+86 18068001229 Nooca Qallalan ee Nooca ah ee Nooca ah ee Nooca ah ee loogu talagalay Warshadaha Korontada Nukliyeerka
- Waa maxay Transformer Nooca Qallalan ee Fasalka 1E?
Marka hore, waa lagama maarmaan in la fahmo fikradda asaasiga ah ee "Fasalka 1E".
Fasalka 1E: Kani waa kala-soocid badbaado oo laga soo qaatay heerarka naqshadeynta warshadda tamarta nukliyeerka (tusaale ahaan, IEEE Std 323 ee Mareykanka ama GB/T 12727 ee Shiinaha). Waxay tilmaamaysaa qalabka korontada iyo nidaamyada lagama maarmaanka u ah fulinta hawlaha badbaadada muhiimka ah, sida xiritaanka degdegga ah ee fal-galka, go'doominta xakamaynta, qaboojinta xudunta fal-galka, iyo ka hortagga sii deynta walxaha shucaaca.
Transformer Nooca Qalalan: Transformer-kiisa oo aan lagu dhex milmin saliid dahaarka leh laakiin lagu ilaaliyo agab adag oo dahaarka leh (tusaale ahaan, epoxy resin).
Sidaa darteed, Transformer Nooca Qallalan ee Nooca 1E waxaa lagu qeexaa: Transformer nooca qalalan oo si gaar ah loogu talagalay inuu koronto siiyo nidaamyada heerka badbaadada (1E) ee warshadda tamarta nukliyeerka. Waa inay awood u leedahay inay si kalsooni leh oo joogto ah u shaqeyso xaaladaha caadiga ah, xaaladaha shilalka (tusaale ahaan, dhulgariir, LOCA - Khasaaraha Shilka Qaboojiyaha), iyo deegaannada ka dambeeya shilalka muddo cayiman.
Si fudud haddii loo dhigo, waa mid ka mid ah "ilaha korontada ee nolosha" ee nidaamyada badbaadada ee warshadda tamarta nukliyeerka.
- Maxay tahay sababta ay tahay in Warshadaha Korontada Nukliyeerku ay u isticmaalaan Transformers-ka Heerka 1E?
Badbaadada warshadda korontada nukliyeerka ayaa ah mudnaanta ugu sarreysa. Doorka transformers-ka Heerka 1E waa inay bixiyaan tamar xasilloon oo la isku halleyn karo oo loogu talagalay qalabka badbaadada muhiimka ah xaaladaha ugu daran, oo ay ku jiraan:
Nidaamyada qaybinta ee la xiriira badbaadada
Qalabka lagu beddelo matoorada naaftada ee degdegga ah
Nidaamyada xakamaynta iyo ilaalinta fal-galka
Matoorada loogu talagalay bambooyinka Nidaamka Qaboojinta Aasaasiga ah ee Degdegga ah (ECCS)
Nidaamyada la socodka shilalka kadib
Nidaamyada hawo-qaadista iyo go'doominta
Lumitaanka awoodda nidaamyadan waxay keeni kartaa cawaaqib xumo. Sidaa darteed, transformers-ka Heerka 1E waa qayb muhiim ah oo ka mid ah istaraatiijiyadda difaaca qoto dheer ee warshadda tamarta nukliyeerka.
- Shuruudaha Muhiimka ah & Tiknoolajiyada Muhiimka ah ee loogu talagalay Transformers-ka Nooca Qallalan ee Fasalka 1E
Transformers-ka fasalka 1E aad bay uga duwan yihiin transformers-ka warshadaha caadiga ah ama kuwa ganacsiga ee nooca qalalan. Shuruudohooda asaasiga ah waxaa lagu muujiyey meelaha soo socda:
- Kalsoonida Ugu Sareysa iyo Aqoonta Deegaanka (Qalabka K1, K2, K3)
Warshadaha tamarta nukliyeerka waxay u kala saaraan qalabka Heerka 1E iyagoo ku saleynaya darnaanta xaaladaha deegaanka ee ay tahay inay u adkaystaan. Transformers-ku waxay u kala baxaan qaybaha u dhigma:
Qaybta K1: Waxaa lagu rakibay gudaha meesha lagu hayo. Waa inay u adkaystaan xaaladaha caadiga ah, dhulgariirrada (OBE/SSE), iyo heerkulka sare, cadaadiska sare, qoyaanka sare, iyo deegaanka buufinta kiimikada ee ka dhasha Shilka Qaboojiyaha ee Lumay (LOCA), waana inay sii shaqeysaa ka dib shilka. Kani waa qaybta ugu adag.
