I. Hordhac

1.1 Muhiimadda Dhexdhexaadka iyo Sare-Beddelayaasha Danabka

Beddelayaasha danab-sameeyayaasha dhexdhexaadka ah iyo kuwa sare waxay u adeegaan laf-dhabarta nidaamyada gudbinta korontada iyo qaybinta, taasoo suurtogalinaysa beddelidda heerarka danab-sameeyayaasha ee badbaadada leh iyo kuwa hufan si loo daboolo baahiyaha warshadaha, ganacsiga, iyo kaabayaasha dhaqaalaha dadweynaha. Iyada oo ah summad hormuud ka ah warshadaha beddelayaasha danab-sameeyayaasha dhexdhexaadka ah iyo kuwa sare, JZP waxay dhistay sumcad adag oo ku saabsan isku halaynta, hal-abuurka farsamada, iyo xalalka loo habeeyey. Xulashada saxda ah ee u dhaxaysa nooca qalalan iyo Transformer-ka Saliidda lagu dhex milmays waxay si toos ah u saamaysaa xasilloonida nidaamka, badbaadada hawlgalka, kharashyada dayactirka, iyo soo celinta maalgashiga muddada dheer - taasoo ka dhigaysa go'aan muhiim u ah qorsheeyayaasha mashruuca iyo injineerada.

1.2 Ujeeddada Maqaalka

Maqaalkani wuxuu higsanayaa inuu bixiyo qaab-dhismeed dhammaystiran oo ku salaysan xaaladda si loo doorto JZP nooca qalalan ama transformers-ka dhexdhexaadka ah iyo kuwa danab sare leh ee JZP. Iyadoo la falanqeynayo kala duwanaanshaha farsamada, xaaladaha codsiga, iyo kiisaska dhabta ah, akhristayaashu waxay heli doonaan aragtiyo wax ku ool ah si ay ula jaanqaadaan nooca transformer-ka shuruudaha mashruuca gaarka ah, iyagoo hubinaya waxqabadka iyo qiimaha ugu wanaagsan.

II. Dulmar guud oo ku saabsan Gudbiyeyaasha Danab-dhalinta Dhexe iyo Sare ee JZP

2.1 Hordhac ku saabsan Summada JZP

Iyada oo tobanaan sano oo waayo-aragnimo ah ku leh warshadaha qalabka korontada, JZP waxay soo baxday inay tahay bixiye lagu kalsoon yahay oo ah transformers-yada danab-dhexe iyo kuwa sare (kala duwanaanshaha danabka: 10kV-220kV, awoodda: 315kVA-250MVA). Sumcadda waxay ka go'an tahay horumarinta tignoolajiyada, iyadoo isku daraysa agabyada horumarsan, nidaamyada kormeerka caqliga leh, iyo naqshadaha deegaanka u fiican safka alaabta. Transformers-ka JZP waxaa si weyn loogu qaataa shabakadaha korontada, beeraha warshadaha, dhismayaasha ganacsiga, iyo mashaariicda tamarta la cusboonaysiin karo ee adduunka oo dhan, iyagoo kasbanaya aqoonsi hufnaantooda sare, heerka guuldarrada oo hooseeya, iyo u hoggaansanaanta heerarka caalamiga ah (IEC, ANSI, GB).

2.2 Fikradaha Aasaasiga ah ee Transformers-yada Danab-Dhexdhexaadka ah iyo kuwa Sare

Beddelayaasha danab-dhaliyaha dhexdhexaadka ah iyo kuwa danab-dhaliyaha sare waxay ku shaqeeyaan mabda'a kicinta elektromagnetic-ka, iyagoo tamarta korontada u wareejinaya wareegyada heerarka danab-dhaliyaha kala duwan iyagoo ilaalinaya isku-dheellitirka soo noqnoqda. Qaybaha muhiimka ah waxaa ka mid ah xudunta birta (bixinta wadada qulqulka magnetic-ka), wareegyada (samaynta hadda iyo danab-dhaliyaha), nidaamka dahaarka (ka hortagga burburka korontada), iyo qaab-dhismeedka qaboojinta (kala firdhinta kulaylka la soo saaro inta lagu jiro hawlgalka). Nidaamyada korontada, beddelayaashani waxay buuxiyaan farqiga u dhexeeya khadadka gudbinta danab-dhaliyaha sare iyo shabakadaha qaybinta danab-dhaliyaha dhexe, ama u dhexeeya ilaha danab-dhaliyaha dhexe iyo isticmaalayaasha dhammaadka danab-dhaliyaha hooseeya, iyagoo hubinaya sahay koronto oo deggan oo loogu talagalay hawlgallada muhiimka ah.

