+86 18068001229 Go'aaminta Awoodda Rarka ugu Badan ee KW ee Transformer-ka 1000kVA
Sida Loo Xisaabiyo Qiimaynta Culayska KW ee Transformer-ka 1000kVA Iyada oo Ku Salaysan Qodobka Korontada
Iyada oo qalab beddelka 1000kVA ah oo nooc hore ah uu hadda hayo culays dhan qiyaastii 200kW, ma beddeli karaa baahida sii kordheysa haddii aan qorsheyneyno inaan ku darno culays cusub oo qiyaastii 600kW ah? Su'aashani waxay si gaar ah ugu wareegsan tahay fikrad aasaasi ah: xiriirka iyo kala soocida kVA iyo kW.
Xiriirka iyo kala duwanaanshaha kVA iyo kW
kVA (kilovolt-ampere) waa cutubka awoodda muuqata, halka kW (kilowatt) uu matalo cutubka awoodda firfircoon. Marka laga soo tago awoodda muuqata iyo awoodda firfircoon, waxaa sidoo kale jira awood falgal ah, oo lagu cabbiro kvar (kilovar).
Waa maxay faraqa u dhexeeya awoodda firfircoon, awoodda falgalka, iyo awoodda muuqata?
Awood Firfircoon: Marka lagu cabbiro watts (W), waxay matalaysaa tamarta dhabta ah ee la isticmaalay ama shaqada waxtarka leh ee uu sameeyo wareegga (tusaale ahaan, kuleylinta, iftiinka).
Awoodda Falcelinta: Iyadoo lagu cabbiro volt-amperes reactive (VAR), waxay taageertaa goobaha birlabta ee culaysyada soo-jiidashada (tusaale ahaan, matoorada) laakiin ma shaqeeyaan si dhab ah. Tusaale ahaan, haddii qalab koronto uu ka kooban yahay kaabayaal ama gariirado, qaybahani si joogto ah ayay u dallacayaan oo u daadanayaan inta qalabku shaqeynayo. Maadaama kaabayaal/gariiradu aysan dhab ahaantii isticmaalin tamarta korontada inta lagu jiro habkan dallacaadda/daadinta, awoodda la xiriirta waxaa loogu yeeraa awood falcelis.
Awoodda Muuqda: Marka lagu cabbiro volt-amperes (VA), waa isku-darka awoodda firfircoon iyo tan falgalka ah, oo matalaysa awoodda guud ee wareegga. Isha korontada (badanaa transformer ama matoor) waa inay siisaa awood firfircoon oo keliya laakiin sidoo kale awood falgal ah aaladaha korontada. Tani waa sababta oo ah, inkastoo capacitors-ka ku jira qalabku aysan isticmaalin awood firfircoon, dallacaadda joogtada ah iyo sii deynta ayaa weli u baahan isha korontada si ay u qoondayso qayb ka mid ah awooddeeda si ay u taageerto hawshan.
Ka dib markaan caddayno fikradahan, hadda waxaan baari karnaa xiriirkooda, taas oo nagu hoggaaminaysa fikrad kale oo muhiim ah: qodob awood. Qadarka awoodda firfircoon ee isha korontadu keeni karto waxay si toos ah ugu xiran tahay qodobka awoodda.
Haddii korontada lagu qiimeeyo $1 kiilowatt-saacaddiiba (kWh), transformer-ka ku shaqeeya factor awoodeedu tahay 0.6 wuxuu soo saari karaa $600/saacaddii dakhli dhaqaale. Marka factor awoodeedu ay ka soo kabato 0.9, transformer-ka isku midka ah wuxuu soo saari karaa 900/saacaddii45 dakhli. Iyadoo faa'iidooyinka dhaqaale ee hagaajinta factor awoodeed ay muuqdaan, saameynteeda farsamo ee ballaaran (tusaale ahaan, hagaajinta xasilloonida shabakadda iyo yaraynta khasaaraha tamarta) waxay ka baxsan tahay faa'iidooyinkan degdegga ah.
Immisa kiilowatts (kW) ayaa qalab koronto oo 1000kVA ah uu taageeri karaa?
Iyada oo la adeegsanayo aqoonta aasaasiga ah ee kor ku xusan, hadda waxaan si cad oo sax ah uga hadli karnaa su'aasha ugu muhiimsan ee maqaalkan.
Awoodda transformer-ka waxaa lagu cabbiraa kVA (kilovolt-amperes), halka isticmaalka korontada ee qalabka korontada lagu cabbiro kW (kilowats). Kala soocidda ugu muhiimsan waxay ku jirtaa xaqiiqda ah in xisaabinta awoodda firfircoon (kW) ee qalabku ay u baahan tahay in lagu dhufto awooddeeda muuqata (kVA) iyadoo loo marayo iftiinka awoodda (cosφ). Tusaale ahaan, transformer-ka 1000kVA wuxuu keeni karaa oo keliya wax soo saar buuxa oo ah 1000kW marka uu ku shaqeynayo iftiinka awoodda 1.0. Si kastaba ha ahaatee, gaarista xaaladdan ku habboon (PF = 1.0) waa wax aan macquul ahayn codsiyada dhabta ah.
Marxaladda naqshadeynta, haddii aan hirgelinno magdhowga qodobka korontada si loo gaaro qodobka korontada ee 0.95, wax soo saarka awoodda firfircoon ee qalabka korontadu waa in loo xisaabiyaa 1000 × 0.95 = 950kW. Ogeysiis Muhiim ah: Hay'adaha korontada waxay ku amraan qodobka korontada (PF) ee ≥0.9 si looga fogaado ciqaabaha; si kastaba ha ahaatee, ka badan PF = 1.0 waxay sababi kartaa kor u kaca danabka nidaamka iyo khalkhal gelinta xasilloonida shabakadda.
Transformer-ka 1000kVA wuxuu asal ahaan bixiyaa culays koronto oo 200kW ah. Ka dib marka lagu daro culays cusub oo 600kW ah, wadarta baahida korontada firfircoon waxay gaartaa 800kW, taasoo ku jirta xadka hawlgalka ee badbaadada leh ee la xisaabiyay ee transformer-ka.
Sidaa darteed, transformer-ka 1000kVA oo asal ahaan bixiya 200kW oo culays koronto ah ayaa si ammaan ah u shaqayn kara muddo dheer xitaa ka dib marka lagu daro culays 600kW cusub (wadarta 800kW), iyadoo la bixinayo in qodobka korontada loo hagaajiyo heerka loo baahan yahay.












