2500kVA Saddex Waji oo lagu rakibay Transformer

Qiimaynta Danabyada Aasaasiga ah: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 ama kuwa kale
Qiimaynta Danab Sare: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v ama kuwa kale
Baaxadda Tuubooyinka HV: ±2 × 2.5% ama kuwa kale
NOOCA XIRIIRKA: Dyn11/YNyn0 ama kuwa kale
NOOCA: Quudinta wareegga/Quudinta jihada
WUXUU AHAA: 30/150 kV
Heerarka: IEEE, CSA, DOE
Codsiga: BESS, Macdanta Crypto, Warshadaha, Tamarta Dabaysha iyo Qorraxda, Dalacsiinta EV
 Qiimaynta Awoodda: 2500 kVA, 2550 kVA, 2.5 MVA
Shahaadada: UL, CUL, CSA, SGS

    Sharaxaadda Badeecada

    JZP Transformer waa soo saare xirfadle ah oo sameeya transformers-yada oo leh liisaska UL iyo shahaadooyinka heerarka danab ilaa 44kV, iyagoo bixiya noocyo dhammaystiran oo transformers-yo UL-shahaadaysan. Sannad kasta, waxaan u dhoofinaa kumanaan transformers-yadan Mareykanka iyo Kanada. Iyagoo ku xeel dheer IEEE/ANSI, CSA, DOE, NEMA, iyo heerar kale, kooxdeenu waxay hubisaa u hoggaansanaanta shuruudaha sharciyeed ee kala duwan. Marka laga soo tago shahaadada UL, waxaan sidoo kale haynaa shahaadooyinka CSA, MF, CESI, iyo warbixinnada tijaabada SGS ee dhinac saddexaad. Iyadoo leh khibrad mashruuc oo ballaaran, waxaan fahamsanahay in mashruuc kastaa uu leeyahay shuruudo gaar ah. Taasi waa sababta aan u bixinno transformers-yada la beddeli karo, taasoo u oggolaanaysa hagaajinta danabyada, awoodda, habka isku xirka, iyo naqshad gaar ah si ay si fiican ugu habboonaato baahiyahaaga. Transformer-ka 2500 kVA pad ku rakiban waxaa loo habeyn karaa si uu ugu habboonaado shuruudaha mashruucaaga. La xiriir Daelim Transformer maanta si aad u hesho xaashida halbeegga, sawirrada, iyo xigashada transformer-ka pad ku rakiban 2500 kVA.
    shahaado01
    shahaado02
    shahaado03
    shahaado04
    shahaado05
    shahaado 06
    shahaado07
    shahaado 08
    shahaado09
    01020304050607

    Tilmaamaha Beddelaha 2500 kVA (2.5 MVA)

    Wejiga Saddex marxaladood Std. ANSI/IEEE Std C57 & DOE 2016 Std
    Qiimaynta Awoodda 2000kVA (2.5MVA) Habayn Quudinta hore/wareegga dhintay
    Ku rakibidda Ku rakib suufka Soo noqnoqoshada 60Hz
    Danab HV 13200/6720V Beddelaha tuubada 5-boos
    Danabka LV 600/347V Awoodda dareeraha 1600L
    GAARI WAA MAXAY 95 kV Wadarta miisaanka 7000kG
    Gaariga LV 30 kV Ma jiro khasaaro culays ah 2500W
    Kooxda Vektorka Gudaha0 Khasaaraha culayska 15000W
    Habka qaboojinta Deji oo jacayl ilaali Impedance 5.75%
    Qalabka Wareega Aluminium Midabka Rinjiga Cagaaran Munsell
    Dareeraha dahaarka Saliid khudaar ah oo baaba'aysa Awoodda @ 65℃ Kor u kaca Heerkulka 2500 kVA
    Qaabka Aasaasiga ah Saddex weji oo shan-tiir ah Hawada Qasabka ah (Taageerayaasha) Midna ma jiro

    Astaamaha Transformer-ka 2500 kVA
    Astaamaha Transformer-ka 2500 kVA
    Transformer-ka ZGSL-H-2500/13.2-0.6 wuxuu leeyahay qiimeyn awoodeed oo ah 2500 kVA (2.5 MVA). Transformer-ka ku rakiban 2500 kVA wuxuu leeyahay qiimeyn danab oo aasaasi ah oo ah 13.2/7.62 kV oo leh xiriir Wye ah, dhul-hoosaad H0 oo danab sare leh, iyo danab labaad oo ah 600Y/347V Wye oo leh dhul-hoosaad H0 oo danab hooseeya leh.