Qaybta K2: Waxaa lagu rakibay gudaha meesha la dhigay laakiin waxaa loo baahan yahay oo keliya in ay u adkeysato xaaladaha caadiga ah iyo dhulgariirrada, marka laga reebo deegaanka LOCA.
Qaybta K3: Waxaa lagu rakibay meel ka baxsan xakamaynta laakiin qayb ka ah nidaamka la xiriira badbaadada, oo loo baahan yahay si loogu adkeysto xaaladaha caadiga ah iyo dhulgariirka.
Tiknoolajiyada Muhiimka ah ee La Xiriira:
Nidaamka Dahaarka Gaarka ah: Wuxuu adeegsadaa agab dahaareed heer sare ah, dab-celiya, qoyaan-celiya, iyo shucaac-celiya (tusaale ahaan, resin epoxy oo heer sare ah). Habab horumarsan oo lagu shubo/lagu shubo (tusaale ahaan, tignoolajiyada dahaarka khafiifka ah, Dahaarka Cadaadiska Faakuumka) ayaa loo adeegsadaa si loo hubiyo qaab-dhismeed dahaareed cufan oo ka xor ah madhan, oo leh heerar dheecaan qayb ahaan aad u hooseeya.
Iska caabinta Ololka Sare (F1 Class): Agabku waa is-damiye mana sii wadi doonaan gubashada xitaa marka la kulmo olol furan, taasoo ka hortagaysa faafitaanka dabka.
Xoogga Farsamo ee Adag: Qaab-dhismeedka transformer-ka oo dhan (oo ay ku jiraan wareegyada, qaababka, iwm.) waa inuu u adkeystaa Dhulgariirka Amniga ah ee Xiritaanka (SSE) iyada oo aan waxyeello soo gaarin, taasoo hubineysa hufnaanta shaqada. Tan waa in lagu xaqiijiyaa iyada oo loo marayo Falanqaynta Cunsurrada Xaddidan (FEA) ee saxda ah iyo tijaabinta aqoonta dhulgariirka ee adag.
- Hubinta Tayada iyo Shahaadada Adag
Barnaamijka QA-ga Nukliyeerka: Wareegga nolosha oo dhan - laga bilaabo naqshadeynta, soo iibsiga agabka, wax soo saarka, tijaabinta, ilaa gaarsiinta - waa inay u hoggaansamaan barnaamijka hubinta tayada nukliyeerka (badanaa ku salaysan HAF 003 ama 10 CFR 50 Lifaaqa B), hubinta xakamaynta iyo raadraaca oo dhammaystiran.
Shahaadada & Shahaadada: Transformer-ku waa inuu ka gudbaa imtixaanada nooca iyo imtixaanada aqoonsiga dhulgariirka oo ay sameeyaan hay'ad ay aqoonsan tahay hay'adda qaran ee sharciyeynta badbaadada nukliyeerka (tusaale ahaan, NNSA ee Shiinaha) si loo muujiyo u hoggaansanaanta heerarka Heerka 1E. Kani waa "ruqsad" uu ku galo suuqa.
- Naqshadeynta iyo Tijaabinta Waxqabadka Gaarka ah
Iska caabbinta Gabowga Shucaaca: Gaar ahaan kuwa wax ka beddela qaybta K1, agabka dahaarka iyo qaybaha qaab-dhismeedka waa in la qiimeeyaa si loo hubiyo inaysan jirin wax hoos u dhac ah oo ku yimaada waxqabadka marka loo eego qiyaasta shucaaca ee la filayo inta ay nool yihiin.
Tijaabooyinka Caadiga ah & Nooca Adag: Marka laga reebo tijaabooyinka caadiga ah (saamiga, iska caabinta, luminta culayska/raajada aan lahayn, dielectric, heerka dhawaaqa, iwm.), tijaabooyin gaar ah ayaa qasab ah, sida:
Cabbirka Qayb ka mid ah Daadinta: Shuruudaha waa kuwo aad u adag, oo caadi ahaan u baahan heerar ka hooseeya 5-10 pC, si loo hubiyo isku halaynta dahaarka muddada dheer.
Tijaabooyinka Korontada Kacsiga (Hillaaca & Is-beddelka Kacsiga).