+86 18068001229 01
69kV 4200kVA 5250kVA 3 Waji oo Beddelaha Awoodda ah
Sharaxaadda Badeecada

110 kV 115 kV oo ah beddelayaasha awoodda sida waafaqsan heerka
1. GB 6451 Shuruudaha iyo qeexidda farsamada ee loogu talagalay qalabka wax lagu beddelo ee saliidda lagu shubo;
2. IEC 60076 Transformers-ka Korontada;
3. AS NZS 60076 Transformers-ka Korontada;
4.CSAC88-16 Transformers-ka Korontada;
5. ANSI/IEEE C57.12.00 Heerka IEEE ee Shuruudaha Guud ee Qaybinta, Awoodda, iyo Beddelayaasha Nidaaminaya Dareere-ku-milmay;
6. GOST R 52719 Transformers-ka Korontada - Tilmaamaha Guud;
7. EN60076 Transformer-ka Korontada;
8. Adeegyada Deegaanka ee Iibka Kadib Waqooyiga Ameerika Koonfurta Ameerika iyo gobollada kale waxay ka jawaabaan baahiyahaaga 24 saacadood gudahood.
Transformer-ka 115kV
SF11-20000/115 waa qalab koronto oo 115 kV 20 MVA ah, oo ay bixiso JZP Transformer. Qalab-sameeyahan wuxuu u hoggaansamaa heerarka wax-soo-saarka ee adag ee ANSI C57 Std. Waxa uu leeyahay awood koronto oo sare oo ah 115 kV iyo heer hoose oo danab ah oo ah 13.8 kV.
JZP Transformer waxay keentaa waayo-aragnimo badan iyo taariikh la xaqiijiyay oo ku saabsan mashaariicda transformers-ka danab sare leh ee suuqa Mareykanka. Kooxahooda farsamada iyo iibka waxay muujinayaan faham qoto dheer oo ku saabsan xeerarka maxalliga ah iyo u hoggaansanaanta heerarka ANSI, IEEE, iyo CSA. Transformers-ka HV ee Daelim Transformer waxay heleen codsiyo guul leh oo ku saabsan rakibaadyo kala duwan oo ku baahsan Mareykanka, Kanada, Mexico, Australia, Ecuador, iyo waddamo kale.

Astaamaha Transformer-ka 115 kV 20 MVA
Danab: Transformer-kani wuxuu ku shaqeeyaa 115 kV wuxuuna leeyahay awood weyn oo ah 20 MVA.
Kaydinta Saliidda: Waxaa lagu qalabeeyay kaydiye saliid si loo kordhiyo waxqabadka iyo cimri dhererka.
Calaamadda Kooxda Vektorka: Transformer-ku wuxuu raacaa calaamadda kooxda vektorka Dyn1.
Hababka Qaboojinta: Waxay isticmaashaa nidaam qaboojin dabacsan, oo ay ku jiraan hababka ONAN, ONAF1, iyo ONAF2. Qiimaynta awoodda way ku kala duwan yihiin hababkan: 12 MVA oo loogu talagalay ONAN, 16 MVA oo loogu talagalay ONAF1, iyo 20 MVA oo xooggan oo loogu talagalay ONAF2.
Heerarka Dahaarka: Heerka dahaarka danab-sare waxaa lagu dejiyay 550 kV, halka heerka dahaarka danab-hoose uu yahay 110 kV.
Qiimaynta Heerkulka: Transformer-kan waxaa loogu talagalay inuu maareeyo heerkulka ugu badan ee wareega ee 65℃ iyo heerkulka saliidda ugu badan ee kor u kaca 55℃.
Beddelaha Taabashada: Dhinaca HV wuxuu ku faanaa beddele taabasho oo 5-meelood ah oo kala duwan, kaasoo u oggolaanaya shan heer oo nidaamin danab ah oo u dhexeeya ±2×2.5%.
Bushings: Bushings-ka danab-sare iyo kuwa hoose si habboon ayaa loogu rakibay dusha sare.
Qabanqaabiyeyaasha Kororka: Si loo xoojiyo badbaadada iyo ilaalinta, dhinaca danab-qaadayaasha sare waxaa ku qalabaysan saddex qabqablayaal kor u kaca.

110kV 115kV Transformer
Beddelayaasha korontada ee 115kV/110kV waxaa loogu talagalay oo lagu hagaajiyay iyadoo la nuugayo oo la adeegsanayo teknoolojiyada casriga ah gudaha iyo dibadda si loo hagaajiyo xudunta isbeddelka, gariiradda, jirka, raadadka, haanta shidaalka, iyo qaybaha kale, kuwaas oo leh dheecaan yar oo qayb ahaan ah, lumis yar, buuq yar, fudud, iyo isku hallayn sare. Waxqabadkeeda wanaagsan wuxuu kasbaday ammaan sare dadka isticmaala iyo khubarada khuseeya. Badeecadani waxay leedahay astaamaha xasilloonida, dhaqaalaha, iyo ilaalinta deegaanka, waxayna ku habboon tahay warshadaha korontada, saldhigyada hoose, shirkadaha waaweyn ee warshadaha iyo macdanta, iwm.

