Leave Your Message
Qaybaha Wararka
Wararka La Soo Bandhigay

Dib u Eegista Qaab-dhismeedka iyo Adeegsiga Xakamaynta ee Transformers Elektroonigga ah ee Tamarta Danab Dhexdhexaad ah oo Sare leh III

2025-09-18

3.3 Qaab-dhismeedka Heerarka Badan ee La Xakameeyay

 

Waxaa la muujiyay qaab-dhismeedka heerarka badan ee Barta Dhexdhexaadka ah ee La Xiray (NPC). Marka laga soo tago qaab-dhismeedka NPC ee la Xiray ee diode-ka, qaab-dhismeedka NPC waxaa sidoo kale ku jira nooca kaabsoosha duulaya iyo nooca isku-dhafka ah ee la xiray, iyo kuwo kale. Si kastaba ha ahaatee, sababtoo ah mugga weyn ee kaabsoosha, qaab-dhismeedka NPC wali waxay inta badan isticmaalaan aaladaha beddelashada ee aan firfircoonayn ama firfircoon si loo xiro. Iyadoo la qaadanayo qaab-dhismeedka heerarka badan ee diode-ka la xiray tusaale ahaan, qaab-dhismeedka marxaladda saddex-waji ee dib-u-hagaajinta, lug kasta oo marxaladeed waxay ka kooban tahay transistors-ka beddela ee la jarjaray iyo diodes-ka la xiray, oo ku xiran hal bas DC oo danab sare leh. Suugaanta waxay soo jeedisay qaab-dhismeedka PET-ka hal-waji leh oo leh marxalad dib-u-hagaajin ah iyadoo la adeegsanayo wareeg afar-waji ah oo diode-ka la xiray. Bas DC oo danab sare leh waxaa ku xiga DAB-yada isku-dhafka ah ee la gelinayo, sida lagu muujiyay. Qaab-dhismeedkan waxaa lagu ballaarin karaa qaab-dhismeed saddex-waji ah, tirada heerarka danabkana waa la beddeli karaa iyadoo lagu saleynayo heerarka danabka u adkeysiga qalabka iyo heerka danabka dhinaca danabka sare leh. Sida topology-ga MMC, topology-ga NPC waxaa sidoo kale lagu dabaqi karaa marxaladda go'doominta, iyadoo lagu xirayo baska DC-ga ee danab sare leh iyo Beddelaha Go'doominta, sida lagu muujiyey. Suugaanta waxay ku dabaqay beddele NPC ah oo saddex-heer ah oo diode-ku xiran dhinaca danab sare ee beddelaha resonant LLC, iyagoo ku xaqiijinaya nooca 166kW/2kV ~ 400V. Suugaanta waxay ku dabaqay wareeg NPC ah oo saddex-heer ah oo diode-ku xiran DAB saddex-heer ah, iyadoo gaadhaysa danab DAB oo ku habboon iyo astaamaha hadda jira.

Marka loo isticmaalo topology-ga NPC marxaladda hagaajinta, uma baahna basaska DC ee go'doonsan, taasoo yaraynaysa tirada transformers-ka marxaladda go'doominta. Intaa waxaa dheer, qaab-dhismeedka saddex-geesoodka ah, ma jiro gariir danab laba-xariiq-soo noqnoqoshada ah oo ku yaal baska. Si kastaba ha ahaatee, sababtoo ah topology-ga la xiray wuxuu u baahan yahay tiro badan oo qalab isku xidha, tirada aaladaha isku xidha ayaa kordha marka tirada heerarka ay kordhaan, taasoo ka dhigaysa ballaarinta heerka mid adag oo aan la gaari karin. Marka la eego xakamaynta, hirarka ku qulqulaya capacitor kasta oo bas ah oo ka mid ah beddelaha NPC way kala duwan yihiin, taasoo horseedaysa dheelitir la'aanta danabka capacitor-ka. Topologies-ka NPC ee ka sarreeya saddex heer, ma jiro algorithm isku dheelitiran danab oo wax ku ool ah. Intaa waxaa dheer, waqtiyada hawlgalka ee aan iswaafaqsanayn ee badhamada gudaha iyo dibadda gacmaha waxay horseedaan kuleyl aan sinnayn, kaas oo lagu xallin karo oo keliya iyadoo la beddelayo topology-ga wareegga guud.

 

Dhibaatooyinka badan ee ay keento ballaarinta heerka waxay la macno tahay in topologies-ka NPC lagu dabaqi karo oo keliya heerarka danab dhexdhexaad ah/sare iyada oo loo marayo isku xirka taxanaha qalabka ama isticmaalka aaladaha SiC-ga danab sare leh. Si kastaba ha ahaatee, heerarka danab hooseeya, marka la barbar dhigo hal topology-ga H-bridge, NPC-ga saddex-heer ah wuxuu leeyahay kala bar oo keliya cadaadiska u adkeysiga danab iyo danab ee transistor kasta oo beddela, halka uu soo saarayo heerar danab badan, taasoo keentay shuruudaha shaandhaynta wax soo saarka oo hooseeya. Waxay leedahay faa'iidooyin codsi oo badan sida marxaladda inverter-ka ee dhinaca danab hooseeya ee PET. Tusaale ahaan, suugaantu waxay u adeegsatay NPC-ga saddex-heer ee diode-ka ku xiran sidii marxaladda inverter-ka ee PET si loo wado matoor saddex-heer ah, iyadoo la sameynayo xaqiijin tijaabo ah lana gaarayo waxqabad wanaagsan oo wadista matoorka ah iyo waxqabadka buuqa.