyada u dhexeeya saxannada isku xiran iyo kuwa caadiga ah inta lagu jiro xaaladaha degdegga ah. Meelahani waxay u baahan yihiin tallaabooyin dahaadh oo la xoojiyay si looga hortago cillad degdeg ah.

Istaraatiijiyadaha Horumarinta ee Farqiga Dahaarka ee ugu Muhiimsan

Hagaajinta Joomatari

Qaabaynta elektrodewaxay ka dhigan tahay mid ka mid ah xeeladaha ugu waxtarka badan ee lagu hagaajinayo qaybinta goobta. Iyadoo lagu beddelayo geesaha fiiqan oo leh profiles qaloocaniyo hirgelinta elektroodhada toroidal-ka, waxaan yareyn karnaa xoogga ugu badan ee goobta ilaa 30-40%. Transformers-yada 220kV, tan waxaa ka mid ah:

  • Siddooyin dhammaadka taagan(SER) ee terminaalka wareegaya si loo abuuro jaangooyooyin suurtagal ah oo siman.
  • Faraanti xagaloo leh astaamo qiyaasa khadadka qalabka, taasoo si weyn u yareynaysa cadaadiska taabashada ee dusha sare ee looxa cadaadiska.
  • Koonooyinka cadaadiskagoobaha muhiimka ah si loo xakameeyo kala duwanaanshaha goobta loona yareeyo isku-urursiga.

Gacanka hagaajinta qalooca ayaa si gaar ah muhiim u ah - kordhinta gacanka geeska ee qalabka korontada iyo giraangiraha taagan waxay si weyn u yareyn kartaa xoojinta goobta (xoogga goobta ∝ 1/raadiyaha).

Qalabka Dahaarka Sare

Xulashada agabku waxay door muhiim ah ka ciyaartaa kor u qaadista waxqabadka dahaarka. Transformers-yadayada 220kV waxay isticmaalaan:

  • Saxanka cadaadiska cufnaanta sare lehiyadoo la hagaajiyay xasilloonida cabbirka iyo xoogga dielectric-ga oo sarreeya.
  • Waraaqo si heer sare ah loo cusbooneysiiyaykuwaas oo bixiya adkeysi kuleyl oo heer sare ah, iyagoo ilaalinaya sifooyinka dielectric heerkulka sare.
  • Alaabada Nanocomposite-ka lagu xoojiyayhalkaas oo nanoparticles (SiO₂, Al₂O₃) lagu daro epoxy ama saliiddu ay xoojiso xoogga dielectric 20-30% iyadoo kor u qaadaysa gudbinta kulaylka.

Agabkan casriga ah wuxuu u oggolaanayaa naqshado dahaadh oo isku dhafan iyadoo la ilaalinayo ama xitaa la hagaajinayo faa'iidooyinka isku halaynta. Tusaale ahaan, hirgelinta nidaamyada dahaarka nanocomposite waxay kordhin kartaa cimriga dahaarka 20-30% marka loo eego agabka caadiga ah.

Qaabeynta Nidaamka Dahaarka

Hagaajinta qaab-dhismeedka jireed ee qaybaha dahaarka waxay keenaysaa horumar muhiim ah:

  • Nidaamyada dahaarka ee la qiimeeyayhalkaas oo dhumucda dahaarka ay ku kala duwan tahay iyadoo loo eegayo qaybinta danabka ee ku teedsan wareegga.
  • Hagaajinta meelaynta caqabadahaiyadoo la adeegsanayo falanqaynta FEM si loo go'aamiyo booska ugu habboon ee looxa riixa ee yareeya cadaadiska ugu badan ee farqiga saliidda.
  • Cabbirka tuubada saliiddakaas oo dheellitira baahiyaha korontada (farqiga yar ee PDIV sare) iyo baahiyaha qaboojinta (socodka saliidda ku filan).

Transformers-yada 220kV, waxaan helnay taas farsamooyinka isku dhafan ee wareeggaiyadoo boqolleyda isku-dhafka ah ee ka sarreeya 65-70% ay si weyn u hagaajiyaan qaybinta danabka kicinta, taasoo yaraynaysa walbahaarka ku yimaada saxannada ugu horreeya ilaa 50% marka la barbar dhigo naqshadaha caadiga ah.

Daraasad Kiis: Hirgelin Guul leh oo ku saabsan Transformer-ka 220kV

Mashruucyadeennii dhawaan ee ku lug lahaa qalab koronto oo 220kV ah oo awood badan leh ayaa muujinaya waxtarka istaraatiijiyadahan horumarinta. Naqshadeynta bilowga ah waxay muujisay fiirsashada goobta korontada oo xad dhaaf ah (ilaa 9.5kV/mm) ee farqiga ugu weyn ee dahaarka u dhexeeya dahaarka danab sare iyo danab hoose, gaar ahaan meel u dhow dhammaadka rogrogmada.

Iyada oo loo marayo falanqaynta FEM ee soo noqnoqda iyadoo la adeegsanayo software gaar ah (HSSSM), waxaan hirgelinay xirmo horumarineed oo dhammaystiran:

  1. Giraangirta elektaroonigga ah ee dib loo habeeyayoo leh qalooc iyo meelayn la hagaajiyay.
  2. Faraantiyo xagal dheeraad ahdhamaadka rogrogmada si loo qaybiyo mugga saliidda loona hagaajiyo xoogga gurguurta.
  3. Qaabaynta xayndaabka wax laga beddelayabuurista meelo yaryar oo saliid ah oo isku mid ah (6-8mm) halkii ay ka ahaan lahaayeen meelo waaweyn oo asal ah (12-15mm).

