2 Xulashada Qaab-dhismeedka Guud ee Xayawaanka Xoolaha

Qaab-dhismeedka PET-ga aad ayuu u kala duwan yahay. Iyada oo ku saleysan tirada marxaladaha beddelka tamarta, waxaa loo kala saari karaa noocyo hal-marxalad ah, laba-marxalad ah, iyo saddex-marxalad ah [7]. Qaab-dhismeedka laba-marxalad ah waxaa ka mid ah kuwa leh basaska DC-ga ee danab sare leh iyo kuwa danab hooseeya, sida ku cad Jaantuska 1aad.

XAYWAANKA PET-yada hal-marxalad ah (Jaantuska 1(a)), soo noqnoqosho dhexdhexaad ah/sare Beddelaha Go'doominta Waxay isku xirtaa beddelayaasha AC/AC labada dhinac. Beddelaha AC/AC ee dhinaca koowaad wuxuu u beddelaa danabka AC ee soo noqnoqda khadka soo gelinta una beddelaa danab AC oo soo noqnoqda sare leh, kaas oo lagu xidho transformer-ka ka dibna dib loogu beddelo danab AC oo soo noqnoqda khadka ah iyadoo la adeegsanayo beddelaha AC/AC ee dhinaca labaad. PET-yada hal-marxalad leh waxay leeyihiin marxalado beddelka oo yar iyo qaybo yar, hufnaan sare, iyo cufnaan awood sare leh. Si kastaba ha ahaatee, la'aanta baska DC waxay ka dhigaysaa kuwo aan ku habboonayn shabakadaha isku-dhafka ah ee AC/DC, xakamaynta kala-goynta awooddana waa mid adag.

PET-yada laba-geesoodka ah waxay leeyihiin bas DC ah oo ku yaal dhinaca danab sare ama hooseeya. Qaab-dhismeedka hal dhinac ee transformer-ka go'doominta wuxuu u eg yahay kan PET-ka hal-marxalad ah, halka dhinaca kalena uu ku xiran yahay baska DC iyada oo loo marayo wareegyada AC/DC ama DC/AC (Jaantuska 1(c) iyo Jaantuska 1(d)). Iyada oo leh isku xiryo DC-ga sare ama hooseeya, PET-yada laba-marxalad ah waxay ku xidhmi karaan shabagyada DC-ga dhexe/sare ee dhinaca danab sare ama nidaamyada PV/kaydinta dhinaca danab hoose. Si kastaba ha ahaatee, awoodda firfircoon ee ay wareejiyaan beddelayaasha labada dhinac ee transformer-ka go'doominta ayaa aad ugu nugul xuduudaha daadinta transformer-ka. Intaa waxaa dheer, capacitor-ka baska DC wuxuu la kulmaa isbeddellada danab ee laba-marxalad-soo noqnoqoshada leh, isbeddellada hadda ee beddelayaashuna waa kuwo waaweyn [7], taasoo ka dhigaysa xakamaynta mid adag.

Saddex-geesoodka PET-yada (Jaantuska 1(b)) waxay leeyihiin basaska DC ee labada dhinac ee danab sare iyo kuwa hoose. Korontada AC ee soo noqnoqda ee xariiqda gelinta waxaa lagu hagaajiyaa bas DC oo danab sare leh iyada oo loo marayo beddelka AC/DC, oo loo habeeyey hirar laba jibbaaran oo soo noqnoqda sare leh, oo lagu xiray dhinaca danab hoose iyada oo loo marayo transformer dhexdhexaad ah/soo noqnoqoshada sare leh, oo loo hagaajiyay bas DC oo danab hooseeya leh, ugu dambayntiina loo rogay danab AC oo soo noqnoqda khadka ah iyada oo loo marayo beddelka DC/AC. Saddex-geesoodka PET-yada waxay ku xidhmi karaan nidaamyada DC-yada danab sare iyo kuwa hoose labadaba. Xakamaynta marxalad kasta oo beddelka ah waa mid madax-bannaan, taasoo sahlaysa kala-goynta iyo xakamaynta magdhowga. Si kastaba ha ahaatee, marxalado badan oo beddelka ah ayaa keena qaab-dhismeedka ugu adag. Sababtoo ah naqshadaynta marxalado badan leh, topologiyada PET-yada saddexda marxaladood ah si fudud ayay u gaaraan inay ku dhacaan dhinaca danab sare iyo inay barbar socdaan dhinaca danab hoose, iyagoo daboolaya baahiyaha codsiga danab dhexdhexaad ah/sare leh. Sidaa darteed, topologiyada saddexda marxaladood ah ayaa ah kuwa ugu badan ee loo isticmaalo cilmi-baarista iyo codsiyada PET-yada danab dhexdhexaad ah/sare leh.

PET-yada ku jira codsiyada danab dhexdhexaad/sare, dhinaca danab hooseeya wuxuu leeyahay heerarka danab hooseeya oo leh xaddidaad yar oo danab qalab ah. Taas bedelkeeda, marxaladda sixitaanka danab sare iyo marxaladda go'doominta dhexdhexaadka ah waxay wajahayaan heerarka danab sare, iyagoo shuruudo adag ku soo rogaya topolojyada iyo aaladaha wareegga. Cilmi-baarista jirta waxay diiradda saareysaa laba jiho: ① Topolojyada cusub iyo hababka xakamaynta ee PET-yada danab dhexdhexaad/sare leh oo ku salaysan qiimeynta danab qalabka jira; ② Topolojyada iyo kontaroolada PET iyadoo la adeegsanayo aaladaha danab sare leh ee cusub, sida aaladaha 10kV SiC [8, 9]. Si kastaba ha ahaatee, aaladaha SiC danab sare leh ayaa wali ku jira marxaladda R&D ee shaybaarka, aaladaha ganacsiguna weli ma buuxin karaan shuruudaha danab. Sidaa darteed, topolojyada badan ee module-ka lagu dhejiyay ama hal module-ka ah ayaa loo isticmaalaa in lagu daboolo shuruudaha danab-gelinta sare. Topolojyada caadiga ah waxaa lagu muujiyay Jaantuska 2, oo lagu falanqeeyay Qaybta 3.