+86 18068001229 01
225 kVA 34.5kV Transformer-ka 3-Waji ee lagu rakibay suufka
Sharaxaadda Badeecada
JZP Transformer waxay ku faantaa inay soo bandhigto transformer-ka 3-waji ee ku rakiban 225 kVA 34.5kV, kaas oo si gaar ah loogu talagalay nidaamyada qaybinta warshadaha. Iyada oo loo sameeyay heerarka ugu sarreeya, waxay hubinaysaa in koronto deggan loo helo noocyo kala duwan oo adeegsi warshadeed ah.
01020304050607
SADEX WAJI OO BANDHIG AH OO LAGU JIRO ISBEDDEL
Astaamaha Muhiimka ah
Hufnaan iyo Hal-abuur
Codsiyada Beddelaha 225 kVA
| Tilmaamaha Farsamada ee 225 kVA 34.5kV Transformer | |
| AWOOD LA QIIMEYSTAY | 225 kVA |
| QIIMEYNTA DANABKA KORONTO EE AASAASIGA AH | 34500DELTA |
| Danabka Labaad | 600GrdY/347 |
| SOO NOQOSHADA | 60Hz |
| Kooxda Vector | Dyn1 |
| MAADDADA DABACSAN | Aluminium |
| LUMISTA RAADIGA | ≤2350W |
| LAMA LUMIYO CULAYS | ≤650W |
| Danabka IMPEDANCE | 5.75% |
| DHERERKA | ≤1,500m |
| MIDAB | ANSI 70 Cawlan khafiif ah |
| Miisaanka Saliidda ee Dahaarka leh | 1,040 L |
| WADARTA MIISAANKA | 2,300 kg |
| 225 kVA 34.5kV Qalabka Transformer | |
| QOLKA QALABKA | Fiyuuska ELSP |
| ALBAAB DHINAC AH | FIYUUSKA BAYONET |
| Qaybta Baarkinka | TUBTA BEDDEL |
| Daboolka Taangiga | QIYAASTA HEERKA SALIIDDA |
| LV BUSHING (4-god) | WAALKA GARGAARKA CADAADISKA |
| QALABKA GARGAARKA CADAADISKA | CABBIRKA CADAADISKA VUUM-KA |
| BAR COPPER AH OO DHULKA LAGA SAMEEYAY HV | BOOQADA TERMINAL-ka |
| TUSAHA HEERKULKA | Gacanta Albaabka |
| HV BUSHING WELL (35kV) | XIRMO DHULKA KU JIRA |
| Gacanta Baarka Naxaasta ah ee Dhulka lagu Sameeyay | MAGACA MADAXA |
| BEDDELKA LOADBREAKE EE LABA BOOS AH | SUUFYO BIR AH OO DHULKA KU JIRA |
| 1"'Qalabka Daadiga oo leh 3/8" Muunad qaade | Daaqadda IR |
| XIRIIRKA WARAAQAHA SHAAFADDA EE 1" EE KORE EE WAALKA BUUXINTA | SANDUUQ TERMINAL AH |
Astaamaha Muhiimka ah
Daaqadda IR (Daaqadda Infrared-ka)
Transformer kasta waxa uu ku qalabaysan yahay Daaqadaha IR-ga ee labada qaybood ee danab-sare iyo kuwa danab-hoose, taasoo u oggolaanaysa hawl-wadeennada inay sameeyaan baaritaanno kuleyl ah oo infrared ah iyagoon furin albaabada. Naqshaddani waxay hubinaysaa kormeerro ammaan ah oo hufan, taasoo suurtogalinaysa ogaanshaha hore ee meelaha kulul ee iman kara ama arrimaha kulaylka kulul. Iyadoo la aqoonsanayo khataraha sida xad-dhaafka, isku-xirnaanta dabacsan, ama xiriir xun, Daaqadda IR-gu waxay xoojisaa xasilloonida iyo badbaadada hawlgalka transformer-ka.
Aaladaha Ilaalinta Sare
Transformer-ka 225 kVA waxa uu ku qalabaysan yahay noocyo kala duwan oo ah farsamooyin ilaalin oo horumarsan si loo hubiyo badbaadada hawlgalka iyo cimriga dheer ee adeegga, oo ay ku jiraan:
Cabbirka Cadaadiska Faakuumka: Waxaa ku jira 2 xiriir oo digniin ah oo loogu talagalay la socodka cadaadiska waqtiga-dhabta ah, taasoo bixinaysa digniin hore oo ku saabsan arrimaha iman kara.
Qalabka Gargaarka Cadaadiska: Iyada oo lagu qalabeeyay xiriiro, waxay kicisaa calaamad koronto marka la ogaado cadaadis aan caadi ahayn, taasoo ogeysiinaysa hawl wadeennada inay qaadaan tallaabada lagama maarmaanka ah.
Tilmaamaha Heerka Saliidda: Waxay leedahay 2 xiriir oo digniin ah oo digniin bixiya marka heerka saliiddu aanu caadi ahayn, taasoo u suurtagelinaysa hawl wadeennada inay si dhakhso ah u hagaajiyaan heerka saliidda oo ay ilaaliyaan hawlgalka badbaadada leh.
Tilmaamaha Heerkulka Saliidda: Waxaa ku jira 2 xiriir oo digniin ah—mid loogu talagalay calaamadaha digniinta iyo mid loogu talagalay calaamadaha safarka. Haddii heerkulka saliiddu uu ka badan yahay 70°C, nidaamku wuxuu soo saari doonaa digniin; haddii uu ka bato 105°C, transformer-ku si toos ah ayuu u gariiri doonaa, nidaamka la socodkana wuxuu soo diri doonaa calaamad muujinaysa cilladda.
Naqshad Fudud oo Isticmaale-U-habboon & La Socodka Dibadda
Qalabka lagu dhejiyo dibadda iyo tuubada iyo qalabka lagu shubo: Hawl-wadeennadu waxay tijaabin karaan saliidda dahaarka leh waxayna baari karaan qalabka iyagoon isku soo bandhigin qalabka danab-sare iyo kuwa danab-hoose, taasoo kor u qaadaysa badbaadada, hufnaanta, iyo u hoggaansanaanta.
Gaashaanka Ilaalinta Qalabka Gargaarka Cadaadiska: Gaashaanka ilaalinta wuxuu ka hortagaa waxyeelada dibadda, kicinta shilalka, iyo faragelinta arrimaha deegaanka, isagoo hubinaya in qalabka gargaarka cadaadiska uu si sax ah u shaqeeyo wuxuuna yareynayaa khatarta daadashada gaaska. Waxa kale oo uu ka hortagaa wasakhda inay gasho qalabka wax soo saarka, isagoo ilaalinaya nadaafadda iyo xasilloonida muddada dheer.