III. Farqiga Farsamo ee u dhexeeya Nooca Qallalan iyo Beddelayaasha Saliidda lagu shubo

3.1 Naqshadeynta Kuraasta

Transformer Nooca Qalalans waxay leedahay qaab-dhismeed furan ama nus-xiran, oo leh xudunta birta iyo wareegyada oo la soo bandhigay ama lagu ilaaliyo sanduuq aan boodh lahayn. Naqshaddani waxay meesha ka saaraysaa khatarta daadashada saliidda waxayna fududaynaysaa kormeerka muuqaalka. Taas bedelkeeda, transformers-ka saliidda lagu shubo waxay qaataan haan bir ah oo si buuxda loo shaabadeeyey oo lagu buuxiyey saliid dahaadh ah, taasoo siinaysa ilaalin heer sare ah oo ka dhan ah wasakhda dibadda (boodh, qoyaan, gaasaska daxalka) laakiin waxay u baahan tahay tallaabooyin adag oo looga hortagayo daadashada. Transformers-ka nooca qalalan ee JZP waxay isticmaalaan agab u adkaysta daxalka meelaha lagu xiro, halka moodooyinka saliidda lagu shubo ay ku jiraan tignoolajiyada laba-laabka ah si loo xoojiyo cimri dhererka.

3.2 Qaabeynta Rasaasta

Transformers-ka nooca qalalan waxay isticmaalaan bushings caag ah oo silikoon ah, kuwaas oo bixiya waxqabad dahaadh oo heer sare ah, dabacsanaan, iyo iska caabin heerkulka sare (ilaa 155°C). Bushings-yadani waxay ku habboon yihiin deegaannada gudaha oo leh meel xaddidan, maadaama ay ku jiraan meel bannaan oo toosan oo yar. Transformers-yada saliidda lagu dhex geliyo, dhanka kale, waxay isticmaalaan bushings porcelain ah - oo loo yaqaan adkeysigooda, iska caabinta gurguurta, iyo ku habboonaanta codsiyada danab sare leh (ka sarreeya 110kV). Bushings-ka porcelain-ka ee JZP waxay maraan xakameyn tayo adag si loo hubiyo isku halaynta xaaladaha adag ee bannaanka, sida dabaysha xooggan iyo wasakhowga culus.

3.3 Hababka Dahaarka iyo Qaboojinta

Isbeddellada nooca qalalan waxay ku tiirsan yihiin dahaarka resin (tuurista resin epoxy ama ku shubidda cadaadiska faakuumka), kaas oo aan guban karin, is-damin kara, kana xor ah qiiqa sunta ah. Qaboojinta waxaa caadi ahaan lagu gaaraa iyada oo loo marayo isku-xidhka hawada dabiiciga ah (AN) ama qaboojinta hawada qasabka ah (AF) ee moodooyinka awoodda sare leh. Isbeddellada saliidda lagu dhex geliyo waxay isticmaalaan saliidda macdanta ama saliidda ester-ka dabiiciga ah labadaba dahaarka iyo dhexdhexaadka qaboojinta - saliiddu waxay ku wareegtaa taangiga iyo radiators-ka (ama taageerayaasha qaboojinta) si ay u kala diraan kulaylka. Isbeddellada nooca qalalan ee resin-ka lagu dahaadhay ee JZP waxay buuxiyaan heerarka dahaarka heerka F/H, halka alaabada saliidda lagu dahaadhay ay leeyihiin saliid dahaar tayo sare leh oo leh iska caabin oksaydh oo aad u fiican iyo xoog dielectric ah.

