Dhinaca injineernimada korontada, nidaamka qaybinta wuxuu u adeegaa xiriir muhiim ah oo u dhexeeya gudbinta korontada iyo isticmaalka. Faham qoto dheer oo ku saabsan aqoonta qaybinta, gaar ahaan ku saabsan qalabka wax lagu beddelo, waa lama huraan injineerada korontada iyo farsamoyaqaannada. Qalabka wax lagu beddelo waa qalab qaybinta isku dhafan oo lagu soo ururiyey nidaamyada wareegga gaarka ah, oo isku daraya qalabka aasaasiga ah (tusaale ahaan, basaska, jebinta wareegga) iyo qalabka labaad (tusaale ahaan, gudbinta, mitirrada). Shaqadeeda ugu weyn waa inay xakamayso oo ilaaliso khadadka qaybinta iyo qalabka, iyadoo hubinaysa hawlgalka badbaadada leh ee nidaamyada korontada.

 

Kala-soocidda Switchgear-ka

Qalabka wax lagu beddelo waxaa loo kala saari karaa iyadoo lagu saleynayo shuruudaha codsiga iyo heerarka danab:

 

Qaab-dhismeedka: Noocyada nooca go'an iyo kuwa la la bixi karo (gaari gacan).

 

Heerka Danabka:

 

Qalabka Beddelka Danabka Sare: Waxaa ku jira naqshado go'an iyo kuwa la soo bixi karo.

 

Qalabka Beddelka Danabka Hoose: Waxaa ku jira naqshado go'an iyo kuwa nooca khaanadaha.

 

Qaybaha Qaab-dhismeedka ee Qalabka Beddelka

Switchgear-ka wuxuu caadi ahaan ka kooban yahay aagagga shaqada ee soo socda, oo ay go'doomiyeen taarikada birta galvanized si looga hortago wareegyada gaagaaban:

 

Qolka Basbarka: Waxaa ku yaal baararka basaska (kontoroolayaasha basaska).

 

Qolka Jabiyaha Wareega: Waxaa ku jira jabiyaha wareegga ugu weyn.

 

Qolka Xakamaynta Sare (Qolka Qalabka): Qalabka gudbinta guryaha, mitirrada, iyo aaladaha xakamaynta.

 

Qolka Quudinta: Wuxuu isku xiraa quudiyeyaasha baxaya.

 

Qaybaha Muhiimka ah ee Gudaha:

 

Baararka basaska (koronto-qaadayaasha basaska)

 

Jeermisyada wareegga

 

Gudbinta Caadiga ah

 

Aaladaha ilaalinta ee isku dhafan

 

Mitirro

 

Beddelayaasha go'doominta

 

Tilmaamayaasha

 

Beddelayaasha dhulka

 

Qaybaha Shaqada ee Switchgear-ka

1. Golaha Wasiirada ee soo socda (Golaha Wasiirada ee soo galaya)

Doorka: Waxay korontada ka heshaa shabakadda waxayna u qaybisaa qalabka xiga iyada oo loo marayo qalabka jebiya wareegyada, CTs (Transformers-ka hadda jira), iyo PTs (Beddelayaasha Danabka).

 

Muhiimad: Waxay u shaqeysaa sida is-dhexgalka ugu weyn ee isku xirka shabakadda.

 

2. Golaha Wasiirada ee xilka ka degaya (Golaha Qaybinta)

Doorka: Waxay korontada ka qaybisaa baska ilaa khadadka shaqsiga ah ee baxaya, iyadoo hubinaysa in la helo sahay deggan oo loogu talagalay qalabka isticmaalaha ugu dambeeya.

 

3. Golaha Isku-xidhka Basbar​

Doorka: Wuxuu isku xiraa laba qaybood oo bas-bas ah, isagoo taageeraya nidaamyada bas-ka-hal-bas ah oo qayb ahaan loo qaybiyay ama laba-bas ah si loo helo dabacsanaan hawlgal.

 

4. Golaha wasiirada (PT)Transformer-ka Suurtagalka ah Golaha wasiirada)

Doorka: Waxay la socotaa danabka baska waxayna fududeysaa nidaamyada ilaalinta. Waxaa lagu qalabeeyay PTs, badhamada go'doominta, fiyuusyada, iyo qalabka xakamaynta kororka.

 

5. Go'doominta Golaha Wasiirada

Doorka: Waxay bixisaa meel goyn ah oo muuqata oo loogu talagalay dayactirka, ka go'doominta basaska ama qalabka ilaha korontada. Waxay u baahan tahay isku xidhka jabka wareegga si looga hortago hawlgal shil ah.

 

6. Golaha Magdhawga Kondensarka

Doorka: Waxay hagaajisaa awoodda waxayna yareysaa qashinka tamarta iyada oo loo marayo magdhowga awoodda falgalka ah.

 

7. Golaha Mitirka​

Doorka: Waxay cabbirtaa isticmaalka tamarta (kWh) iyadoo la adeegsanayo mitirrada, CT-yada, PT-yada, iyo aaladaha kale sida kormeerayaasha culayska.

 

8. Golaha GIS (Qalabka lagu dahaadho Gaaska)

Doorka: Adeegsiga danab sare/awood sare leh ee isticmaalaya gaaska SF6 si loogu dahaadho, hubinta badbaadada iyo isku halaynta la xoojiyay.

 

Qaybaha Muhiimka ah iyo Doorarkooda

​Jabiyaha Wareegga​

​Hawsha: Waxay isku xirtaa/ka saartaa wareegyada xaaladaha caadiga ah waxayna joojisaa qulqulka cilladaha (tusaale ahaan, wareegyada gaagaaban).

 

Dab-demiska Arc-ka: Waxay isticmaashaa warbaahinta sida gaaska SF6, faakiyuumka, ama saliidda si ay u damiso qaansooyinka inta lagu jiro goynta.

 

Damiye-ka-go'a (Jarista)

Shaqada: Si badbaado leh ayuu u go'doomiyaa wareegyada danab-sare leh si loo dayactiro. Ma laha awood jabinaysa hadda; waa in loo isticmaalaa jabiyayaasha wareegga.

 

Fiyuuska​

Shaqada: Waxay ilaalisaa wareegyada iyadoo dhalaalaysa marka qulqulka xad-dhaafka ahi sii jiro, taasoo u baahan beddel qalliinka kadib.

 

Furaha Load

​Shaqada: Waxay joojisaa qulqulka xad-dhaafka ah laakiin ma joojiso wareegyada gaagaaban. Badanaa waxaa lagu daraa fiyuusyada si loo ilaaliyo kororka xad-dhaafka ah ee aasaasiga ah.

 

Beddelaha​

Shaqada: Waxay beddeshaa heerarka danabka iyada oo loo marayo soo-kicinta elektromagnetic-ka. Xuduudaha muhiimka ah waxaa ka mid ah awoodda la qiimeeyay, saamiga danabka, iyo hufnaanta.

 

Gunaanad