Transformers-yada Saddex-Waji ah ee 500kVA ee ku rakiban Suufka Warshadaha

Transformer-ka Saddex-Waji ee 500kVA ee lagu rakibay Pad-ka waa qalab qaybinta korontada oo tayo sare leh oo loogu talagalay beeraha warshadaha, dhismayaasha ganacsiga, iyo mashaariicda kaabayaasha dhaqaalaha. Waxay u beddeshaa danabka dhexdhexaadka ah (11kV) danab hooseeya (400V) iyadoo la adeegsanayo qaboojinta saliidda lagu dhex geliyo (ONAN), taasoo ka dhigaysa mid ku habboon rakibidda bannaanka. Transformer-kani wuxuu isku daraa isku halaynta, dayactirka hooseeya, iyo awoodaha xad-dhaafka ah ee adag si loo hubiyo sahayda korontada oo deggan jawi adag.

    Sifooyinka Dhismaha

    Core
    Xarig bir ah oo silikoon ah oo qabow lagu duubay: Awood sare oo leh dahaar laminated ah si loo yareeyo khasaaraha hadda socda.
    Naqshadeynta saddex-geesoodka ah ee shan-addimood: Waxay yareysaa is-hortaagga eber-taxane waxayna xakameysaa is-waafajinta.
    Dabayl
    Dabayl Danab Sare leh: Nabar bir ah oo leh dahaar warqad Nomex ah si loogu adkeysto danab sare.
    Dabayl Danab Yar: Qaab-dhismeedka dhululubada lakabka badan leh si loo xoojiyo iska caabbinta wareegga-gaaban.
    Taangiga iyo Qaboojinta
    Baalal radiator ah oo la isku dhejiyay: Qaboojinta dabiiciga ah ee convection iyada oo aan lahayn marawaxad dibadeed.
    Naqshad si buuxda loo shaabadeeyey: Waxay ka hortagtaa oksaydhka saliidda iyo wasakhowga.
    Nidaamka Daboolida
    Saliid macdan ah (caadiga ah) ama saliidda ester-ka FR3 (deegaanka u fiican), oo bixisa dahaadh, qaboojin, iyo dabar go'.
    Heerka qayb ahaan u saarista ≤50pC (IEC 60076 waafaqsan tahay).
    Isbeddelka Sare ee Saliidda Cooper ee la dhex geliyay 10001Isbeddelka Sare ee Saliidda Cooper ee la dhex geliyay 10002Isbeddelka Sare ee Saliidda Cooper ee la dhex geliyay 10003
    Waxtar Sare leh-500kVA-Saddex-Waji-Shuban-ku-rakiban-Transformers-ka Warshadaha
    • Waxtar Sare leh-500kVA-Saddex-Waji-Shuban-ku-rakiban-Transformers-ka Warshadaha (1)
    • Waxtar Sare leh-500kVA-Saddex-Waji-Shuban-ku-rakiban-Transformers-ka Warshadaha (2)
    • Waxtar Sare leh-500kVA-Saddex-Waji-Shuban-ku-rakiban-Transformers-ka Warshadaha (3)
    • Waxtar Sare leh-500kVA-Saddex-Waji-Shuban-ku-rakiban-Transformers-ka Warshadaha (4)
    • Waxtar Sare leh-500kVA-Saddex-Waji-Shuban-ku-rakiban-Transformers-ka Warshadaha (5)
    • Waxtar Sare leh-500kVA-Saddex-Waji-Shuban-ku-rakiban-Transformers-ka Warshadaha (6)
    Transformer-ka Saliidda ee Cooper ee la dhex geliyay 01

    Codsiyada

    Beeraha Warshadaha
    Waxay awood siisaa mashiinnada culus, khadadka wax soo saarka (tusaale ahaan, makiinado, wiishash), waxayna taageertaa culayska muddada gaaban.
    Dhismayaasha Ganacsiga
    Waxay qaybisaa korontada nalalka, nidaamyada HVAC, wiishashka, iyo amniga suuqyada waaweyn, hoteellada, iyo xafiisyada.
    Mashaariicda Kaabayaasha​
    Saldhigyada tareenada, warshadaha daaweynta biyaha wasakhda ah, iyo nidaamyada korontada garoonka diyaaradaha.
    Cusbooneysiinta Shabakadaha Miyiga
    Waxay beddeshaa qalabka gaboobay si loo hagaajiyo isku halaynta iyo hufnaanta tamarta.

    Faa'iidooyinka Muhiimka ah

    Kalsooni Sare
    Waxay ka gudubtaa tijaabooyinka u adkeysiga wareegga gaaban ee IEC 60076, iyadoo hubinaysa xasilloonida inta lagu jiro cilladaha shabakadda.
    Taangiga si buuxda loo xiray wuxuu kordhiyaa cimriga saliidda (dayactirka ma laha ilaa 10 sano).
    Waxtarka Tamarta
    Khasaaraha culayska oo hooseeya ayaa yareeya kharashyada hawlgalka, iyadoo la raacayo heerarka IEEE C57.12.
    La Qabsiga Deegaanka
    Waxay ku shaqeysaa heerkul aad u daran (-40℃ ilaa +55℃) iyo meelo sare (≤3,000m).
    Xulashooyinka Caqliga leh
    Waxay taageertaa isdhexgalka IoT oo leh dareemayaasha heerkulka, kormeerayaasha heerka saliidda, iyo digniinaha fog.

