Hawlaha iyo Adeegsiga Transformers-ka Saddex-Waji leh ee Saliidda lagu dhex milmay

2025-10-14

Shaqooyinka Muhiimka ah

 

Isbeddelka Danabka iyo Gudbinta Tamarta

 

Isbeddel-sameeyaha Saliidda Ku Jira Saddex-Wajis waxay isticmaalaan soo-kicinta elektaroonigga ah si ay u xoojiyaan ama hoos ugu dhigaan danabka AC, iyagoo u adeegaya qalab muhiim ah nidaamyada korontada si ay ugu xidhaan shabakadaha heerarka danabka ee kala duwan. Tusaale ahaan, waxay kor u qaadaan danabka wax soo saarka matoorka (tusaale ahaan, 6kV ama 10kV) ilaa danabka heerka gudbinta (tusaale ahaan, 220kV ama ka sareeya) si loo gaarsiiyo danabka masaafada dheer ama loo yareeyo danabka sare ilaa danabka heerka qaybinta (tusaale ahaan, 10kV/0.4kV) dadka isticmaala dhammaadka

.

 

Dahaarka iyo Kala-baxa Kulaylka

 

Saliidda Transformer-ku waxay u shaqaysaa sidii dhexdhexaad dahaadh ah iyo wakiil qaboojiye ah:

 

Dahaarka: Xoogga sare ee dielectric-ga ee saliidda (oo aad uga badan hawada) wuxuu ka hortagaa wareegyada gaagaaban ee u dhexeeya wareegyada iyo xudunta, wuxuu soocaa qoyaanka iyo wasakhda, wuxuuna gaabinayaa gabowga dahaarka.

.

 

Qaboojinta: Kuleylka ay keento wareegyada iyo xudunta waxaa loo wareejiyaa saliidda, taas oo si dabiici ah ama iyada oo loo marayo nidaamyada qasabka ah (tusaale ahaan, marawaxadaha, bambooyinka) ilaa hiitarka ama dusha sare ee haanta, iyadoo la ilaalinayo heerkulka hawlgalka ee badbaadada leh (badanaa ≤85°C saliidda lakabka sare)

.

 

Badbaadada iyo Xasilloonida

 

Iska caabinta Wareegga Gaaban: Qaab-dhismeedyada si buuxda u saliidaysan waxay xoojiyaan xoogga farsamada, oo ay weheliyaan gudbinta gaaska iyo hawo-mareenka u adkeysan kara qaraxyada si ay si ammaan ah u sii daayaan cadaadiska inta lagu jiro cilladaha gudaha

.

 

​Xeerarka Danabka: Beddelayaasha tuubooyinka saaran ama ka baxaya waxay hagaajiyaan danabka wax soo saarka (±5% baaxadda) si ay u xasiliyaan isbeddellada shabakadda oo ay keento is-dhexgalka tamarta la cusboonaysiin karo ama isbeddellada culayska

.

 

La Qabsiga Deegaanka

 

Hawlgalka Joogga Sare: Meelaha dhaadheer ee ka badan 3,000 mitir, naqshaduhu waxay ku daraan marawaxadaha qaboojinta ee waaweyn ama kala-baxa kulaylka ee la hagaajiyay si loo magdhabo waxtarka qaboojinta oo yaraada cadaadiska hawada oo hooseeya awgeed.

.

 

Tiknoolajiyada Shaabadaynta: Taangiyada jiingadaha ama kuwa ilaaliya ee ku salaysan kaabsalku waxay yareeyaan taabashada hawada saliidda iyo hawada, waxayna kordhiyaan waqtiyada dayactirka iyo cimriga hawlgalka

.

 

Codsiyada Muhiimka ah

Kaabayaasha Korontada

 

Jiilka & Saldhigyada Hoose: Kor u qaad danabyada xarumaha korontada (tusaale ahaan, 10kV ilaa 220kV) si loogu gudbiyo danabyada iyo hoos u dhigista saldhigyada hoose ee terminalka (tusaale ahaan, 35kV ilaa 0.4kV) si loogu isticmaalo warshadaha/magaalada.

