+86 18068001229 01
Nidaamyada Shabaqyada Saddex-Waji ah ee Saliidda Waara
Astaamaha Muhiimka ah & Faa'iidooyinka
Qaboojiye hufan iyo waara
Iyada oo lagu dhex milmay saliid dahaadh tayo sare leh, qalabku wuxuu si wax ku ool ah u kala diraa kulaylka (qaboojinta ONAN/ONAF), isagoo ilaalinaya waxqabadka ugu wanaagsan xitaa marka culeysyo culus jiraan. Saliiddu waxay sidoo kale u shaqeysaa sidii dahaadhiye, iyadoo xoojinaysa badbaadada korantada iyo yareynta xirashada.
;Kalsooni Sare iyo Dayactir Yar
Dhisme adag oo leh dahaadh naxaas ah iyo nidaamyo dahaadh oo warqad-saliid ah oo horumarsan ayaa hubiya iska caabbinta cadaadiska kulaylka, qoyaanka, iyo wareegyada gaagaaban. Shuruudaha dayactirka ee ugu yar ayaa ka dhigaya mid ku habboon meelaha fog ama kuwa adag in la galo.
;Naqshad yar iyo mid casri ah
Waxaa laga heli karaa qiimeynta danabka laga bilaabo 11kV ilaa 33kV iyo awoodaha ilaa 5 MVA, oo leh qaab-dhismeed hal ama saddex-waji ah. Cabbirka is haysta wuxuu fududeeyaa rakibidda saldhigyada magaalooyinka, beeraha warshadaha, ama shabakadaha miyiga.
;La socodka Caqliga leh (Ikhtiyaar)
Dareemayaasha ku shaqeeya IoT (ikhtiyaar) waxay bixiyaan xog waqtiga-dhabta ah oo ku saabsan heerkulka saliidda, heerarka culayska, iyo ogaanshaha cilladaha, taasoo suurtogalinaysa dayactirka saadaalinta iyo yaraynta waqtiga shaqada.
;Deegaanka u fiican & kharash-ool ah
Hawlgalka buuqa yar (




Codsiyada
Shabakadaha Guryaha: Hoos u dhigista danabka dhexdhexaadka ah (11kV/33kV) ilaa 230/400V qoysaska.
;Warshadaha & Ganacsiga: Koronto deggan oo loogu talagalay warshadaha wax soo saarka, xarumaha xogta, iyo xarumaha wax iibsiga.
;Is-dhexgalka La Cusboonaysiin Karo: Ku xidhidda beeraha qorraxda/dabaysha shabakadaha danab-yar.
;Korontada Miyiga: Naqshad waara oo loogu talagalay deegaannada fog ama kuwa adag.
Tilmaamaha Farsamada
Kala duwanaanshaha danabka: 11kV ilaa 33kV (danab dhexdhexaad ah).
;Awoodda: 500 kVA ilaa 5,000 kVA.
;Soo noqnoqoshada: 50Hz/60Hz.
;Qaboojinta: ONAN (Saliid Hawada Dabiiciga ah ee Dabiiciga ah) ama ONAF (Saliid Hawada Dabiiciga ah ee lagu qasbay).
;Hufnaan: ≥98% marka uu buuxsamo (shahaadada IEC 61378).
Hubinta Tayada
Tijaabada adag waxay hubineysaa u hoggaansanaanta heerarka caalamiga ah:
Tijaabooyinka xoogga Dielectric si loo hubiyo hufnaanta dahaarka.
Cabbiraadaha lumista culayska iyo kor u kaca heerkulka.
Xaqiijinta u adkeysiga wareegga gaaban.
Shahaado ka haysta ISO 9001 (tayada), ISO 14001 (deegaan), iyo KEMA si loo helo badbaado iyo isku hallayn.
Maxaad Noo Dooranaysaa?
30+ Sano oo Khibrad ah: Naqshado la xaqiijiyay oo loogu talagalay xaaladaha cimilada iyo hawlgalka ee kala duwan.
;Shabakadda Taageerada Caalamiga ah: Kooxaha adeegga maxalliga ah iyo caawinta farsamada 24/7.
;Qiimaha Tartan: Xalalka la miisaami karo ee loogu talagalay baahiyaha miisaaniyadda iyo waxqabadka.
Xalalka Gaarka ah
Naqshado Gaar ah: Heerkulka aadka u daran, deegaannada daxalka leh, ama goobaha dhulgariirka.
;Casriyeynta Waxtarka Tamarta: Xirmooyinka Retrofit ee nidaamyada dhaxalka ah.



Faa'iidooyinka badeecada
1. Agabka Aasaasiga ah iyo Naqshadaynta Wareegga
Agabka Aasaasiga ah
Xudunta Amorphous Alloy:
Khasaaraha birta aadka u hooseeya (70-80% ka hooseeya birta silikoon ee dhaqameed), taasoo yaraynaysa qashinka tamarta iyo kharashyada hawlgalka.
Joogto sare iyo cidhiidhi birlabeed oo ku dhow eber ayaa yareeya buuqa iyo gariirka, taasoo ku habboon goobaha la deggan yahay iyo warshadaha.
Bir Silikoon ah oo Qabow-Duuban oo ku Salaysan Midhaha (CRGO):
Laydhka lagu jaro laysarka ama jaranjarada lagu dhejiyo ayaa yareeya khasaaraha hadda socda, isagoo gaaraya heer hufnaan ilaa 98.5%.