    Hubinta Tayada

    Cutub kastaa wuxuu maraa tijaabo adag, oo ay ku jiraan:
    Tijaabooyinka iska caabbinta dahaarka iyo tijaabooyinka danab-qaadista.
    Cabbiraadda khasaaraha rarka iyo lumitaanka rarka oo aan la cabbirin.
    Xaqiijinta u adkeysiga wareegga gaaban.
    Waxaa shahaado siisay ISO 9001, ISO 14001, iyo KEMA si ay u hoggaansamaan shuruucda caalamiga ah.

    Tilmaamaha Xulashada

    Shuruudaha Rarka
    Culays Joogto ah: Xullo transformers-yo lagu qiimeeyay ≥125% culayska ugu badan ee la filayo (tusaale ahaan, 500kVA isticmaalka joogtada ah ee 400kVA).
    Culayska Muddada Gaaban: Codsiyada warshadaha waxay u baahan karaan 150% awood rarid muddo 30 daqiiqo ah.
    Xaaladaha Deegaanka
    Qoyaanka/Buufinta Cusbada: Meelaha xeebaha waxay u baahan yihiin dahaadh ka hortagga daxalka.
    Shuruudaha Booska: Hubi in ≥1.5m ay ka bannaan tahay agagaarada transformer-ka si loo dayactiro.
    U hoggaansanaanta
    Waxay buuxisaa IEC 60076, IEEE C57.12, GB 1094 (Shiinaha), iyo ATEX ee deegaannada khatarta ah.
    Xulashada Saliida
    Saliid Macdan ah: Kharash ahaan u fiican deegaanka caadiga ah.
    Saliidda Ester-ka ee FR3: Dab u adkaysta oo deegaanka u roon meelaha xasaasiga ah (tusaale ahaan, xarumaha xogta).

    Rakibaadda iyo Dayactirka

    Rakibaadda
    Isticmaal saldhig siman oo leh iska caabin dhuleed ≤4Ω.
    Isgoysyada fiilooyinka waxay taageeraan fiilooyin 185mm² ah (hoos ama dhinac laga soo galo).
    Dayactirka Joogtada ah
    Saddexdii biloodba mar: Hubi heerka saliidda, midabka, iyo daadashada.
    Sanadle: Tijaabi iska caabbinta dahaarka (2,500V megohmmeter) oo samee falanqaynta chromatography saliidda.
    Xallinta dhibaatooyinka​
    Kulayl xad dhaaf ah: Kormeer xirmidda hiitarka ama culaysyo aan caadi ahayn.
    Daadinta Qayb ahaan: Isticmaal chromatography saliid si aad u ogaato cilladaha dahaarka gudaha.
    Transformer-ka Saliidda lagu dhex milmay ee Cooper02Transformer-ka Saliidda lagu dhex milmay ee Cooper03Transformer-ka Saliidda lagu dhex milmay ee Cooper04Transformer-ka Saliidda lagu dhex milmay ee Cooper05

    Maxaad noo dooran lahayd

    JIEZOU POWER, oo ah naqshadeeye xirfadle ah, soo saaraha iyo rakibaha xalka nidaamka korontada adduunka oo dhan, ayaa la aasaasay 1989, waxayna ku fadhidaa 200,000 mitir oo laba jibbaaran.
    JIEZOU POWER, waxay inta badan maamushaa mashaariicda shabakadda korontada, 500KV EPC, warshadda korontada biyaha ee 230KV, saldhig koronto oo 115KV ah, iwm.
    Warshadda JIEZOU POWER waxay soo saari kartaa nooca saliidda iyo nooca qalalan ee transformer-ka qaybinta, ugu badnaan 500KV 480MVA transformer, GIS, switchgear, substation, oo ku salaysan heerka ANSI/IEEE/DOE2016/CSA/IEC60076.
    JIEZOU POWER waxay si isdaba joog ah u heshaa shahaadada ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Ilaa sanadka 2023, shirkadaha iyo warshadaha caalamiga ah waxaa lagu qaybiyaa Mareykanka, Kanada, Dubai, Dominican Republic, Filibiin, warshadaha iyo shirkadaha laanta Shiinaha waxay ku yaalliin magaalada BengBu, magaalada FengYang, magaalada HaiAn, magaalada TaiZhou, magaalada SuZhou, magaalada ShenYang, iyo magaalada FoShan.
    Marka la eego mustaqbalka, aragtida JIEZOU POWER waa in la noqdo bixiyaha xalka nidaamka korontada ugu kalsoonida badan, la xalliyo caqabadaha maaraynta korontada ee ugu degdegga badan adduunka, la dedejiyo u gudubka meeraha ee tamarta la cusboonaysiin karo. Si qof walba u helo nolol kaarboon yar oo dhalaalaya. Si taas loo gaaro, waxaan sameyn doonnaa dadaallo badan.
    Transformer-ka Saliidda lagu dhex milmay ee Cooper06Transformer-ka Saliidda lagu dhex milmay ee Cooper07Transformer-ka Saliidda lagu dhex milmay ee Cooper08Transformer-ka Saliidda lagu dhex milmay ee Cooper09

    Weydii Hadda!

    Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.

    Leave Your Message