Leave Your Message

138kv 132kv Transformer-ka Korontada

Qiimaynta Danabyada Aasaasiga ah: 132kV, 138kV ama kuwa kale
Qiimaynta Danab Sare: 11/10.5/6.6/6.3kV ama kuwa kale
Baaxadda Tuubooyinka HV: ±8 × 1.25% ama kuwa kale
NOOCA XIRIIRKA: YNd11 ama kuwa kale
NOOCA: transformer-ka saliidda lagu shubay

    Sharaxaadda Badeecada

    138 kV iyo 132 kV Transformer wuxuu ku salaysan yahay Heerka 1. Qeexitaanka GB 6451 iyo shuruudaha farsamo ee transformers-ka tamarta lagu shubo ee saliidda lagu shubo;2. IEC 60076 Transformers-ka Korontada;3. AS NZS 60076 Transformers-ka Korontada;4.CSAC88-16 Transformers-ka Korontada;5. ANSI/IEEE C57.12.00 Heerka IEEE ee Shuruudaha Guud ee Qaybinta, Korontada, iyo Transformers-ka Xakamaynta Dareeraha ah;6. GOST R 52719 Transformers-ka Korontada - Qeexitaanka Guud; 7. EN60076 Transformer-ka Korontada;8. Adeegyada Iibka Kadib ee Deegaanka Waqooyiga Ameerika Koonfurta Ameerika iyo gobollada kale waxay ka jawaabaan baahiyahaaga 24 saacadood gudahood.
    cer
    Shahaadooyinka Transformer-ka 138 kV 132 kV
    Naqshadeynta iyo soo saarista qalabka JZP 138KV 132KV waxay si buuxda u buuxisaa heerarka GB 6451, IEC 60076, AS NZS 60076, CSAC88-16, ANSI/IEEE C57.12.00, GOST R 52719, EN60076. Kooxda injineerinka xirfadeed ee JZP waxay leedahay in ka badan 10 sano oo waayo-aragnimo ah oo ku saabsan naqshadeynta qalabka isbeddelka mashruuca caalamiga ah. Iyada oo loo eegayo baahiyahaaga iyo shuruudahaaga farsamo, ku sii xalka qalabka isbeddelka ugu habboon.
    Transformer-ka 138 kV iyo 132 kV wuxuu ku salaysan yahay Heerka Caadiga ah
    1. GB 6451 Shuruudaha iyo qeexidda farsamada ee loogu talagalay qalabka wax lagu beddelo ee saliidda lagu shubo;
    2. IEC 60076 Transformers-ka Korontada;
    3. AS NZS 60076 Transformers-ka Korontada;
    4.CSAC88-16 Transformers-ka Korontada;
    5. ANSI/IEEE C57.12.00 Heerka IEEE ee Shuruudaha Guud ee Qaybinta, Awoodda, iyo Beddelayaasha Nidaaminaya Dareere-ku-milmay;
    6. GOST R 52719 Transformers-ka Korontada - Tilmaamaha Guud;
    7. EN60076 Transformer-ka Korontada;
    8. Adeegyada Deegaanka ee Iibka Kadib Waqooyiga Ameerika Koonfurta Ameerika iyo gobollada kale waxay ka jawaabaan baahiyahaaga 24 saacadood gudahood.
    Isbeddel kasta oo 132 kV iyo 138kV ah oo JZP ah waa in si adag loo tijaabiyaa iyadoo la raacayo heerarka tijaabada ee u dhigma ka hor inta aan laga bixin warshadda. Ka dib marka tijaabo kasta ay si buuxda u buuxiso shuruudaha u dhigma, waxaa loo diraa macaamiisha si loo xaqiijiyo warbixinta tijaabada isbeddelka. Waa la xirxiri karaa oo la rari karaa.
    Tilmaamaha Isbeddeleyaasha 138kV iyo 132kV

    132kv Heerka Saddex-waji laba wareeg ah oo OLTC ah

    Awoodda La Qiimeeyay

    Danab Sare

    Danab Hoose

    Lumis la'aan (kw)

    Khasaaraha Ku-soo-baxa (kw)

    Ma jiro hadda rarka (%)

    10MVA

    132 kV

    6.3 kV

    11.8

    51.2

    0.82

    12MVA

    138 kV

    6.6 kV

    13.7

    59.5

    0.82

    15MVA

     

    10.5 kV

    16.3

    73.1

    0.76

    20MVA

     

    11 kV

    19.5

    88.4

    0.76

    25MVA

       

    22.7

    105

    0.69

    30MVA

       

    27.4

    126

    0.69

    37.5MVA

       

    32.9

    148

    0.63

    50MVA

       

    38.9

    184

    0.63

    60MVA

       

    46.4

    221

    0.57

    110kv Heerka Saddex-waji laba wareeg ah oo NLTC ah

    Awoodda La Qiimeeyay

    Danab Sare

    Danab Hoose

    Lumis la'aan (kw)

    Khasaaraha Ku-soo-baxa (kw)

    Ma jiro hadda rarka (%)

    10MVA

    132 kV

    6.3 kV

    11.8

    51.2

    0.64

    12MVA

    138 kV

    6.6 kV

    12.4

    59.5

    0.64

    15MVA

     

    10.5 kV

    15

    73.1

    0.59

    20MVA

     

    11 kV

    17.8

    88.4

    0.59

    25MVA

       

    21

    105

    0.54

    30MVA

       

    25

    126

    0.54

    37.5MVA

       

    29.9

    148

    0.56

    50MVA

       

    35.3

    178.5

    0.52

    60MVA

       

    41.9

    221

    0.48

    Weydii Hadda!