    Transformer-ka ZGSL-H-2500/13.2-0.6 2500 kVA waa mid la isticmaali karo, wuxuuna ku habboon yahay gudaha iyo dibadda labadaba. Transformers-yadani waxay ku qalabaysan yihiin dareere dahaadh ah oo saliidda khudradda ah oo burburin kara waxayna ilaaliyaan heerkulka kor u kaca 65°C. Waxay la socdaan 3 fiyuus oo ELSP ah iyo 3 fiyuus oo bay-o-net ah si loo ilaaliyo, oo ay weheliyaan 3 bushings oo danab sare leh, 3 arresters oo xusulka ah (HV) ah, iyo afar bushings oo danab hooseeya leh, mid walbana leh 6 god. Booska rakibidda terminal-ka danab hooseeya waxaa lagu xoojiyay saxan Paddount ah. Intaa waxaa dheer, transformer-ka 2500 kVA ee ku rakiban pad wuxuu leeyahay badhanka jabka culeyska afar-meelood ah iyo beddelka tuubada shan-meelood ah ee dhinaca danabka sare leh.

    ZGSL-H-2500/13.2-0.6
    ZGSL-H-2500/13.2-0.6 waa transformer saddex-waji ah oo 2500 kVA ah oo leh liis UL ah. Transformer-ka ku rakiban 2500 kVA wuxuu u hoggaansamaa heerka IEEE C57.12.34 wuxuuna u hoggaansamaa xeerarka DOE. Waxaa lagu dhisay fiilooyin aluminium ah waxaana loo habeeyay sidii transformer nooca loo yaqaan 'rop-feed' ee nidaamyada hore ee hore. Habka qaboojinta ee la isticmaalo waa KNAN.

    ZGS-Z-2500(3050)/44/0.6
    ZGS-Z-2500(3050)/44/0.6 waa qalab gaar ah oo 2500 kVA ah oo ku rakiban qalabka hore ee loogu talagalay inuu buuxiyo shuruudaha gaarka ah ee macaamiisha Kanada oo ay samaysay Daelim Transformer. Qalabkan 2500 kVA ee ku rakiban qalabka ayaa u hoggaansan heerarka CSA C227.4 iyo CAN/CSA 802.1. Waxa uu leeyahay danab sare oo ah 44 kV marka la eego qaabaynta Delta iyo danab hoose oo ah 600GrdY/347V.

    Transformer-ku waxa uu ku qalabaysan yahay saliid RAPO oo qudhmi karta oo ah dareere dahaadh ah, waxaana loogu talagalay kor u kaca heerkulka 55°C ama 75°C. Heerka kVA waa 2500 kVA (2.5 MVA) marka heerkulku kor u kaco 55°C iyo 3050 kVA marka heerkulku kor u kaco 75°C.

    ZGS-Z-2500(3050)/44/0.6
    Waxa kala soocaya transformer-kan 2500 kVA waa in danabkiisa hooseeya loogu talagalay inuu ka baxo dhinaca. Intaa waxaa dheer, cabbiraadaha, beddelka qasabadaha, calaamadda magaca, waalka gargaarka cadaadiska, iyo waalka buuxinta sare dhammaantood waxay ku yaalliin dibadda qolka hore. Cabbiraadahani waxay ku qalabaysan yihiin xiriiro waxayna ku xiran yihiin sanduuqa xakamaynta dibadda ee NEMA 4. Cabbirka cadaadiska faakuumka ayaa ku yaal xagga sare ee qolka hore. Bushing-ka danab-sare waa bushing isku dhafan oo leh afar god, dhinaca HV-na waxaa ku qalabaysan saddex qabasho hillaac, mid walbana wuxuu bixiyaa dabool dahaadh ah si loo ilaaliyo fiilooyinka MV. Intaa waxaa dheer, kuleyliyeyaasha ka hortagga uumiga ayaa lagu rakibay qolka hore ee danab-sare si loo helo waxqabad wanaagsan.
    2

