+86 18068001229 Transformer-ka Amorphous Daawaha iyo Transformer-ka Birta Silicon
Ma taqaanaa farqiga u dhexeeya Transformer-ka Amorphous Daawahas iyo transformers-ka birta silicon ee caadiga ah? Maadaama ay tahay soo-saare transformer ah oo leh khibrad 15+ sano ah, JZP waxay sharraxaysaa farqiga u dhexeeya labada nooc ee transformers-ka. Ma aha oo kaliya farqi ku yimaada agabka; waa dagaal tignoolajiyadeed oo u dhexeeya hufnaanta tamarta, kharashka, iyo isbeddellada mustaqbalka.
Amorphous Alloy VS. Transformer-ka Caadiga ah
Transformer-ka Birta Silicon-ka Caadiga ah
Transformers-yada caadiga ah waxay leeyihiin xudunta laga sameeyay xaashiyo bir ah oo silikoon ah oo qabow lagu duubay, oo atomkoodu ku habboon yahay qaab-dhismeed kristal ah oo caadi ah.
Habayntan nidaamsan waxay keentaa iska caabin birlabeed oo aad u hooseysa marka birlabku ku socdo jihada rogrogmada, taasoo keenta waxqabad aad u wanaagsan. Si kastaba ha ahaatee, wali waa kuwo crystalline ah, birlabkuna wuxuu isticmaalaa tamar, taasoo soo saarta "khasaaro hysteresis ah." Intaa waxaa dheer, xaashida birta ah ee silikoonku waxay leeyihiin dhumuc gaar ah, goobaha birlabkuna waxay keenaan "qulqulo eddy ah" oo gudaha ku jira, taasoo horseedaysa "khasaaro eddy ah," oo si wadajir ah loogu yaqaan "khasaaro bir ah."
Transformer-ka Amorphous Daawaha
Xudunta qalabka isbeddelka ee aan qaab-dhismeedka lahayn waxa laga sameeyay ribboor aan qaab-dhismeed lahayn, oo sidoo kale loo yaqaan "muraayad bir ah." Qaab-dhismeedkeeda atamka waa mid fowdo ah oo aan nidaamsanayn. Qaab-dhismeedkan waxaa lagu sameeyaa iyadoo si degdeg ah loo qaboojiyo dhalaal heerkul aad u sarreeya oo ku socda xawaare malaayiin darajo ilbiriqsi kasta, waana hab gaar ah. Cudurkan atamka ee masaafada dheer wuxuu si weyn u yareeyaa khasaaraha hysteresis; dhumucdiisuna aad u khafiifsan tahay iyo iska caabintiisa sare waxay sii yareeyaan khasaaraha hadda socda ee aan qaab-dhismeedka lahayn.
Isbarbardhigga Waxqabadka
| Cabbirka Isbarbardhigga | Transformer-ka Amorphous Daawaha
| Transformer-ka Birta Silicon-ka Caadiga ah
| Falanqaynta iyo Fasiraadda
|
| Khasaaraha Muhiimka ah
| Aad u Hooseeya
| Sare
| Khasaaraha aan culayska lahayn, celcelis ahaan, 60%-80% way ka hooseeyaan kuwa la midka ah ee beddelaya birta silikoon ee S13/S14.
|
| Hadda oo aan la rarin
| Yar
| Weyn
| Koronto aan culays lahayn waxaa lagu dhimi karaa qiyaastii 40%-80%, taasoo la macno ah saameyn yar oo ku timaadda shabakadda iyo khasaaraha khadadka hoose.
|
| Heerka Waxtarka Tamarta
| Aad u Sare
| Sare
| Transformers-ka aan qaab-dhismeedka lahayn si fudud ayay u buuxin karaan heerka hufnaanta tamarta ee heerka I ee qaranka, taasoo ka dhigan hufnaanta tamarta ugu sarreysa marka la barbar dhigo transformers-ka birta silicon (badanaa heerka II ama fasalka III).
|
| Kharashka Wax Soo Saarka
| Sare
| Hooseeya
| Xarigga dahaarka ee aan qaab-dhismeedka lahayn waa qaali, adag, oo jaban, hababka jarista iyo daadintana waa kuwo adag, taasoo keentay in kharashka wax soo saarku uu ka sarreeyo 20%-35% birta silikoon ee isku awoodda ah. Tani waa khasaaraha ugu weyn.
|
| Xoogga Farsamada
| Hoose
| Sare | Xarigga dahaarka ee aan qaab-dhismeedka lahayn waa mid adag oo jaban, oo leh iska caabin liidata oo shoogga iyo gariirka. Taxaddar gaar ah waa in la sameeyaa inta lagu jiro rarista, rakibidda, iyo shoogga wareegga gaaban. Xaashida birta ah ee silikoonku aad bay u adag tahay waxayna leedahay iska caabin saameyn oo ka wanaagsan.
|
| Cufnaanta qulqulka magnetic shaqaynta
| Hoose (1.3-1.5T)
| Sare (1.6-1.8T)
| Cufnaanta qulqulka magnetic-ga ee walxaha aan qaab-dhismeedka lahayn waa mid hooseeya, taasoo la macno ah in aag weyn oo isgoys ah oo xudunta ah loo baahan yahay isla awooddaas, taasoo horseedi karta koror yar oo ku yimaada mugga iyo miisaanka qalabka wax-soo-saarka.
|
| Buuqa Hawlgalka
| Waxoogaa Sare
| Hoose
| Saamaynta birlabta (isbeddel yar oo ku yimaada cabbirka maaddada marka la birlabeeyo) ee biraha aan qaab-dhismeedka lahayn ayaa ka muuqata kuwa biraha silikoon, taasoo keenta hum xoogaa ka sarreeya (qiyaastii 2-5 dB ka sarreeya) inta lagu jiro hawlgalka. Waxaa laga yaabaa in loo baahdo in si gaar ah loo maareeyo meelaha xasaasiga u ah buuqa.
|
| Waxqabadka Deegaanka
| Aad u fiican
| Wanaagsan | Khasaaraha aan culayska lahayn ee aadka u hooseeya waxay la macno tahay keydin tamar oo muhiim ah wareegga nolosha oo dhan (20-30 sano), taasoo la mid ah yareynta qiiqa kaarboon dhowr tan ama xitaa tobanaan tan. |
Beddelayaasha birta silikoon ee caadiga ah: Maalgashi yar oo bilow ah, laakiin kharash koronto oo sarreeya. Khasaarahooda aan rarka lahayn waxay dhacaan 24 saacadood maalintii, iyagoo isticmaalaya koronto joogto ah ilaa inta gudbiyuhu ku xiran yahay shabakadda.
Isbeddellada isku-dhafka ah ee aan qaab-dhismeedka lahayn: Maalgashi bilow ah oo sarreeya, laakiin kharash koronto oo aad u hooseeya. Kaydintooda tamarta ayaa laga yaabaa inay noqoto mid aan la dafiri karin hal maalin, laakiin inta lagu jiro wareegga noloshooda oo dhan (20-30 sano), keydintu way adkaan kartaa.
Shirkadaha leh tiro badan oo ah Transformer-ka Qaybintaiyo arrimo culeys yar (sida shirkadaha shabakadda korontada, xarumaha xogta, iyo dhismayaasha ganacsiga ee waaweyn), faa'iidooyinka dhaqaale ee transformers-ka aan qaabaysnayn ayaa aad u soo jiidasho leh.