3.4 Qiimaynta Awoodda iyo Danabka

Isbeddellada nooca qalalan waxaa guud ahaan loogu talagalay danab dhexdhexaad ah (10kV-35kV) iyo awood dhexdhexaad ah (315kVA-20MVA), taasoo ka dhigaysa kuwo ku habboon codsiyada qaybinta. Awooddooda waxaa xaddidaya hufnaanta kala-baxa kulaylka ee meelaha xiran. Isbeddellada saliidda lagu dhex geliyo waxay daboolaan noocyo ballaaran: danab ilaa 220kV iyo awood ilaa 250MVA, oo u adeega gudbinta danab sare iyo baahiyaha warshadaha ee baaxadda weyn. JZP waxay bixisaa xalal loo habeeyey labada noocba, iyadoo transformers nooca qalalan loo habeeyay isku-dhafka iyo moodooyinka saliidda lagu dhex geliyo ee loo habeeyay awoodda culayska sare iyo xasilloonida muddada dheer.

IV. Shuruudaha Xulashada Ku Salaysan Xaaladda

4.1 Xaaladaha Gudaha

4.1.1 Dhismayaasha Ganacsiga (Suuqyada Ganacsiga, Daaraha Xafiisyada)

Dhismayaasha ganacsigu waxay u baahan yihiin qalab badbaadin meel bannaan, oo dab-badbaadiya oo leh heerarka buuqa hooseeya. Qalab-beddelayaasha nooca qalalan ayaa ah kuwa ugu doorbidan halkan: naqshadooda yar waxay ku habboon tahay qolalka korontada ee dabaqa hoose ama armaajooyinka dabaqa lagu dhejiyo, dahaarka resin-kuna wuxuu meesha ka saarayaa khataraha dabka ee la xiriira daadinta saliidda. Qalab-beddelayaasha nooca qalalan ee JZP waxay ku shaqeeyaan heerarka buuqa ee ka hooseeya 60dB, taasoo hubinaysa jawi raaxo leh oo loogu talagalay dadka deggan. Intaa waxaa dheer, shuruudahooda dayactirka ee hooseeya waxay la jaan qaadayaan baahiyaha hawlgalka ee xarumaha ganacsiga, halkaas oo ay tahay in la yareeyo wakhtiga shaqada.

4.1.2 Goobaha Dadweynaha ee Buuxa (Isbitaallada, Iskuullada, Tiyaatarada)

Badbaadadu waa mid aad muhiim u ah meelaha dadku ku badan yihiin, taasoo ka dhigaysa transformers-ka nooca qalalan lama huraan. Si ka duwan moodooyinka saliidda lagu dhex shubo, ma keenaan khataro dab ama deegaan haddii ay dhacdo cillad dahaarka. Isbitaallada, gaar ahaan, waxay u baahan yihiin koronto aan kala go 'lahayn - transformers-ka nooca qalalan ee JZP oo leh nidaamyada qaboojinta AF waxay ilaaliyaan waxqabadka xasilloon marka ay jiraan culaysyo isbeddelaya, iyagoo taageeraya qalabka caafimaadka ee muhiimka ah. Iskuullada iyo tiyaatarada waxay ka faa'iideystaan ​​​​alaabadooda dahaarka aan sunta ahayn, iyagoo hubinaya u hoggaansanaanta xeerarka amniga ee adag ee goobaha dadweynaha.

4.1.3 Deegaannada Gaarka ah ee Gudaha (Qolka Hoose, Garaashyada Dhulka Hoostiisa)

Qolalka hoose iyo meelaha dhulka hoostiisa mara badanaa waxay la ildaran yihiin hawo-qaadis liidata, qoyaan badan, iyo marin u helid xaddidan. Transformers-yada nooca qalalan waxay ku fiican yihiin xaaladahan: dabayshooda shaabadaysan waxay ka hortagaan nuugista qoyaanka, qaboojinta hawada dabiiciga ahna waxay meesha ka saartaa baahida loo qabo tuubooyinka adag. Transformers-yada nooca qalalan ee JZP waxay ku qalabaysan yihiin dahaadh qoyaan-celin ah iyo qaybo u adkaysta daxalka, iyagoo hubinaya hawlgal la isku halleyn karo oo ka dhaca jawi qoyaan qaraabo ah ilaa 95% (aan isku-ururin). Naqshadooda fudud waxay sidoo kale fududaynaysaa rakibidda meelaha xaddidan.

