+86 18068001229 01
Transformer-ka Hal-Waji Ku-rakiban—37.5 kVA
Sharaxaadda Badeecada
JZP waa soo saaraha hormuudka ka ah transformers-ka oo ay shahaado ka qaateen CSA, UL, iyo cUL. Waxay ku takhasuseen soo saarista transformers-yada hal-waji ah ee tayo sare leh oo 37.5 kVA ah kuwaas oo buuxiya heerarka adag ee ANSI, CSA, IEEE, DOE, iyo IEC. Transformers-yadan waxaa loogu talagalay inay daboolaan codsiyo kala duwan, oo ay ku jiraan adeegyada korontada, meelaha miyiga ah, iyo nidaamyada qaybinta korontada. Iyadoo ay jirto ballanqaad adag oo ku aaddan tayada iyo isku halaynta, transformers-ka JZP waxaa lagu aaminay waxqabad iyo hufnaan heer sare ah, taasoo ka dhigaysa doorasho ku habboon baahiyaha kala duwan ee la xiriira korontada.
JZP Transformer waxay bixisaa transformer 37.5 kVA ah oo la jaan qaadi kara heerarka caalamiga ah ee kala duwan waxaana loo habeyn karaa si uu ugu habboonaado shuruudaha kala duwan. Transformers-keena si guul leh ayaa loogu dhoofiyay dhowr waddan, oo ay ku jiraan Mareykanka, Kanada, Panama, Venezuela, iyo Honduras.
Iyada oo leh awood wax soo saar bille ah oo ah 500+ cutub, waxaan hubineynaa waqti gaarsiin degdeg ah oo ah 5-8 toddobaad. Ballanqaadkayaga tayada wuxuu ka baxsan yahay wax soo saarka, maadaama aan leenahay kooxo xirfadlayaal ah oo rakibaadda iyo dayactirka iibka kadib ah oo ku sugan Ameerika. Tani waxay hubineysaa xallinta dhibaatooyinka degdega ah iyo xallinta dhibaatooyinka aad la kulmi karto.
Hadday tahay shirkad korontada, qaybiye isbeddel-bixiye, ama dhise, waxaad si kalsooni leh u iibsan kartaa isbeddel-sameeyaha hal-waji ee JZP, adigoo og inaad maalgelinayso badeeco la isku halleyn karo oo sumcad leh. La kulan hufnaanta iyo isku halaynta Transformer-ka JZP, oo loogu talagalay inuu daboolo baahiyahaaga gaarka ah.

37.5 kVA 13.8 kV Transformer
DL-37.5/13.8/0.24(0.12), waa qalab-beddele hal-waji ah oo ay soo saartay JZP Transformer, oo lagu dabaqay heerarka IEEE iyo heerka waxtarka DOE 2016. Qalab-beddelekani wuxuu leeyahay awood dhan 37.5kVA, oo leh koronto gelin sare oo ah 13800V iyo wax soo saar danab hooseeya oo ah 240 (120) V. Habka isku xirka waa Ii0, oo leh naqshad kala-goyn ah.
Si gaar ah loogu talagalay macaamiisha Mareykanka, DL-37.5/13.8/0.24(0.12) wuxuu bixiyaa waxqabad iyo isku hallayn heer sare ah. Iyada oo la adeegsanayo khibradda JZP ee naqshadeynta iyo soo saarista transformers-ka, waxaad ku kalsoonaan kartaa transformer-ka inuu si hufan u daboolo baahiyahaaga.

37.5 kVA 14.4 kV Transformer
DL-37.5/14/0.347, waa transformer-ka hal-waji ku rakiban tiirarka. Transformer-kani wuxuu u hoggaansamaa heerarka IEEE wuxuuna leeyahay awood dhan 37.5 kVA. Waxa uu ku qalabaysan yahay bushing-ka danab-sare, laba bushing-ka danab-hooseeya, iyo 5-meelood oo tubbada lagu beddelo, taasoo hubinaysa waxqabad kala duwan oo hufan.

37.5 kVA 19.9 kV Transformer
DL-37.5/19.9/0.24(0.12), waa transformer-ka ku shaqeeya tiirka. Iyada oo leh heer sare oo danab ah oo ah 19920V, waxay ku qalabaysan tahay laba bushings oo danab sare leh iyo saddex bushings oo danab hooseeya leh, taasoo hubinaysa qaybinta korontada oo aan kala go 'lahayn.
Transformer-kan oo qaabaysan oo qaabaysan ayaa si taxaddar leh loo farsameeyay si loo helo hufnaan wanaagsan iyo isku hallayn aan kala go 'lahayn. Waa transformer-ka dusha sare ee 37.5kVA oo hal-waji ah oo loo sameeyay inuu buuxiyo heerka adag ee ANSI C57.12, isagoo hubinaya waxqabad iyo badbaado heer sare ah.

Weydii Hadda!
Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.









