35MVA 115kV Transformer-ka Awoodda Saddex-geesoodka ah

Qiimaynta Danabyada Aasaasiga ah: 115kV
Qiimaynta Danab Sare: 13.8kV
Baaxadda Tuubooyinka HV: 115kV ± 8 × 0.625%
NOOCA XIRIIRKA: YNd1
NOOCA: Beddelaha korontada ee tuubada ku shaqeeya
WUXUU AHAA: 450/110kV
Heerarka: IEEE
Codsiga: Tamarta Cusub
Qiimaynta Awoodda: 20,500/27,200/35,000kVA
Habka Qaboojinta: ONAN/ONAF1/ONAF2

    Sharaxaadda Badeecada

    Beddelaha Awoodda 3-da Waji ee 35MVA 115kV, Waa aalad koronto oo casri ah oo loogu talagalay in loogu adeego codsiyada muhiimka ah ee mashaariicda tamarta la cusboonaysiin karo. Waxaa loo dhisay si ay u buuxiso heerarka ugu sarreeya ee waxqabadka, isku halaynta, iyo hufnaanta tamarta, iyadoo hubinaysa hawlgalka ugu wanaagsan ee nidaamyada tamarta caadiga ah iyo kuwa la cusboonaysiin karo labadaba.
    Astaamaha Muhiimka ah & Waxqabadka
    U hoggaansanaanta IEEE C57.12.00: Transformer-ka 35MVA 115kV wuxuu u hoggaansamaa heerarka warshadaha caalamiga ah, isagoo hubinaya tayo sare iyo waxqabad.
    Khasaare Hoose iyo Hufnaan Sare: Loogu talagalay khasaarooyin hoose oo xudunta ah iyo naxaasta ah, transformer-kani wuxuu si weyn u yareeyaa isticmaalka tamarta, isagoo gacan ka geysanaya waaritaanka iyo kharash-oolnimada.
    Qayb ahaan dheecaanka iyo buuqa oo la dhimay: Waxaa loo farsameeyay si loo helo dheecaan yar oo qayb ahaan ah (PD) iyo qiiqa buuqa, waxayna hubisaa hawlgal deggan iyadoo la ilaalinayo xasilloonida muddada dheer.
    Iska caabinta Wareegga Gaaban: Transformer-ku waxa loogu talagalay inuu u adkeysto qulqulka cilladaha badan, taasoo hagaajinaysa badbaadada guud iyo cimri dhererka nidaamka.
    Naqshad aan daadan karin: Iyada oo la adeegsanayo dhisme adag, transformer-kan waxaa loogu talagalay inuu ka hortago daadashada saliidda, kor u qaadida badbaadada deegaanka iyo isku halaynta nidaamka.
    Astaamaha Muhiimka ah & Waxqabadka
    35MVA 115kV Transformer-ka Awoodda
    Agabka Sare iyo Dhismaha

    1. Qalabka Xudunta iyo Xidhmada: Xudunta qalabka wax lagu beddelo waxaa lagu dhisay bir silikoon ah oo heer sare ah, oo si fiican u waarta, iyadoo leh farsamo isku-xidhka tallaabo-wareegga ah oo heer sare ah oo ku taal 45° si loogu helo qulqulka birlabta ugu wanaagsan. Dusha sare waxaa lagu dahaadhay lakab gaar ah oo ka hortagga daxalka, taasoo yaraynaysa khasaaraha aan culayska lahayn iyo yaraynta heerarka buuqa.

    2. Buuqa Yar iyo Waara oo La Kordhiyay: Isku-xidhka gariiradda iyo xudunta waxaa ku jira astaamo naqshadeed oo gaar ah sida xoojinta xudunta iyo isticmaalka fiilooyinka gudbiyaha ee la beddelay, taasoo hubinaysa soo saarista buuqa yar iyo xasilloonida muddada dheer.

    Beddelaha Taabashada ee Rarka Ku Jira (OLTC)
    1. Transformer-ka 35MVA waxa uu ku qalabaysan yahay Beddelaha Tap-ka ee On-Load (OLTC) dhinaca danabka sare, taasoo u oggolaanaysa nidaaminta danabka inta u dhaxaysa 115kV ± 8 × 0.625%.

    2. OLTC waxaa ku jira qalab ilaaliya, tilmaame heerka saliidda, gudbinta Buchholz, iyo neef-mareen is-cusboonaysiiya, dhammaantoodna waxay gacan ka geystaan ​​​​howlgalka badqabka iyo xasilloonida ee transformer-ka.

    Astaamaha Ilaalinta iyo Badbaadada
    1. Ilaalinta Gaaska iyo Kala Duwanaanta: Transformer-ku wuxuu ku qalabaysan yahay ilaalinta gaaska iyo gudbinta ilaalinta kala Duwanaanta si loo hubiyo hawlgal ammaan ah iyo ogaanshaha cilladaha hore.