4.2 Xaaladaha Dibadda

4.2.1 Saldhigyada Madaxa-bannaan

Saldhigyada hoose ee madaxa-bannaan waxay u baahan yihiin isbeddelayaal danab sare leh oo awood weyn leh oo leh waxqabad bannaan oo adag. Isbeddellada ku dhex jira saliidda ayaa halkan ku habboon: naqshadooda haanta ee shaabadaysan waxay ka ilaalisaa qaybaha gudaha roobka, boodhka, iyo heerkulka xad-dhaafka ah, halka qaboojinta saliiddu ay suurtogal ka dhigto kala-baxa kulaylka oo hufan si loo shaqeeyo awood sare (ilaa 250MVA). Isbeddellada ku dhex jira saliidda ee JZP ee saldhigyada hoose waxay leeyihiin khaanadaha u adkaysta cimilada, aaladaha aan qarxin, iyo nidaamyada la socodka khadka tooska ah, iyagoo hubinaya isku halaynta 24/7 meelaha fog ama kuwa adag ee bannaanka.

4.2.2 Dhisme Warshadeed oo Furan

Warshadaha leh meelo bannaan oo bannaan ayaa mudnaanta siiya kharashka waxtarka leh, awoodda rarka badan, iyo dayactirka fudud. Transformers-ka saliidda ku dhex milmay waxay bixiyaan wadarta guud ee kharashka lahaanshaha marka la barbar dhigo moodooyinka nooca qalalan ee loogu talagalay codsiyada awoodda weyn leh (ka sarreeya 20MVA). Qaab-dhismeedkooda qaboojinta ee fudud (baalasha radiator-ka + wareegga saliidda dabiiciga ah) waxay yareeyaan baahiyaha dayactirka, halka naqshadda la hagaajiyay ee JZP ay yareyso khasaaraha tamarta (lumitaan aan culays lahayn ≤ 0.3% awoodda la qiimeeyay). Intaa waxaa dheer, transformers-ka saliidda ku dhex milmay waxaa si toos ah loogu rakibi karaa aasaaska shubka iyada oo aan loo baahnayn meelo gaar ah, iyadoo la badbaadinayo booska iyo kharashyada rakibidda.

4.2.3 Cimilada Kulul iyo Qoyaanka leh

Gobollada leh heerkul sare (ka sarreeya 40°C) iyo qoyaan sare (tusaale ahaan, meelaha kulaylaha), qaboojinta transformer-ka iyo waxqabadka dahaarka ayaa muhiim ah. Transformers-yada saliidda ku dhex milmay ayaa si fiican halkan uga shaqeeya sababtoo ah awoodda kulaylka sare ee saliidda dahaarka, taas oo ilaalisa heerkulka hawlgalka ee deggan xitaa kulaylka daran. Mashaariicda u baahan rakibidda gudaha ee cimilada kulul iyo qoyan, transformers-ka nooca qalalan ee JZP oo leh qaboojinta hawada qasabka ah (AF) ama nidaamyada qaboojinta biyaha (WF) waxay bixiyaan beddel, iyagoo hubinaya in kor u kaca heerkulku uu ku jiro xadka IEC (≤ 100K ee dahaarka fasalka F).

4.3 Xaaladaha Codsiga Gaarka ah

4.3.1 Xarumaha Xogta

Xarumaha xogtu waxay u baahan yihiin isbeddello aad loogu kalsoonaan karo oo leh buuq yar, hufnaan sare, iyo soo kabashada cilladaha degdega ah. Isbeddellada nooca qalalan ayaa loo door bidaa deegaannada xarunta xogta gudaha, maadaama ay meesha ka saaraan khataraha daadashada saliidda waxayna si aamusnaan ah u shaqeeyaan (≤ 55dB). Isbeddellada nooca qalalan ee JZP ee xarumaha xogta waxay leeyihiin khasaaro yar oo aan culays lahayn (≤ 0.25%) iyo awood u adkeysi wareeg oo sare, taasoo hubinaysa sahay koronto oo deggan oo loogu talagalay qalabka IT-ga ee muhiimka ah. Xarumaha xogta ee baaxadda weyn leh ee leh qolalka korontada ee bannaanka, isbeddello saliid lagu dhex geliyay oo leh naqshado buuq yar (oo ku qalabaysan meelo aan dhawaaq lahayn) ayaa sidoo kale la heli karaa, iyagoo bixiya awood sare iyo hufnaan tamar.

