+86 18068001229 01
Transformer-ka Hal-Waji Ku-rakiban—25 kVA
Sharaxaadda Badeecada
JZP waxay ku fiican tahay soo saarista transformers-ka ANSI/IEEE/UL, iyagoo muujinaya xirfad iyo xirfad cajiib ah suuqyada Waqooyiga iyo Koonfurta Ameerika. Waxay bixiyaan transformers-yo hal-waji ah oo 25 kVA ah, kuwaas oo la naqshadeyn karo, la soo saari karo, loona habeyn karo si ay u daboolaan heerarka caalamiga ah ee kala duwan. Ka go'naanta JZP ee heer sare waxay ka dhigaysaa lammaane lagu kalsoonaan karo dhammaan shuruudaha transformers-ka ee Ameerika iyo wixii ka dambeeya.

25kVA 19.92kV Transformer-ka Hal-Waji ah
DL-25/19.92/0.24(0.12), waa qalab isbeddel-sameeye oo hal-waji ah oo loogu talagalay in lagu rakibo tiirarka.
Transformer-ka hal-waji ee 25 kVA ee ku rakiban tiirarka ayaa adeegsada agab tayo sare leh oo aluminium ah oo loogu talagalay qaybaha danab-sare iyo kuwa hoose, isagoo hubinaya waxqabad sare iyo isku hallayn. Iyada oo leh qiime impedance ah oo ah 2%, waxay leedahay koox Vector ah oo Ii0 ah iyo polarity oo ah Subtractive, taasoo kor u qaadaysa waxtarkeeda.
Danabka sare ee transformer-ka oo leh shan heer oo kala duwan oo nidaaminta danabka ah, wuxuu bixiyaa kala duwanaansho heer sare ah, halka heerka xakamaynta danabka ee 19.92kV ± 2 × 2.5% uu hubinayo xasillooni joogto ah xitaa inta lagu jiro isbeddellada.

25kVA 7.2(12.47)kV/4.8(8.32)kV Transformer-ka Hal-waji ah
Transformer-ka hal-waji ee 25 kVA wuxuu leeyahay naqshad laba-geesood ah oo danab sare leh. Tani waxay suurtogal ka dhigaysaa xulasho aan kala go 'lahayn oo danab sare leh oo ka bilaabma 7.2kV ama 4.8 kV, taasoo si sax ah u dabooleysa baahiyaha qalabka culayska kala duwan, iyadoo bixinaysa kala duwanaansho aan la barbar dhigi karin.
Transformer-ku wuxuu ka kooban yahay nidaam qaboojin oo hufan oo ONAN ah, oo lagu kabo saliid macdan ah oo aan PCB lahayn 45#, taasoo hubinaysa badbaadada iyo mas'uuliyadda deegaanka.
Iyada oo la adeegsanayo kooxda vector-ka ee Ii6 ee la isku halleyn karo iyo polarity-ga lagu daro, transformer-ku wuxuu u taagan yahay heerka ugu sarreeya ee waxqabadka iyo isku halaynta. Qalabka ugu muhiimsan waxaa ka mid ah 1 bushing-ka danab sare leh, 3 bushing-ka danab hooseeya, 1 badhanka danab laba-geesoodka ah, 1 gargaar cadaadis, 1 terminal H2 ah, 2 xariijimo naxaas ah, 3 dhul haan ah, 2 lugood oo taageero ah, 2 lugood oo kor u qaada, iyo 6 xarig oo dabool ah, taasoo caddaynaysa naqshadeeda horumarsan iyo wax ku oolnimada.

25kVA 17.32kV Transformer-ka Hal-Waji ah
Transformer-kani wuxuu leeyahay danab aasaasi ah oo ah 17.32 kV iyo danab labaad oo ah 230V, si taxaddar leh ayaa loo farsameeyay si uu u daboolo shuruudaha gaarka ah ee macaamiisha.
Iyada oo naxaas laga sameeyay xudunta, qalabkani wuxuu damaanad qaadayaa waxqabad iyo isku hallayn heer sare ah. Wuxuu ku shaqeeyaa inta jeer ee 50 Hz wuxuuna leeyahay koox Vector ah oo Ii0 ah oo leh polarity dheeri ah, wuxuuna hubiyaa is-dhexgal aan kala go 'lahayn oo ku jira nidaamyada tamarta kala duwan.
Transformer-ka oo leh kala duwanaansho nidaamsan oo ah 17.32kV ± 2 × 2.5%, taasoo suurtogalinaysa soo saarista danab sax ah oo deggan xitaa marka ay jiraan xaalado culays oo kala duwan.

Weydii Hadda!
Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.