    2. La socodka Gudbinta: Cutubku wuxuu leeyahay gudbiyeyaal gudaha iyo dibaddaba ah oo kiciya digniinaha isla markaana bilaaba turunturo otomaatig ah haddii la ogaado isbeddello gaas ama saliid oo aan caadi ahayn.

    3. La socodka Heerka Saliidda: Tilmaamayaasha heerka saliiddu waxay la socdaan xaaladda haanta saliidda, iyadoo digniinaha la kicinayo haddii heerka saliiddu ka baxo xadka loo cayimay, taasoo hubinaysa in si fiican loo dayactiro saliidda.
    Cadaadiska Waalka Gargaarka
    Haddii ay dhacdo in gaaska gudaha uu si degdeg ah u koro sababo la xiriira cillado, qalabka wax lagu beddelo waxaa ku qalabaysan qalab yareeya cadaadiska. Nidaamkani wuxuu sii daayaa gaas xad-dhaaf ah, taasoo ka hortagaysa cadaadiska xad-dhaafka ah waxayna u oggolaanaysaa qolka xakamaynta inuu tallaabo degdeg ah qaado isagoo kicinaya safar otomaatig ah.

    La Socodka Heerkulka
    Tilmaamayaasha Heerkulka Saliidda iyo Wareegga: Transformer-ku wuxuu ku qalabaysan yahay dareemayaal si uu ula socdo heerkulka saliidda iyo wareegga. Haddii heerkulku ka bato 95°C, calaamad digniin ah ayaa loo dirayaa qolka la socodka fog. Haddii heerkulku ka bato 105°C, transformer-ku si toos ah ayuu u gariiri doonaa si looga hortago kulaylka iyo waxyeelada iman karta.

    Nidaamka Qaboojinta
    Transformer-ku wuxuu leeyahay nidaam qaboojin oo laba marxaladood ah:

    Marxaladda 1aad: Marwaxadda qaboojinta ee ugu horreysa ayaa shaqeysa marka heerkulka wareeggu uu ka sarreeyo 75°C.

    Marxaladda 2: Marwaxad labaad ayaa shaqeysa marka heerkulku gaaro 80°C.
    Marka heerkulku hoos uga dhaco 75°C, taageerayaashu si toos ah ayay u damiyaan, taasoo hubinaysa qaboojin hufan iyo yareynta isticmaalka tamarta.

    Neef-sameeyaha Is-soo-nooleynaya

    Labada qalab ee ugu muhiimsan ee transformer-ka iyo kuwa lagu keydiyo tuubada waxaa ku qalabaysan qalab neefsasho oo iskiis isu soo celiya (nooca Qualitrol). Qalabka neefsashadu wuxuu isticmaalaa qalab nadiifiya oo ku dhex jira (jeel silica ah) kaas oo nuuga qoyaanka isla markaana dib u soo celiya kuleylinta, taasoo ka hortagaysa qoyaanka iyo hawada inay galaan transformer-ka. Tani waxay hubinaysaa in dahaarku uu qalalan yahay, taasoo taageerta xasilloonida hawlgalka muddada dheer ee transformer-ka.

    Codsiyada
    1. Mashruucyada Tamarta La Cusboonaysiin Karo (Qorraxda, Dabaysha, iwm.)
    2. Qaybinta Korontada Warshadaha
    3. Xasilinta Shabakadaha
    4. Nidaamyada Korontada ee Kalsoonida Sare leh
    35MVA 115kV Transformer-ka Awoodda
    Gunaanad

    Beddelaha Awoodda Saddex-Waji ee 35MVA 115kV waa xal casri ah oo waxqabad sare leh oo loogu talagalay nidaamyada qaybinta awoodda casriga ah, gaar ahaan qaybaha tamarta la cusboonaysiin karo. Iyada oo leh agab horumarsan, astaamo badbaado oo heer sare ah, iyo naqshad badbaadin tamar, waxay bixisaa hufnaan sare, isku hallayn, iyo cimri dheer oo adeeg ah. Badeecadani waxay tusaale u tahay ballanqaadka JZP Transformer ee ah inuu bixiyo xalal cusub oo tayo leh si loo daboolo baahiyaha mustaqbal tamar waara.

    Diyaar ma u tahay inaad mustaqbalka tamarta xoojiso?
    Nala soo xiriir maanta si aad wax badan uga barato sida Transformer-ka Saddex-Waji ee 35MVA 115kV uu u horumarin karo mashaariicdaada tamarta la cusboonaysiin karo iyo hubinta qaybinta korontada oo la isku halleyn karo oo hufan.
    Gunaanad

    Weydii Hadda!

    Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.

    Leave Your Message