4.3.2 Gaadiidka Tareenka iyo Tareenka

Nidaamyada tareenadu waxay u baahan yihiin isbeddello is haysta oo shoog leh oo leh iswaafajin koronto oo heer sare ah (EMC). Isbeddellada nooca qalalan waxay ku habboon yihiin codsiyada saaran ama kuwa wadada dhinaceeda ah sababtoo ah naqshadooda fudud, is haysta, iyo iska caabbinta dahaarka resin ee gariirka (ilaa 3g dardargelinta). Isbeddellada nooca qalalan ee JZP ee gaarka u ah tareenka waxay buuxiyaan heerarka EN 50124-1 ee EMC iyo badbaadada dabka, iyagoo hubinaya in aan wax faragelin ah lagu sameyn nidaamyada xakamaynta tareenka. Qaab-dhismeedkooda shaabadaysan ayaa sidoo kale ka ilaaliya boodhka iyo qoyaanka jawiga tunnelka ama bannaanka tareenka.

4.3.3 Warshadaha Korontada Dabaysha iyo Qorraxda

Warshadaha tamarta la cusboonaysiin karo waxay u baahan yihiin qalab wax ka beddela oo xamili kara culaysyada isbeddelaya, kala duwanaanshaha danabka, iyo cadaadiska deegaanka ee bannaanka. Qalab wax ka beddela saliidda ayaa si weyn loogu isticmaalaa beeraha dabaysha iyo qorraxda sababtoo ah waxtarkooda sare (ilaa 99.7%), awood weyn (ilaa 100MVA), iyo iska caabbinta walxaha dibadda. Qalab wax ka beddela saliidda ee tamarta la cusboonaysiin karo ee JZP waxay leeyihiin awood socod oo danab yar, tignoolajiyada xakamaynta iswaafajinta, iyo dahaarka u adkaysta daxalka ee meelaha xeebaha ama lamadegaanka ah. Warshadaha qorraxda ee yar yar ee leh rakibaadda gudaha, qalab wax ka beddela nooca qalalan waxay bixiyaan beddel yar oo deegaanka u fiican.

V. Daraasado Kiis oo ku saabsan Codsiyada JZP Transformer

5.1 Kiisaska Codsiyada ee Guuleystay

5.1.1 JZP Transformers Nooca Qallalan ee Dhisme Sare ah

Taariikhda Mashruuca: Munaar xafiis oo 50 dabaq ah oo ku taal Shanghai waxay u baahnayd qalab lagu kalsoonaan karo Qaybinta Awoodda xalka qolka korontada ee dabaqa hoose (boos: 8m × 5m), oo leh badbaado dab oo adag iyo shuruudo buuq yar.

Xalka: JZP waxay bixisay saddex isbeddel oo nooca qalalan ah oo ah 10kV/0.4kV (awoodda: 2500kVA midkiiba, dahaarka fasalka F, qaboojinta AN/AF). Naqshadda is haysta ee isbeddelkayaasha (dhererka × ballac × dherer: 2.8m × 1.5m × 2.2m) waxay ku habboon tahay booska xaddidan, halka dahaarka resin uu buuxiyay xeerka dabka ee dhismaha (GB 50016-2014). Hawlgalka buuqa hooseeya (

Natiijooyinka Hawlgalka: Transformers-ku waxay shaqeynayeen muddo 5 sano ah iyagoon wax cillad ah lahayn. Celceliska waxtarka tamarta waa 99.2%, taasoo hoos u dhigaysa kharashyada korontada ee sanadlaha ah 12% marka la barbar dhigo moodooyinka caadiga ah. Jawaab celinta isticmaaluhu waxay muujineysaa dayactir fudud iyo waxqabad deggan inta lagu jiro xilliyada culeyska ugu badan (8:00-18:00 maalintii).

5.1.2 Isbeddellada Saliidda ee JZP ee ku jira Warshad Weyn

Taariikhda Mashruuca: Warshad kiimiko batrool ah oo ku taal Guangdong waxay u baahnayd xal koronto oo danab sare leh oo loogu talagalay khadka wax soo saarka (danabka la qiimeeyay: 35kV, wadarta guud: 80MVA), oo leh rakibaad bannaanka ah iyo shuruudaha hawlgalka 24/7.