Hufnaan iyo Hal-abuur
Transformer-ka 225 kVA ee ka socda JZP Transformer waxaa loogu talagalay iyadoo xoogga la saarayo isku halaynta muddada dheer iyo badbaadada. Iyada oo la adeegsanayo daaqadaha infrared-ka, nidaamyada kormeerka caqliga leh, iyo kontaroolada dibadda ee fudud, transformer-ku ma aha oo kaliya inuu hagaajiyo hufnaanta hawlgalka laakiin sidoo kale wuxuu xoojiyaa badbaadada hawlaha dayactirka. Astaamahani waxay ka caawiyaan hawl wadeennada inay si dhakhso ah u ogaadaan oo ay wax uga qabtaan arrimaha iman kara, iyagoo yareynaya waqtiga shaqada oo hubinaya wax soo saar joogto ah.

Codsiyada Beddelaha 225 kVA
Nidaamyada qaybinta korontada warshadaha
Korontada ganacsiga iyo guryaha
Saldhigyada tamarta la cusboonaysiin karo iyo kuwa korontada lagu beddelo
Xarumaha xogta iyo kaabayaasha muhiimka ah
Culaysyada korontada ee baahida sare leh
Gudbiyaha JZP—Hubinta Awood Lagu Kalsoonaan Karo Baahiyahaaga
JZP Transformer waxay ka go'an tahay inay macaamiisha adduunka oo dhan siiso xalal koronto oo tayo sare leh. Iyada oo loo marayo tignoolajiyada horumarsan iyo xakamaynta tayada adag, waxaan hubineynaa sahay koronto oo deggan oo la isku halleyn karo oo loogu talagalay mashaariic warshadeed iyo ganacsi oo kala duwan. Hadday tahay rakibidda qalabka, dayactirka, ama naqshad gaar ah, waxaan bixinnaa adeegyo xirfadeed iyo taageero.

Weydii Hadda!
Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.