+86 18068001229 Isbarbardhigga Farsamada: Transformer-ka Go'doominta iyo Transformer-ka Caadiga ah
- Ujeeddooyinka Muhiimka ah ee Shaqada
Transformers-yada Caadiga ah
Waxaa ugu horreyn loogu talagalay beddelka danabka (kor-u-qaad/hoos), iyadoo saamiga wareegyada aan sinnayn ee u dhexeeya wareegyada aasaasiga ah/sare. Ujeeddadooda aasaasiga ah waa isbeddelka danabka AC si loo daboolo shuruudaha culayska.
Diiradda saar go'doominta galvanic halkii aad ka beddeli lahayd wax ka beddelka danabka. Iyadoo moodooyinka qaar ay ilaaliyaan saamiga wareegyada 1:1, doorkooda muhiimka ah waa jebinta waddooyinka korantada tooska ah ee u dhexeeya isha iyo culayska si loo hubiyo badbaadada.
- Falsafadda Naqshadeynta
Transformers-yada Caadiga ah
Waxaa lagu dhisay isku xidhka birlabta oo awood u siinaya beddelka danabka. Transformers-ka otomaatiga ah (nooc hoose) waxay wadaagaan wareegyo loogu talagalay naqshad yar laakiin ma laha awoodo go'doomin ah.
Beddelayaasha Go'doominta
Qaabaysan go'doomin laba-wareeg ah oo leh gaashaan elektromagnetic ah. Moodooyinka horumarsan waxay ku jiraan qafisyo Faraday ah si loo xakameeyo buuqa caadiga ah iyo kuwa ku-meel-gaarka ah.
- Tilmaamaha Badbaadada
| Halbeegga | Transformer-ka Caadiga ah | Beddelaha Go'doominta |
| Xoogga Dielectric | 1,000V (caadi ah) | ≥1,500V (IEC 61558-1 waafaqsan) |
| Daadinta Hadda | Ilaa 3.5mA |
|
| Qaabeynta Dhulka | Dhexdhexaad salka ku haya | Dhul sabeynaya ama dhul la xushay |
- Xaaladaha Codsiga
Transformers-yada Caadiga ah
Nidaamyada xakamaynta otomaatiga warshadaha
Ujeeddo guud Qaybinta Awoodda (tusaale ahaan, beddelka 380V → 220V)
Codsiyada xasaasiga ah ee kharashka leh iyada oo aan lahayn shuruudo badbaado oo adag
Beddelayaasha Go'doominta
Qalabka sawir-qaadista caafimaadka (sawir-qaadayaasha MRI/CT)
Qalabka shaybaarka iyo nidaamyada maqalka/muuqaalka
Isku-xirka tamarta la cusboonaysiin karo (kuwa tamarta qoraxda beddela)
- Hirgelinta Farsamada
Dhaqamada Xargaha
Caadi ah: Xiriiro toos ah oo dhexdhexaad ah
Go'doomin: Khadadka PE/N ee gaarka ah oo leh la socodka dahaarka
Waxqabadka EMI
Caadi: U nugul buuqa la sameeyay (50/60Hz harmonics)
Go'doomin: > 60dB saamiga diidmada qaabka caadiga ah (CMRR)
- Heerarka U Hoggaansanaanta
Caadiga ah: IEC 60726-2 (codsiyada warshadaha)
Go'doomin: IEC 61558-1/2 (nidaamyada muhiimka u ah badbaadada), UL 1950 (aaladaha caafimaadka)
Isbarbardhiggan qaabaysan wuxuu iftiiminayaa sida transformers-ka go'doominta ay u bixiyaan faa'iidooyin badbaado oo muhiim ah iyada oo loo marayo dahaarka sare iyo tiknoolajiyada xakamaynta buuqa, halka transformers-ka caadiga ah ay mudnaanta siiyaan isbeddelka danabka ee kharash-ool ah. Xulasho waxay ku xiran tahay shuruudaha badbaadada korontada ee gaarka ah iyo jawiga hawlgalka.