.

 

Isku xirka Shabakadaha: Fududeynta dib-u-qaybinta tamarta ee gobollada oo dhan, iyadoo la hubinayo isku-dheellitirka dhaqdhaqaaqa baahida saadka iyo baahida.

 

Waaxaha Warshadaha iyo Tamarta​

 

Goobaha Saliida iyo Macdanta: Bixi koronto deggan oo loogu talagalay qalabka qodista, qalabka soo saarista, iyo xarumaha fog fog ee jawiyada adag

.

 

Birta iyo Kiimikooyinka: Waxay siisaa koronto koronto sare leh (tusaale ahaan, 10kV/35kV) unugyada elektrooliga, foornada, iyo matoorada waaweyn

.

 

Dhismaha iyo Adeegyada Dadweynaha​

 

Awood Ku-meel-gaar ah: Waxaa lagu rakibay goobaha dhismaha, dhacdooyinka, ama xaaladaha degdegga ah si loo helo qaybinta korontada oo degdeg ah oo la isku halleyn karo

.

 

Gaadiidka Tareenka: Awoodda jiidista korontada (tusaale ahaan, 35kV/1.5kV) ee nidaamyada tareenka dhulka hoostiisa mara iyo kuwa xawaaraha sare leh

.

 

La cusboonaysiin karo & Shabakadaha Caqliga leh​

 

Is-dhexgalka Qorraxda/Dabaysha: Kor u qaad tamarta la cusboonaysiin karo ee danab yar leh (tusaale ahaan, 0.69kV) ilaa heerarka gelitaanka shabagga (tusaale ahaan, 35kV) si loo helo quudin hufan

.

 

Xeerarka Korantada Firfircoon: La qabsiga isbeddelka tamarta la qaybiyo, ilaalinta xasilloonida shabakadda iyada oo loo marayo hagaajinta tuubada waqtiga-dhabta ah

.

 

Horumarka Tiknoolajiyada iyo Shuruudaha Xulashada

Casriyeynta Waxtarka Tamarta​

 

Moodooyinka casriga ah (tusaale ahaan, taxanaha S13/S22) waxay yareeyaan khasaaraha aan rarka lahayn >30% iyada oo loo marayo dahaarka asaasiga ah ee la hagaajiyay (tusaale ahaan, amorphous alloys) iyo naqshadaha wareegga, iyagoo raacaya heerarka GB 20052-2024

.

 

Horumarinta Deegaanka​

 

Saliidaha Baaba'aya: Saliidda macdanta ku beddel esters-ka ku salaysan dhirta (100% baaba'aya, oo leh iftiin ≥350°C) si loo yareeyo khatarta dabka iyo saameynta deegaanka.

.

 

La socodka Caqliga leh: Dareemayaasha IoT ee isku dhafan waxay la socdaan tayada saliidda, heerkulka, iyo dheecaanka qayb ahaan si loo ilaaliyo saadaasha

.

 

​Xeerarka Xulashada​

 

Awoodda: 30kVA ilaa 20,000kVA, oo leh cutubyo waaweyn oo loogu talagalay xamuulka warshadaha

.

 

Qaababka Qaboojinta:

 

ONAN (Salaad Is-qaboojin ah): Awoodo yar (

 

OFAF (Saliid qasab ah/Qaboojiye Hawada): Beddelayaasha awoodda sare leh (>20,000kVA)

.

 

Fasalka Dahaarka: H-class (180°C) oo loogu talagalay deegaannada aadka u daran

.

 

Gunaanad

Isbeddellada saddex-geesoodka ah ee saliidda lagu dhex shubo ayaa weli lama huraan u ah nidaamyada tamarta casriga ah sababtoo ah waxtarkooda, isku hallayntooda, iyo la qabsiga. Hal-abuurka agabka deegaanka u fiican, ogaanshaha caqliga leh, iyo naqshadaha is haysta ayaa la jaanqaadaya yoolalka waara ee caalamiga ah, iyagoo hubinaya muhiimadda joogtada ah ee dadaallada kala-guurka tamarta.