    2.5 MVA 3 PH Transformer
    ZGSL-Z-2500/44/4.16(2.4) waa qalab gaar ah oo saddex-waji ah oo radial pad ku rakiban oo 2.5 MVA ah. Heerka danabkiisa aasaasiga ah waa 44,000 Delta V, halka danabkiisa labaadna uu yahay 4160Y/2400 V. Transformer-ku waxa uu ku habboon yahay koox isku xidha danab sare iyo hoose oo DYn1 ah, waxayna u hoggaansan tahay heerka CSA C227.4. Waxay ku faantaa hufnaan tamar oo cajiib ah oo ah 99.37%, iyadoo la raacayo heerka CAN/CSA-802.3. Iska caabbinta transformer-ka ee 85°C waa 5.75%, waxayna bixisaa toddobo heer oo nidaamin danab ah oo loogu talagalay dhinaca danab sare. Iyada oo leh awood saliid oo dahaadh ah oo ah 2000L iyo miisaankeedu yahay 7500 kg, waa qalab muhiim ah.
    2

    2.5 MVA Transformer
    Waxaa xusid mudan, inay ku faanto naqshad ay labada qaybood ee danab sare iyo kuwa hooseba ku yaalliin dhinaca rakibaadda, iyadoo qaybta danab sare leh ay leedahay qol terminal hawo oo si fiican loo dhigay oo ku fidsan saldhiggeeda. Ku darista waalka qalabka iyo agabka si istaraatiiji ah loogu meeleeyay derbiga haanta shidaalka ee dibadda waxay kor u qaadaysaa helitaanka waxayna hubisaa ku habboonaan dheeraad ah, taasoo tusaale u ah naqshadda transformer-ka ee si taxaddar leh loo farsameeyay.
    Transformer-ka Ku rakiban Pad 2550 kVA

    Transformer-ka Ku rakiban Pad 2550 kVA
    ZGSL-H-2550/34.5/0.415 wuxuu matalaa qalab saddex-geesood ah oo adag oo qaab wareeg ah, kaasoo leh qiimeyn awoodeed oo cajiib ah oo ah 2550 kVA. Wuxuu ku fiican yahay awood koronto oo sare oo ah 34.5 kV halka uu keenayo wax soo saar danab oo hooseeya oo ah 415Grd/240V. Waxaa xusid mudan, labadaba dabaylaha danab ee sare (HV) iyo danab hooseeya (LV) waxaa si taxaddar leh looga sameeyay aluminium. Transformer-kan oo leh qiimeyn hufnaan oo ah 99.4% wuxuuna si adag u hoggaansamaa heerka saxda ah ee IEEE Std C57.12.34. Intaa waxaa dheer, ku darista badhanka jabka culeyska afar-geesoodka ah ayaa si weyn u wanaajisa shaqeynta iyo cabbirrada badbaadada.
    2550 kVA Transformer

    2550 kVA Transformer
    Transformer-ka 2550 kVA wuxuu adeegsadaa nidaamka qaboojinta ONAN/ONAF, sidaas darteedna, waxaa ku jira taageerayaal. Marka uu ku shaqeynayo habka qaboojinta ONAN, transformer-ku wuxuu leeyahay qiimeyn awoodeed oo ah 2550 kVA. Si kastaba ha ahaatee, habka qaboojinta ONAF wuxuu qaban karaa qiimeyn awoodeed oo sare oo ah 3300 kVA. Waxaa xusid mudan, transformer-ku wuxuu ku qalabaysan yahay cabbir heerkul saliid ah oo leh xiriiro digniin ah wuxuuna ku xiran yahay armaajo yar oo bir ah oo aan miridh lahayn oo 304 ah. Qaabeyntani waxay u oggolaanaysaa la socodka fog ee xaaladda hawlgalka transformer-ka.

    Taxanaha ZGSL-H-2550/34.5/0.415 wuxuu ka kooban yahay wadar ahaan afar cutub, oo si gaar ah loogu talagalay loona sameeyay macaamiisha Mareykanka, waana liis UL ah si loo buuxiyo heerarka amniga iyo tayada ee adag.

