Leave Your Message

Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA

Beddelaha korontada waa qayb muhiim ah oo ka mid ah nidaamyada korontada, oo loogu talagalay in si hufan loogu wareejiyo korontada beddelka ah (AC) inta u dhaxaysa wareegyada heerarka danab ee kala duwan. Ku habboon kor u qaadista ama hoos u dhigista danabyada, beddelayaashani waxay hubiyaan qaybinta korontada ee la isku halleyn karo ee shabakadaha tamarta, xarumaha warshadaha, iyo codsiyada ganacsiga. Iyada oo loo farsameeyay waarta iyo waxqabadka, beddelayaashayada korontada waxay buuxiyaan heerarka caalamiga ah (IEC, IEEE) iyagoo mudnaanta siinaya badbaadada, hufnaanta, iyo waaritaanka.

    Xuduudaha alaabta

    Nooca

    Awoodda

    Heerka Danabka

    Qaboojinta

    Codsiga

    Transformer-ka Qaybinta

    1,600 kVA

    11 kV / 400 V

    DHALINYARADA

    Guryaha/warshadaha

    Transformer-ka Awoodda

    500 MVA

    220 kV / 33 kV

    OFAF

    Xarunta gudbinta gobolka

    Beddelaha UHVDC

    ±400 kV / 500 MVA

    ±800 kV HVDC

    Saliid qasab ah

    Shabakadaha qaaradaha

    Transformer-ka Hagaajiyaha

    20 MVA

    33 kV / 1.8 kV × 6-garaac

    Nooca qalalan, hawo-qaboojiye

    Elektroliska Aluminiumka

    Isbeddelka Sare ee Saliidda Cooper ee la dhex geliyay 10001Isbeddelka Sare ee Saliidda Cooper ee la dhex geliyay 10002Isbeddelka Sare ee Saliidda Cooper ee la dhex geliyay 10003
    Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (1)Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (2)Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (3)Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (4)Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (5)
    • Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (1)
    • Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (2)
    • Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (3)
    • Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (4)
    • Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (5)
    • Xalalka Beddelayaasha Awoodda Gaarka ah ≤2500 kVA (6)
    Transformer-ka Saliidda ee Cooper ee la dhex geliyay 01

    sharraxaadda badeecada

    1. Awoodda La Qiimeeyay (MVA/kVA)
    Qeexitaan: Wax soo saarka tamarta joogtada ah ee ugu badan ee transformer-ku bixin karo.
    Kala duwanaanshaha Caadiga ah:
    Beddelayaasha Qaybinta: ≤2,500 kVA (tusaale ahaan, qaybinta terminaalka guryaha ama warshadaha).
    Beddelayaasha Korontada: Kumanaan kVA ilaa dhowr GVA (tusaale ahaan, saldhigyada gudbinta).
    Beddelayaasha Danab Sare (UHV): Isku xirka shabakadda ama isticmaalka warshadaha, ilaa ± 800 kV Beddelayaasha Beddelayaasha HVDC.
    2. Qiimaynta Danabka
    Danabyada soo gelinta/soo saarista:
    Danab Sare (HV): Caadiyan 33 kV ilaa ±1,100 kV​ (tusaale ahaan, shabakadaha gudbinta).
    Danab Dhexdhexaad ah (MV): Caadi ah ​11 kV, 22 kV, 33 kV.
    Danab Hoose (LV): Badanaa 400 V ama 6.6 kV​ (qaybinta dadka isticmaala).

