Beddelayaasha Saliida 220kVA ee Waxtarka Sare leh ee loogu talagalay Codsiyada Culus
Sifooyinka Dhismaha
Core
Xarigyo bir ah oo silikoon ah oo qabow lagu duubay oo leh dahaar lakab ah si loo yareeyo khasaaraha hadda socda.
Naqshad saddex-geesood ah oo shan-lugood ah si loo yareeyo is-hortaagga eber-taxane iyo in la xakameeyo is-waafajinta.
Dabayl
Dabayl koronto oo sare leh: Nabar bir ah oo leh dahaar warqad Nomex ah oo lakabka dhexe ah.
Dabayl Danab Yar: Qaab-dhismeedka dhululubada lakabka badan leh si loo xoojiyo iska caabbinta wareegga-gaaban.
Taangiga iyo Qaboojinta
Naqshadeynta ONAN oo leh wareegga saliidda dabiiciga ah iyo ma jiraan taageerayaal dibadeed, oo ku habboon rakibidda dibadda.
Baallaha radiator-ka ee la isku dhejiyay ayaa lagu dhex daray haanta si loo helo kuleyl hufan.
Nidaamka Daboolida
Saliidda macdanta (ama saliidda ester-ka deegaanka u fiican) waxay bixisaa dahaadh, qaboojin, iyo dabar go'.
Heerka qayb ahaan u saarista ≤50pC (IEC 60076 waafaqsan tahay).




Codsiyada
Qaybinta Korontada Warshadaha
Qaybinta danab dhexdhexaad ah (10kV ilaa 0.4kV) warshadaha, macdanta, iyo warshadaha birta.
Waxay taageertaa culayska muddada gaaban (tusaale ahaan, foornooyinka korontada, shirkadaha cusub ee matoorada).
Dhismayaasha Ganacsiga
Qaybinta korontada ee suuqyada waaweyn, munaaradaha xafiisyada, iyo hoteellada.
Kaabayaasha
Saldhigyada tareenka, garoomada diyaaradaha, iyo warshadaha daaweynta biyaha wasakhda ah.
Meelaha Fog
Si kalsooni leh ayuu ugu shaqeeyaa jawi qoyan, boodh badan, ama jawi heerkulku isbeddelo.
Faa'iidooyinka Muhiimka ah
Kalsooni Sare
Taangiga si buuxda loo xiray wuxuu ka hortagaa oksaydheynta saliidda iyo wasakhowga.
Awood u adkeysiga wareegga gaagaaban oo xooggan (GB/T 1094.5 waafaqsan).
Dayactir Yar
Naqshad aan dayactir lahayn oo leh heerka saliidda waqtiga dhabta ah iyo kormeerka heerkulka.
Kharash-ool ah
Maalgashi bilow ah oo hooseeya iyo khasaarooyin tamar hawlgal oo yar.
Xulashooyinka Deegaanka u Wanaagsan
Waxaa laga heli karaa saliidda ester-ka ee baaba'aya (tusaale ahaan, FR3) si loogu hoggaansamo RoHS.
Tilmaamaha Xulashada
Cutub kastaa wuxuu maraa tijaabo adag, oo ay ku jiraan:
Tijaabooyinka iska caabbinta dahaarka iyo tijaabooyinka danab-qaadista.
Cabbiraadda khasaaraha rarka iyo lumitaanka rarka oo aan la cabbirin.
Xaqiijinta u adkeysiga wareegga gaaban.
Waxaa shahaado siisay ISO 9001, ISO 14001, iyo KEMA si ay u hoggaansamaan shuruucda caalamiga ah.
Tilmaamaha Xulashada
Astaamaha Culayska
Xaqiiji nooca rarka (joogto ah iyo isbeddelaya).
Qiimee shuruudaha xad-dhaafka ah ee muddada gaaban (tusaale ahaan, foornooyinka qaansada korontada).
Xaaladaha Deegaanka
Dhererka ≤1,000 mitir (ka saarista ayaa loo baahan yahay wixii ka sarreeya tan).
Heerkulka deegaanka: -25℃ ilaa +45℃ (qaboojinta oo la xoojiyay gobollada kulaylaha).
U hoggaansanaanta
Wuxuu buuxiyaa GB 1094 (Shiinaha), IEC 60076 (caalami ah), iyo shahaadooyinka gaarka u ah warshadaha (tusaale ahaan, ATEX ee jawiga qarxa).
Rakibaadda iyo Dayactirka
Shuruudaha Rakibaadda
Saldhig heer sare ah oo leh meel bannaan oo ≥1m ah dhinacyada oo dhan si kulaylka loo kala diro.
Iska caabbinta dhulka ≤4Ω; naqshad ilaalin hillaac oo gooni ah.
Dayactirka Joogtada ah
Hubi heerka saliidda, midabka, iyo daadashada lixdii biloodba mar.
Tijaabi iska caabbinta dahaarka sannad kasta adoo isticmaalaya mitirka 2,500V.
Xal u helidda dhibaatooyinka
Kulayl xad dhaaf ah: Kormeer xirmidda hiitarka ama culaysyo aan caadi ahayn.
Falanqaynta Chromatography-ga Saliidda: Soo ogow calaamadaha hore ee dheecaanka gudaha ama burburka dahaarka.



Maxaad noo dooran lahayd
JIEZOU POWER, oo ah naqshadeeye xirfadle ah, soo saaraha iyo rakibaha xalka nidaamka korontada adduunka oo dhan, ayaa la aasaasay 1989, waxayna ku fadhidaa 200,000 mitir oo laba jibbaaran.
JIEZOU POWER, waxay inta badan maamushaa mashaariicda shabakadda korontada, 500KV EPC, warshadda korontada biyaha ee 230KV, saldhig koronto oo 115KV ah, iwm.
Warshadda JIEZOU POWER waxay soo saari kartaa nooca saliidda iyo nooca qalalan ee transformer-ka qaybinta, ugu badnaan 500KV 480MVA transformer, GIS, switchgear, substation, oo ku salaysan heerka ANSI/IEEE/DOE2016/CSA/IEC60076.
JIEZOU POWER waxay si isdaba joog ah u heshaa shahaadada ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Ilaa sanadka 2023, shirkadaha iyo warshadaha caalamiga ah waxaa lagu qaybiyaa Mareykanka, Kanada, Dubai, Dominican Republic, Filibiin, warshadaha iyo shirkadaha laanta Shiinaha waxay ku yaalliin magaalada BengBu, magaalada FengYang, magaalada HaiAn, magaalada TaiZhou, magaalada SuZhou, magaalada ShenYang, iyo magaalada FoShan.
Marka la eego mustaqbalka, aragtida JIEZOU POWER waa in la noqdo bixiyaha xalka nidaamka korontada ugu kalsoonida badan, la xalliyo caqabadaha maaraynta korontada ee ugu degdegga badan adduunka, la dedejiyo u gudubka meeraha ee tamarta la cusboonaysiin karo. Si qof walba u helo nolol kaarboon yar oo dhalaalaya. Si taas loo gaaro, waxaan sameyn doonnaa dadaallo badan.



Weydii Hadda!
Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.