Xalka: JZP waxay bixisay afar qalab oo saliid lagu dhex geliyay oo 35kV/6kV ah (awoodda: 20MVA midkiiba, qaboojinta ONAN, dahaarka saliidda macdanta). Qalab-sameeyayaashu waxay lahaayeen qalab wax ka beddela cadaadiska qaraxa, la socodka heerkulka saliidda ee khadka tooska ah, iyo qalab u adkaysta daxalka si ay u adkaystaan ​​heerkulka sare ee warshadda (ilaa 42°C) iyo jawiga boodhka leh.

Natiijooyinka Hawlgalka: Transformers-ku waxay si joogto ah u shaqeynayeen muddo 3 sano ah iyadoo heerka cilladdu ay tahay 0%. Lumitaanka tamarta waa 0.5% awoodda la qiimeeyay, taasoo badbaadinaysa warshadda qiyaastii 1.2 milyan oo kWh oo koronto ah sannadkii. Naqshadeynta shaabadaysan ayaa ka hortagtay daadashada saliidda, taasoo hubinaysa in deegaanka loo hoggaansamo xeerarka maxalliga ah.

5.2 Soo Koobidda Khibradda Codsiga

Xaaladaha kor ku xusan, arrimaha muhiimka ah ee lagu dooranayo qalabka JZP waxaa ka mid ah: isku-hagaajinta hababka dahaarka iyo qaboojinta xaaladaha deegaanka (tusaale ahaan, nooca qalalan ee meelaha gudaha/dabka xasaasiga ah, oo saliid lagu dhex geliyay baahiyaha bannaanka/mugga weyn); isku-dubaridka qiimeynta awoodda iyo danabka shuruudaha rarista; iyo mudnaanta siinta heerarka badbaadada iyo hufnaanta ee khuseeya codsiga (tusaale ahaan, buuqa yar ee dhismayaasha ganacsiga, EMC ee tareenada). Awoodda habaynta JZP - sida nidaamyada qaboojinta ee loo habeeyey, fasallada dahaarka, iyo hawlaha la socodka - waxay hubinaysaa iswaafajinta ugu wanaagsan ee xaaladaha mashruuca ee kala duwan.

VI. Talooyinka Xulashada iyo Taxaddarrada

6.1 Tixgelinta Muhiimka ah ee Qorsheynta Hordhaca ah

  • Shuruudaha Awoodda: Xisaabi awoodda la qiimeeyay, heerka danabka, iyo astaamaha culayska (xasilloon iyo isbeddelaya) si loo go'aamiyo nooca danab-sameeyaha. Culaysyada ka sarreeya 20MVA ama danab ka sarreeya 35kV, danab-sameeyayaasha saliidda ku dhex milmay ayaa kharash badan ku baxaya.
  • Hawada Sare iyo Deegaanka: Qiimee goobta rakibidda (gudaha/dibadda), xaddidaadaha booska, heerkulka, qoyaanka, iyo xeerarka badbaadada dabka. Meelaha gudaha/dadka badan waxay u baahan yihiin transformers nooca qalalan; mashaariicda dibadda/ballaaran waxay ka faa'iidaystaan ​​​​moodooyinka saliidda lagu dhex shubay.
  • Miisaaniyadda iyo Cimriga: Ka fiirso maalgashiga bilowga ah, hufnaanta tamarta, iyo kharashyada dayactirka. Transformers-ka nooca qalalan waxay leeyihiin kharashyo hore oo sarreeya laakiin baahiyo dayactir oo hooseeya; Transformers-ka saliidda lagu dhex shubo waxay bixiyaan kharashyo bilow ah oo hooseeya oo loogu talagalay awoodo waaweyn laakiin waxay u baahan yihiin tijaabin/beddel saliideed oo xilliyeed ah.