    ZGSL-H-2550/12.47/0.415
    Taxanaha ZGSL-H-2550/12.47/0.415 wuxuu ka kooban yahay dufcad 2550 kVA ah oo ay soo saartay JZP Transformer macaamiisha Mareykanka. Transformers-yadani waa nooca lagu rakibay pad-ka waxayna leeyihiin qaabeyn quudin wareeg ah. Tilmaamaha muhiimka ah ee transformers-yadan waxaa ka mid ah badhanka jabka culeyska afar-meelood ah, beddelka tuubada shan-meelood ah, cabbirada leh astaamo aan la taaban karin, saddex fiyuus oo bay-o-net ah, iyo laba fiyuus oo xaddidaya hadda.
    12

    12.47 kV 2550 kVA Transformer
    Dhinaca danab-yar, waxaa safka ku jira birlab si loogu taageero terminal-ka. Dareeraha dahaarka ee la isticmaalo waa saliidda macdanta ASTM II, oo leh awood 440 gallon. Taangiga waxaa loogu talagalay inuu u adkeysto cadaadiska taangiga ee ugu badan ee togan ee 10 PSI iyo cadaadiska taangiga ee taban ee 8 PSI. Heerka dareeraha waxaa lagu hayaa 10.0 inji laga bilaabo sare ee godka gacanta 25℃, iyadoo isbeddelka heerka uu yahay 0.4 inji 10℃ kasta. Taangiga waxaa loogu talagalay buuxinta faakuumka PSI 7 waxaana lagu qiimeeyay 2550 kVA marka lagu shido 11,847 volts iyadoo la isticmaalayo beddelka tuubada booska 124,700-volt si loo helo danab labaad oo ah 415Y/240. Transformers-yadani ma laha heerar la ogaan karo oo ah PCB (ka yar 2 ppm) wakhtiga wax soo saarka, taasoo hubinaysa badbaadada deegaanka iyo u hoggaansanaanta.
    13

    13.2 kV 2550 kVA Transformer
    Transformer-ka 2550 kVA waa transformer si gaar ah loogu talagalay oo haysta liis UL ah, kaas oo dammaanad qaadaya u hoggaansanaanta heerarka amniga iyo tayada ee adag. Kooxda isku xirka transformer-kan waa Dy1·Dd0, oo bixisa laba hab oo isku xirka oo kala duwan oo loogu talagalay danab hooseeya:

    Xidhiidhka 4160V Wye, terminaalada waxaa ka mid ah X1B, X2B, X3B isku xirka wejiga, X1A, X2A, iyo X3A isku xirka dhexdhexaadka ah. Xidhiidhka 2400V Delta, terminaalada waa sidan soo socota: C1B ilaa X2A, X2B ilaa X3A, iyo X3B ilaa X1A.
    24

    24.94 kV 2550 kVA Transformer
    Dhammaan transformers-yada 2550 kVA ee ku rakiban pad-ka taxanahan waxaa loo dhisay inay buuxiyaan heerka IEEE C57.12.34, iyagoo dammaanad qaadaya tayada iyo waxqabadka heerka sare. Waxay leeyihiin naqshad cunaha dhinac-ku-xiran oo loogu talagalay isku xirka danab-yar, taasoo u oggolaanaysa is-dhexgal aan kala go 'lahayn oo lala yeesho qalabka wax lagu beddelo. Intaa waxaa dheer, badhanka jabka culeyska ee transformers-yadan 2550 kVA waxaa si xariifnimo leh loogu naqshadeeyay qolka cadaadiska hooseeya ee qolka hore, isagoo bixinaya afar boos oo loogu talagalay kala duwanaansho. Beddelaha tuubada wuxuu bixiyaa shan boos, qalabka hagaajinta cadaadiskana waxaa lagu dejiyay 24.94±2×2.5% si loo xakameeyo saxda ah. Caqabadda transformers-yadan ee 85°C waa 5.87%, taasoo hubinaysa hawlgal deggan oo hufan. Intaa waxaa dheer, Heerarka Dahaarka Aasaasiga ah ee Danab-yar iyo Danab-yar (BILs) waxaa lagu qiimeeyay 125kV iyo 30kV, siday u kala horreeyaan, si loo hubiyo waxqabadka dahaarka oo adag.

    Weydii Hadda!

    Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.