Waa maxay gaashaanka elektaroonigga ah?
Gaashaan koronto-ku-saleysan waa xaashi khafiif ah oo aan birlab ahayn oo gudbisa korontada. Gaashaanku wuxuu noqon karaa naxaas ama aluminium. Xaashidan khafiifka ah waxay dhex martaa wareegyada koowaad iyo kan labaad ee gudbiyaha. Xaashida ku jirta gariirad kasta waxay isku xirtaa hal gudbiye oo ku xiran shasigga gudbiyaha.

Hagaha Gaashaannada Elektrostatic-ka ee Transformer (E-gaash)2.jpg

Maxay sameeyaan gaashaanka elektaroonigga ah ee transformers-ka?
Gaashaannada elektaroonigga ah waxay khalkhalka danabka ee waxyeellada leh ka wareejiyaan gariiradaha transformer-ka iyo elektaroonigga xasaasiga ah ee nidaamyada korontada. Tani waxay ilaalisaa transformer-ka iyo nidaamka ku xiran.
Aan si faahfaahsan u eegno arrintan anigoo ka bilaabaya waxa gaashaanka elektaroonigga ah uu ka ilaaliyo.

Hoos u dhac
Wareegyo badan oo koronto oo casri ah ayaa ku dhaca kor u kaca ku meel gaarka ah iyo buuqa qaabka. Gaashaan E-ga ee dhulka ku yaal ayaa yareeya (yareeya) carqaladayntan.

Hagaha Gaashaannada Elektrostatic-ka ee Transformer (E-gaash)3.jpg

Sawirka kore ee bidixda ku yaal wuxuu muujinayaa koror ku meel gaar ah oo danab ku meel gaar ah. Noocan koror fiiqan oo danabka sahayda ah wuxuu ka yimaadaa qalabka xafiisyada caadiga ah sida kombiyuutarrada ama sawir-qaadayaasha. Kontaroolayaasha sidoo kale waa isha caadiga ah ee koror ku meel gaar ah. Sawirka midig wuxuu muujinayaa tusaale qaylada qaabka ee wareegga korantada. Buuqa qaabka waa wax caadi ah wareegyada elektaroonigga ah. Nidaamyada fiilooyinka aan si fiican u shaqeynin ee leh ilaalinta fiilooyinka aan habboonayn waxay badanaa la kulmaan buuqa qaabka.
Hadda aan eegno sida gaashaanka elektaroonigga ah ula tacaalo carqaladahan.

Xidhiidhka Awoodda
Gaashaan E-ga ee dhulka ku yaal wuxuu yareeyaa isku-xidhka awoodda ee u dhexeeya dabaysha koowaad iyo tan labaad. Halkii uu ku xidhmi lahaa dabaysha labaad, waxay lammaanaysaa dabaysha koowaad ee leh gaashaanka E-ga. Gaashaanka E-ga ee dhulka ku yaal wuxuu bixiyaa waddo is-hortaag yar oo dhulka ah. Khalkhalka danabku wuxuu ka soo jeedaa dabaysha labaad. Tani waxay sidoo kale ka shaqaysaa dhammaadka kale ee isbeddelka (ta labaad ilaa tan koowaad).

Hagaha Gaashaannada Elektrostatic-ka ee Transformer (E-gaash)4.jpg

Koronto-qabadyada ku-meel-gaarka ah iyo buuqa qaabka ayaa dhaawici kara transformers-ka iyo qalabka kale ee korontada. Gaashaan koronto-ku-saleysan oo u dhexeeya gariiradaha danabka sare iyo kuwa danabka hooseeya ayaa yareeya khatarahaas. Tixgelin muhiim ah marka la siinayo koronto elektaroonig ah oo xasaasi ah.

Tusaalooyinka Transformers-ka Isticmaala Gaashaanka Elektiroonigga ah
Beddelayaasha Qorraxda iyo Dabaysha
Khalkhalka iswaafajinta iyo beddelka gaarka ah ee ka yimaada qalabka korantada qoraxda ayaa loo wareejiyaa shabakadda korontada. Khalkhalkan danabku wuxuu abuuraa saameyn la mid ah kicinta hawada ee HV-ga oo quudiya shabakadda. Kororka danab ee ku-meel-gaarka ah ee dhinaca korontada ayaa sidoo kale u gudbi kara qalabka korontada. Dhacdooyinkan danab ee xad-dhaafka ah waxay dhaawici karaan qaybaha xasaasiga ah ee qalabka korontada. Gaashaannada elektaroonigga ah waxay bixiyaan ilaalin labada qalab ee korontada, shabakadda, iyo qalabka korontada.
Baro wax badan oo ku saabsan cabbirka iyo shuruudaha naqshadeynta transformer-ka qoraxda.

Darawalnimo Beddelaha Go'doomintas
Transformers-ka go'doominta darawalka waxaa loo sameeyay inay u adkeystaan ​​​​qalalaasaha danabka soo noqnoqda sare (iswaafajinta). Khalalaasaha noocaas ah waxay ka dhashaan qalabka sida darawallada mootooyinka (ama VFDs). Sidaa darteed ereyga "wadista" magaca. Marka laga soo tago iswaafajinta, darawallada mootooyinka ayaa sidoo kale keeni kara khalkhal kale oo danab ah (sida buuqa qaabka). Halkan waa meesha E-gashigu ka soo galo. Transformers-ka go'doominta darawalka waxaa ku jira ugu yaraan hal E-gashi oo u dhexeeya gariiradaha HV iyo LV. Gaashaanno badan ayaa sidoo kale la isticmaali karaa. Gaashaannada E-ga waxaa la dhigi karaa inta u dhaxaysa gariiradaha gudaha iyo addimada xudunta sidoo kale.
Codsiyada leh khalkhalka danabka (sida kor u kaca ku meel gaarka ah iyo buuqa qaabka) waxay ka faa'iidaystaan ​​​​transformer-ka leh gaashaanka elektaroonigga ah. Gaashaannada elektaroonigga ah waa kuwo aan qaali ahayn, waxayna bixiyaan faa'iido weyn oo ku saabsan maalgashiga halkaas oo arrimaha tayada korontada ay khatar ku yihiin.