6.2 Tixgelinta Dayactirka Kadib Rakibaadda

  • Transformers Nooca Qallalan: Samee kormeer muuqaal ah oo sannadle ah (hagaajin, bushings, marawaxadaha qaboojinta), ka nadiifi boodhka meelaha qaboojinta, iyo tijaabi iska caabbinta dahaarka (≥ 100MΩ at 1kV). Transformers-ka nooca qalalan ee JZP waxay leeyihiin muddo dayactir ah oo ah 2-3 sano si loo hubiyo xudunta iyo kuwa wareega.
  • Beddelayaasha Saliida Ku Jira: Samee muunad saliid ah oo rubuc-biloodle ah (tijaabi xoogga dielectric, biyaha ku jira, iyo aashitada), hubi hiitarka si aad u ogaato xannibaadaha, oo hubi in saliiddu daadatay. JZP waxay ku talinaysaa in saliidda la beddelo 8-10kii sanaba mar ama marka tilmaamayaasha tayada ay ka sarreeyaan xadka IEC.
  • Nidaamyada La Socodka: Maalgeli la socodka caqliga leh (heerkulka, qoyaanka, qayb ka mid ah dheecaanka) ee codsiyada muhiimka ah. Isbeddellada caqliga leh ee JZP waxay isku daraan dareemayaasha IoT, taasoo suurtagelinaysa la socodka waqtiga-dhabta ah ee fog iyo dayactirka saadaalinta.

6.3 La jaanqaadida Qalabka Kale

Hubi in qalabka la doortay uu la jaanqaadi karo qalabka kor u socda (matoorada, khadadka gudbinta) iyo qalabka hoose (qalabka badalka, kuwa wax lagu beddelo). Arrimaha ugu muhiimsan ee iswaafajinta waxaa ka mid ah: heerka xakamaynta danabka (±2.5% ama ±5%), awoodda u adkeysiga wareegga gaaban (≥ 25kA ee 10kV), iyo nooca isku xirka (flange, terminalka fiilada). JZP waxay bixisaa taageero farsamo si loo xaqiijiyo iswaafajinta qalabka dhinac saddexaad, iyadoo la hubinayo is-dhexgalka nidaamka oo aan kala go 'lahayn.

VII. Gunaanad

7.1 Soo Koobidda Qodobbada Muhiimka ah

Kala xulashada noocyada qalalan ee JZP iyo kuwa dhexdhexaadka ah iyo kuwa danab sare leh ee ku dhex jira waxay u baahan tahay hab ku salaysan xaaladda: noocyada qalalan ee ku dhex jira ayaa ugu fiican deegaannada gudaha, kuwa xasaasiga u ah dabka, ama meelaha bannaan (dhismayaasha ganacsiga, xarumaha xogta, tareenada) sababtoo ah ammaankooda, isku-dhafka, iyo buuqa yar; kuwa saliidda ku dhex jira ayaa ku fiican codsiyada bannaanka, kuwa waaweyn, ama kuwa xasaasiga u ah kharashka (saldhigyada hoose, warshadaha, warshadaha tamarta la cusboonaysiin karo) taas oo ay ugu wacan tahay waxtarkooda sare, waxqabadkooda xooggan, iyo waxtarka kharashka. Arrimaha farsamada - fasalka dahaarka, habka qaboojinta, awoodda, iyo qiimeynta danabka - waa inay la jaanqaadaan shuruudaha mashruuca gaarka ah, halka baahiyaha dayactirka iyo iswaafajinta qalabka loo tixgelinayo isku halaynta muddada dheer.

7.2 Aragtida Warshadaha

Warshadaha transformers-ka ee dhexdhexaadka ah iyo kuwa danab sare leh ayaa u soo ifbaxaya hufnaan sare, sirdoon, iyo saaxiibtinimo deegaan. JZP ayaa hormuud ka ah isbeddelkan, iyadoo maalgelin ku sameyneysa cilmi-baarista iyo horumarinta transformers-yada asaasiga ah ee aan lummin ee hooseeya, transformers-yada dabiiciga ah ee ester-ka ku dhex milmay saliidda, iyo nidaamyada kormeerka caqliga leh ee AI-ku shaqeeya. Marka is-dhexgalka tamarta la cusboonaysiin karo iyo magaalooyinka ay sii kordhaan, baahida loo qabo xalalka transformers-ka ee gaarka u ah xaaladda ayaa sii kordheysa—JZP waxay weli ka go'an tahay inay keento badeecooyin cusub oo la isku halleyn karo oo buuxiya baahiyaha isbeddelaya ee macaamiisha adduunka, iyadoo la raacayo heerarka deegaanka iyo badbaadada ee adag.