Natiijooyinku waxay ahaayeen kuwo cajiib ah: xoogga ugu badan ee goobta ayaa hoos loogu dhigay 6.2kV/mm (horumar 35% ah), iyadoo qaybin goobeed oo isku mid ah laga sameeyay qaab-dhismeedka dahaarka. Transformer-ka wax laga beddelay ayaa si guul leh uga gudbay dhammaan tijaabooyinka caadiga ah iyo nooca, oo ay ku jiraan tijaabooyinka danab u adkeysiga soo noqnoqoshada awoodda (460kV muddo 1 daqiiqo ah) iyo hillaaca (1050kV), iyadoo heerarka sii deynta qayb ahaan ay si joogto ah uga hooseeyaan 10pC.

Tixgelinta Wax Soo Saarka iyo Tayada

Xitaa naqshadda ugu casrisan waxay noqotaa mid aan waxtar lahayn iyada oo aan la helin kontaroollo wax soo saar oo sax ah. Barnaamijkayaga hubinta tayada ee dahaarka transformer-ka 220kV waxaa ka mid ah:

  • Xakamaynta habka tirakoobkainta lagu jiro sameynta guddiga saxaafadda iyo isu-imaatinka qaybaha.
  • Qallajinta faakuumka iyo ku dahaadhida saliiddahababka hubinaya in si buuxda looga saaro qoyaanka iyo gaasaska bilaabi kara dheecaan qayb ahaan ah.
  • Khariidadda sii deynta qayb ahaaninta lagu jiro tijaabooyinka degdegga ah si loo aqoonsado loona saxo cilladaha wax soo saarka.

Beddelayaasha 220kV, waxaan hirgelinnaa hab-raacyo nadaafadeed oo adag inta lagu jiro isku-dubaridka iyo hawlgallada haamaha, maadaama xitaa wasakhda yar yar ay si weyn u yareyn karto xoogga dahaarka ee meelaha korontada sare leh.

Isbeddellada Mustaqbalka ee Tiknoolajiyada Dahaarka

Horumarka dahaarka transformer-ka ayaa sii socda iyadoo leh dhowr horumar oo rajo leh:

  • Tiknoolajiyada mataanaha dhijitaalka ahabuurista nuqullo casri ah oo nidaamyada dahaarka ah si loola socdo waxqabadka waqtiga-dhabta ah iyo dayactirka saadaalinta.
  • La socodka xaaladda sareiyadoo la adeegsanayo dareemayaasha fiber optic-ga ee ku dhex jira si loola socdo dhaqdhaqaaqa qayb ahaan ka baxaya iyo meelaha kulaylka ah inta lagu jiro nolosha shaqada ee transformer-ka.
  • Dareeraha dahaarka deegaanka u fiicansida esters-ka dabiiciga ah ee bixiya meelaha dabka lagu shido oo sareeya iyo hagaajinta iswaafajinta deegaanka iyadoo la ilaalinayo waxqabadka dielectric.

Codsiyada 220kV, waxaan si gaar ah ugu faraxsanahay codsiyada barashada mashiinkaHagaajinta naqshadeynta dahaarka, halkaas oo algorithms-ku si dhakhso ah u qiimeyn karaan kumanaan kala duwanaansho naqshadeed si loo aqoonsado qaabaynta ugu habboon ee isku dheelitirta tixgelinta korontada, kulaylka, iyo dhaqaalaha.

Gunaanad

Hagaajinta farqiga dahaarka ugu weyn ee transformer-ka ee 220kV ee isku-xidhka coil waxay ka dhigan tahay caqabad injineernimo oo casri ah oo u baahan aqoon qoto dheer oo ku saabsan aragtida dielectric, awoodaha jilitaanka ee horumarsan, iyo khibrad wax soo saar oo wax ku ool ah. Iyada oo loo marayo falanqaynta garoonka korontada oo dhammaystiran iyo istaraatiijiyadaha horumarinta ee la beegsanayo, waxaan si weyn u horumarin karnaa isku halaynta transformer-ka iyo cimri dhererka.

Habkayagu wuxuu muujinayaa in naqshadaynta dahaarka istaraatiijiyadeed aysan kaliya hagaajinayn waxqabadka dielectric laakiin sidoo kale ay suurtogal ka dhigayso isbeddello isku dhafan oo kharash-ool ah. Annagoo hirgelinayna farsamooyinkan horumarsan, waxaan bixinnaa isbeddello ka sarreeya heerarka warshadaha iyadoo macaamiisheenna siinaysa isku hallayn hawlgal oo heer sare ah iyo faa'iidooyinka guud ee lahaanshaha.

Maadaama tiknoolajiyadu ay sii kordheyso, waxaan weli ka go'annahay inaan isku darno horumarkii ugu dambeeyay ee naqshadeynta dahaarka, annagoo hubinayna in macaamiisheennu ay ka faa'iideystaan ​​​​xaladaha ugu kalsoonida badan uguna hufan ee laga heli karo suuqa.

La xiriir kooxdayada injineerinka maantasi aan uga wada hadalno sida khibraddayada gaarka ah ee naqshadeynta dahaarka ay u xoojin karto waxqabadka iyo isku halaynta mashaariicdaada transformer-ka 220kV.