Tijaabinta iyo Aqoonta
Transformer-ka 115 kV 20 MVA wuxuu maraa tijaabooyin dhammaystiran si loo hubiyo inuu buuxiyo heerarka adag ee ay dejisay ANSI C57. Tijaabooyinkan waxaa ka mid ah:
Cabbirka Dahaarka
Cabbiraadda Saamiga Danabka iyo Kooxda Vektor-ka
Cabbiraadda Cabbiraadaha Wareegga
Tijaabada Danab-soo-noqoshada Korontada ee Isha Gaarka ah
Cabbiraadda Awoodda Bushing iyo Qodobka Kala-baxa Dielectric
Tijaabada Danab-kicinta Iftiinka
Dareeraha Korontada oo la kiciyey iyo Tijaabada Qayb ka mid ah Dareeraha
Cabbiraadda Danabka Impedance iyo Khasaaraha Culayska
Cabbirka Tijaabada Impedance ee Heerka Buuqa ee Zero-Taxane
Tijaabada Cadaadiska Shaabadda Tijaabada Kor u kaca Heerkulka
Cabbiraadda Qalooca Jawaabta Soo Noqnoqoshada Wareegga Wareegga
Imtixaanka Cabbirka Tijaabada Isbeddelka ee Hadda jira ee Tijaabada Cabbirka Polarity
Batarigan tijaabada ah wuxuu hubinayaa in qalabka beddelka ee 115 kV uu u hoggaansamo heerarka ANSI C57 isla markaana uu si buuxda u qalmo, taasoo dammaanad qaadaysa isku hallayntiisa iyo waxqabadkiisa.

Tilmaamaha Beddelaha Awoodda 110kV iyo 115kV
| 110kv Transformer-ka saddex-waji ah oo laba-geesood ah oo ku shaqeeya beddelka culayska | ||||||
| Qiimaynta | Danab Isku Jir ah | Lumis Raad La'aan ah ma Jirto | Lumista Rarka | Hadda ma jiro culays hadda jira | Impendance-gaaban | |
| (kVA) | HW | LV | ||||
| 6300 kVA | 110kV ±8 | 6.3kv | 10 | 36 | 0.8 | 10.5 |
| 8000 kVA | ×1.25% | 6.6 kW | 12 | 45 | 0.8 | |
| 10000 kVA | 10.5kv | 14.2 | 53 | 0.74 | ||
| 12500 kVA | 115kV ±8 | 11kv | 16.8 | 63 | 0.74 | |
| 16000 kVA | ×1.25% | 20.2 | 77 | 0.69 | ||
| 20000 kVA | 24 | 93 | 0.69 | |||
| 25000 kVA | 28.4 | 110 | 0.64 | |||
| 31500 kVA | 33.8 | 133 | 0.64 | |||
| 40000 kVA | 40.4 | 156 | 0.58 | |||
| 50000 kVA | 47.8 | 194 | 0.58 | |||
| 63000 kVA | 56.8 | 234 | 0.52 | |||
| 110kv saddex weji oo saddex wareeg ah oo ku shaqeeya beddelka culayska | ||||||
| Qiimaynta | Danab Isku Jir ah | Lumis Raad La'aan ah ma Jirto | Lumista Rarka | Hadda ma jiro culays hadda jira | ||
| (kVA) | HV(kV) | MV (kV) | LV(kV) | |||
| 6300 kVA | 110kv±8 | 35kv | 6.3kv | 12 | 47 | 0.95 |
| 8000 kVA | ×1.25% | 37kv | 6.6 kW | 14.4 | 56 | 0.95 |
| 10 MVA | 38.5kv | 10.5kv | 17.1 | 66 | 0.89 | |
| 12.5 MVA | 115kv±8 | 11kv | 20.2 | 78 | 0.89 | |
| 16MVA | ×1.25% | 24.2 | 95 | 0.84 | ||
| 20MVA | 28.6 | 112 | 0.84 | |||
| 25MVA | 33.8 | 133 | 0.78 | |||
| 31.5MVA | 40.2 | 157 | 0.78 | |||
| 40MVA | 48.2 | 189 | 0.73 | |||
| 50MVA | 56.9 | 225 | 0.73 | |||
| 63MVA | 67.7 | 270 | 0.67 | |||
Weydii Hadda!
Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.