+86 18068001229 01
Transformer-ka Hal-Waji Ku-rakiban—50kVA
Sharaxaadda Badeecada
Transformer-ka JZP Transformer ee hal-waji ah oo 50 kVA ah, waxaa shahaado haysta liiska UL waxaana taageeraya warbixinta kormeerka CESI. Iyada oo leh kala duwanaansho ballaaran oo danab ah oo ah 2.4-34.5kV, transformer-ku wuxuu u hoggaansamaa heerar caalami ah oo kala duwan sida ANSI, IEEE, CSA, IEC, iyo DOE, taasoo hubinaysa iswaafajinta caalamiga ah iyo waxqabadka. Iyada oo lagu saleynayo 20 sano oo khibrad ah oo ku saabsan naqshadeynta iyo dhoofinta, kooxda Transformer-ka JZP waxay u qalabaysan tahay inay daboolaan shuruudaha kala duwan, iyagoo bixinaya xalal la beddeli karo oo loogu talagalay transformers-yada gaarka ah. Iyada oo ay ka go'an tahay qanacsanaanta macaamiisha iyo tayada, JZP Transformer waxay bixisaa alaab la isku halleyn karo, hufan, iyo ammaan ah si loo daboolo baahiyaha gaarka ah ee macaamiisha adduunka oo dhan.

13.8 kV 50 kVA Transformer-ka ku rakiban cidhifka
D-50-13.8/0.12-0.24kV, oo ah transformer 50 kVA ah oo ku rakiban tiirar, waxaa si taxaddar leh u soo saaray JZP Transformer, isagoo u hoggaansamaya heerarka IEEE C57.12.20. Iyada oo leh awood 50kVA ah, waxay ku shaqeysaa 13.8 kV dhinaca koowaad waxayna bixisaa 120/240V dhinaca labaad. Transformer-ku wuxuu leeyahay laba bushings oo danab sare leh, saddex bushings oo danab hooseeya, iyo laba xidheyaal si loo xoojiyo waxqabadka iyo badbaadada.
JZP Transformer waxay hubineysaa tayada iyo isku halaynta ugu sareysa ee cutub kasta. Transformers-ka waxaa loogu talagalay inay buuxiyaan shuruudaha gaarka ah ee shabakadda qaybinta korontada ee Guyana, iyagoo hubinaya sahay koronto oo hufan oo joogto ah. Iyada oo ay ka go'an tahay qanacsanaanta macaamiisha, JZP Transformer waxay bixisaa badeecooyin heer sare ah iyo adeeg heer sare ah si loo daboolo baahiyaha korontada ee Guyana.

14.4 kV 50 kVA Transformer-ka Hal-waji ah
D-50-14.4/0.12-0.24 waa transformer-ka hal-waji ah ee 50 kVA. Waxa uu ku shaqeeyaa 24940/14400V (danab sare) iyo 120/240V (danab hoose) oo leh hal HV bushing. Transformer-ku waxa uu leeyahay aluminium duuban oo buuxiya heerarka waxtarka CSA C2.1 iyo CSA 802.1. Waxa uu ku shaqeeyaa 60Hz waxana uu ka samaysan yahay nidaamka qaboojinta ONAN. Transformer-ku waa dahaarka Class A.

16/27.6kV 50 kVA Transformer-ka Hal-Waji ah
D-50-16-27.6kV/347(600Y)V waa qalab gaar ah oo 50 kVA ah oo hal-waji ah oo ku rakiban tiirar, oo loogu talagalay codsiyada gaarka ah. Iyada oo ku shaqaynaysa heerarka danab ee sare ee 16kV iyo 27.6kV, waxay bixisaa danab hoose oo ah 347(600Y)V.
Waxaa naqshadeeyay oo soo saaray JZP Transformer, waxay u hoggaansan tahay heerarka adag ee CSA C802.1 iyo CSA C2.1, taasoo hubinaysa waxqabadka ugu wanaagsan iyo badbaadada. Transformer-ku wuxuu bixiyaa laba ikhtiyaar oo danab sare leh: 16,000V iyo 27,600V, taasoo ka dhigaysa mid aad ugu habboon xaaladaha kala duwan ee qaybinta awoodda. Waxay leedahay bushing-ka danab sare leh, laba bushing-ka danab hooseeya, iyo badhanka laba-geesoodka ah si loo doorto danab fudud.
Awoodaha gaarka ah ee transformer-kan laba-geesoodka ah ee 50kVA ee hal-waji leh ayaa daboolaya baahiyaha korontada ee gaarka ah ee gobolka, iyagoo hubinaya koronto la isku halleyn karo iyo inay buuxiyaan heerarka ugu sarreeya ee warshadaha.

2.4kV 50 kVA Transformer-ka Hal-Waji ah
D-50-2.4kV/120(240)V waa qalab koronto oo 50 kVA ah oo ku rakiban cidhif, hal mar, oo leh danab sare oo 2.4 kV ah iyo danab hoose oo 120V ah, oo si gaar ah loogu talagalay macaamiisha Kanada. Qalab koronto oo kasta wuxuu leeyahay hal qalab koronto oo sare ah iyo saddex qalab koronto oo hooseeya, taasoo wanaajisa isku xirnaanta. Si taxaddar leh loogu naqshadeeyay loona soo saaray, qalabyadan korontada ayaa buuxiya heerarka adag ee CSA, iyagoo hubinaya waxqabad iyo badbaado heer sare ah. Iyada oo ay jirto ballanqaad aan kala go 'lahayn oo ku aaddan heer sare, qalabyadan korontada waxaa loogu talagalay inay daboolaan baahiyaha gaarka ah ee macaamiisha Kanada, iyagoo bixinaya qaybin koronto oo la isku halleyn karo iyo u hoggaansanaanta dhammaan xeerarka warshadaha ee lagama maarmaanka ah.

Weydii Hadda!
Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.