    Codsiyada Gaarka ah:
    Beddelayaasha Hagaajiyaha: Birta/kiimikada, danab ilaa 30 kV+​.
    Beddelayaasha Jiidista Tareenka: Loogu talagalay awoodda tareenada, tusaale ahaan, 27.5 kV ama 1×25 kV.
    3. Soo noqnoqoshada
    Heerka: 50 Hz (Shiinaha/Yurub) ama 60 Hz (Waqooyiga Ameerika).
    Soo noqnoqoshada Gaarka ah: 400 Hz oo loogu talagalay codsiyada duulista/badda.
    4. Nidaamka Qaboojinta
    Saliid lagu shubay:
    ​ONAN​ (Saliid Hawada Dabiiciga ah ee Dabiiciga ah): Qaboojinta qulqulka dabiiciga ah.
    ONAF (Saliid Dabiici ah oo Hawada Lagu Qasbo): Qaboojinta hawada ee qasabka ah si loo helo hufnaan sare.
    Nooca Qallalan: Qaboojiye hawo leh, oo ku habboon meelaha gudaha/dabka xasaasiga u ah (tusaale ahaan, xarumaha xogta).
    Gaaska-Dahaaran (GIS): Dahaarka gaaska SF6, naqshad isku dhafan oo loogu talagalay saldhigyada cufnaanta sare leh.
    5. Nooca Dahaarka
    Saliid ku jirta: Saliid macdan ah ama saliido ku salaysan ester (deegaan ahaan u fiican).
    Nooca Qallalan: Dahaarka Epoxy resin ama dahaarka warqadda Nomex (dab/qarxin uma baahna).
    Gaaska-Dahaaran: SF6 ama gaasas isku dhafan (saldhigyo hoose oo danab sare leh).
    6. Hufnaan​
    Qiimaha Caadiga ah:
    Beddelayaasha Qaybinta: ≥98% (khasaare yar oo aan culays lahayn iyo khasaaro culays).
    Beddelayaasha Awoodda: ≥99% (moodooyinka danab-sare ee aadka u sarreeya waxay gaaraan hufnaan xitaa ka sarreysa).
    Heerarka: U hoggaansan IEC 61620 ama IEEE C57.12 (tusaale ahaan, shuruudaha naqshadaynta EU).
    7. Kooxda Xiriirka
    Farqiga Wajiga: Waxaa loo aqoonsaday Dyn11, Yd11, taasoo muujinaysa xiriirka wejiga ee u dhexeeya wareegyada si loo maareeyo isku-dhafka iyo qulqulka wareegga gaaban.
    8. Danabka Impedance​
    ​Qeexitaan: Boqolleyda hoos u dhaca danabka inta lagu jiro tijaabada wareegga-gaaban, oo ka tarjumaysa awoodda u adkeysiga wareegga-gaaban.
    Qiimaha Caadiga ah: 4–10% (transformers-ka korontada), ≤4% (transformers-ka qaybinta).
    9. Kor u kaca heerkulka​
    Xaddidaadaha: Transformers-yada saliidda ku dhex milmay ayaa badanaa u oggolaanaya kor u kaca heerkulka ≤55 K (saliidda sare ee ku taal 40°C).
    La qabsiga Deegaanka: Gobollada lamadegaanka waxay u baahan yihiin dib-u-habeyn heer sare ah.
    10. Qiimaynta Ilaalinta​
    Lambarka IP-ga:
    IP23: Buufin aan biyuhu ka madhnayn oo leh buufin ka hortagta boodhka.
    IP66/IP68: Si buuxda ayaa looga shaabadeeyay boodhka/biyaha (codsiyada badda/dibadda).
    Deegaanno Gaar ah: Iska caabbinta daxalka milixda ee loogu talagalay isticmaalka xeebaha/biyo-hoosaadka.
    11. Noocyada Gaarka ah​
    Beddelayaasha Hagaajiyaha: Naqshado garaac badan leh (tusaale ahaan, 12/24-pulse) si loo yareeyo iswaafajinta.
    Beddelayaasha Taabashada: Beddelayaasha Taabashada ee Rarka ku jira (OLTC) ee loogu talagalay nidaaminta danabka.
    Transformers-yada Gaarka ah:
    Beddelayaasha Foornada Korontada: Loogu talagalay culeys xad-dhaaf ah oo muddo gaaban ah (tusaale ahaan, dhalaalinta birta).
    Gudbiyeyaasha Zigzag: Nidaamyada dhulka ee dhexdhexaadka ah ee loogu talagalay xakamaynta iswaafajinta.

    Nooca​ Codsiga Qaboojinta Heerka Danabka

    Transformer-ka Qaybinta 1,600 kVA 11 kV / 400 V ONAN Guryaha/warshadaha
    Transformer-ka Korontada 500 MVA 220 kV / 33 kV OFAF Xarunta gudbinta gobolka
    Beddelaha UHVDC ±400 kV / 500 MVA ±800 kV HVDC Saliid qasab ah oo isku xiran shabakadaha qaaradaha
    Beddelaha Hagaajiyaha 20 MVA 33 kV / 1.8 kV × 6-garaac Nooca qalalan, oo hawo lagu qaboojiyey Elektrolysis Aluminium ah
    Transformer-ka Saliidda lagu dhex milmay ee Cooper02Transformer-ka Saliidda lagu dhex milmay ee Cooper03Transformer-ka Saliidda lagu dhex milmay ee Cooper04Transformer-ka Saliidda lagu dhex milmay ee Cooper05

    Maxaad noo dooran lahayd

    JIEZOU POWER, oo ah naqshadeeye xirfadle ah, soo saaraha iyo rakibaha xalka nidaamka korontada adduunka oo dhan, ayaa la aasaasay 1989, waxayna ku fadhidaa 200,000 mitir oo laba jibbaaran.
    JIEZOU POWER, waxay inta badan maamushaa mashaariicda shabakadda korontada, 500KV EPC, warshadda korontada biyaha ee 230KV, saldhig koronto oo 115KV ah, iwm.
    Warshadda JIEZOU POWER waxay soo saari kartaa nooca saliidda iyo nooca qalalan ee transformer-ka qaybinta, ugu badnaan 500KV 480MVA transformer, GIS, switchgear, substation, oo ku salaysan heerka ANSI/IEEE/DOE2016/CSA/IEC60076.
    JIEZOU POWER waxay si isdaba joog ah u heshaa shahaadada ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Ilaa sanadka 2023, shirkadaha iyo warshadaha caalamiga ah waxaa lagu qaybiyaa Mareykanka, Kanada, Dubai, Dominican Republic, Filibiin, warshadaha iyo shirkadaha laanta Shiinaha waxay ku yaalliin magaalada BengBu, magaalada FengYang, magaalada HaiAn, magaalada TaiZhou, magaalada SuZhou, magaalada ShenYang, iyo magaalada FoShan.
    Marka la eego mustaqbalka, aragtida JIEZOU POWER waa in la noqdo bixiyaha xalka nidaamka korontada ugu kalsoonida badan, la xalliyo caqabadaha maaraynta korontada ee ugu degdegga badan adduunka, la dedejiyo u gudubka meeraha ee tamarta la cusboonaysiin karo. Si qof walba u helo nolol kaarboon yar oo dhalaalaya. Si taas loo gaaro, waxaan sameyn doonnaa dadaallo badan.
    Transformer-ka Saliidda lagu dhex milmay ee Cooper06Transformer-ka Saliidda lagu dhex milmay ee Cooper07Transformer-ka Saliidda lagu dhex milmay ee Cooper08Transformer-ka Saliidda lagu dhex milmay ee Cooper09

    Weydii Hadda!

    Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.

    Leave Your Message