Jihaynta hadhuudhka ee la hagaajiyay waxay kor u qaadaysaa cufnaanta qulqulka magnetic-ka ee codsiyada danab sare leh (tusaale ahaan, 11kV–33kV).
Naqshadeynta Wareega
Dabayladaha Foil-ka oo leh Qaboojinta Socodka Saliidda:
Daloolada naxaasta ama aluminiumka ayaa yareeya qulqulka daadashada iyo xoogga wareegga gaaban. Wareegga saliidda ee dhex mara tuubooyinka wareegsan waxay xoojisaa kala-baxa kulaylka.
Lakabyada isku xiran ee gudbiyaha ayaa yareeya cadaadiska danabka isku leexashada waxayna hagaajiyaan adkeysiga wareegga gaaban.
Dabagalka Wire Litz ee Lakabaysan:
Fiilada Litz ee badan waxay yareysaa saameynta maqaarka iyo u dhawaanshaha, iyadoo yareyneysa iska caabbinta AC iyo khasaaraha xaaladaha soo noqnoqda sare.
Qaabeynta Aasaaska Saddex-Addimo ee Isku-dhafan:
Naqshadaynta isku-dhafan waxay dheellitirtaa qulqulka birlabta, iyadoo yareysa khasaaraha eber-taxane ah iyo hagaajinta isku-midnimada kulaylka.
2. Nidaamyada Daloolada
Dahaarka Isku-dhafka ah ee Warqadda Saliidda:
Warqad cellulose tayo sare leh oo lagu shubay saliid dahaadh leh (tusaale ahaan, saliidda macdanta naphthenic ama paraffinic) waxay bixisaa awood dielectric ah ilaa 300 kV BIL.
Waxay isku daraysaa xasilloonida kulaylka (waxay u adkaysataa heerkulka ilaa 140°C) iyo iska caabbinta dabka.
Dahaarka Resin-ka Epoxy (Nooca Qallalan ee Isku-dhafan):
Qayb ka mid ah resin epoxy ah oo u adkaysta dheecaanka si loogu daboolo gariiradda, kor u qaadida qoyaanka iyo iska caabbinta wasakhowga.
Dahaarka Nano-ga ee la xoojiyay:
Isku-darka epoxy-ga ee silica ku jira ayaa hagaajiya cimriga qayb ahaan ee sii daynta 30-50%, taasoo ku habboon deegaannada xeebaha ama warshadaha.
3. Maareynta Kulaylka
Qabowga Hawada-Saliida-Dabiiciga ah (ONAN):
Qaboojinta dadban iyada oo loo marayo hiitarka iyo qulqulka saliidda dabiiciga ah, oo ku habboon hawlgal joogto ah oo culeysyo la qiimeeyay leh.
Qaboojinta Hawada ee Qasabka ah (OFAF):
Marawaxadaha heerkulka la xakameeyo waxay xoojiyaan kala-baxa kulaylka, taasoo suurtogalinaysa awood xad-dhaaf ah oo 120% ah muddo gaaban.
Qaboojinta Bamka-Saliidda ee Ka Caawisa (OFWF):
Bamka wareegga saliidda iyo marawaxadaha hawada lagu qasbay waxay hagaajiyaan wareejinta kulaylka saldhigyada magaalooyinka ee cufnaanta sare leh.
La socodka Kulaylka Caqliga leh:
Dareemayaasha heerkulka ee ku jira iyo nidaamyada ku shaqeeya IoT waxay kiciyaan qaylo-dhaan, daadinta culayska, ama kicinta qaboojinta si looga hortago burburka dahaarka.
4. Naqshadeynta iyo Ilaalinta Dhismaha
Taangiga adag iyo Xerada
Taangiyada u adkaysta daxalka:
Qalabka birta ah ee galvanized-ka ah ama aluminiumka ee kulul ee lagu dahaadhay dahaarka polyurethane/budada waxay iska caabiyaan burburka UV, buufinta milixda, iyo soo-gaadhista kiimikada.
Xabadeynta Hermetic:
Taangiyada la alxamay ama la xidhxidhay oo leh gaaska EPDM waxay ka hortagaan daadashada saliidda iyo qoyaanka soo galaya, taasoo hubinaysa in hawlgalku aanu dayactir lahayn muddo tobanaan sano ah.
Daawaynta Ka-hortagga Daxalka:
Nidaamyada ilaalinta Kathodic iyo dahaarka u adkaysta daxalka waxay cimri dheereeyaan cimilada aashitada ama qoyan.
Astaamaha Badbaadada
Wallalka Gargaarka Cadaadiska:
Si toos ah u daadi gaasaska inta lagu jiro cilladaha gudaha (tusaale ahaan, wareegyada gaagaaban), taasoo ka hortagaysa dillaaca haanta.
Nidaamka Kaydinta Saliidda:
Taangiyada ilaalinta ama kuwa ilaaliya ee shaabadaysan waxay yareeyaan taabashada oksijiinta, taasoo yaraynaysa oksaydhka iyo sameynta dhoobada.
Ilaalinta Kororka:
Qalabka isku dhafan ee zinc oxide arresters (MOA) iyo surge capacitors-ka ayaa xakameynaya transients-ka uu hillaaca keeno.
5. Hawlaha Sare
Nidaamyada La Socodka Xaaladda (CMS):
Dareemayaashu waxay la socdaan heerkulka saliidda, falanqaynta gaaska milmay (DGA), heerarka culayska, iyo sii deynta qayb ahaan, taasoo suurtogalinaysa dayactirka saadaalinta iyada oo loo marayo SCADA.
Beddelayaasha Taabashooyinka Ku-meel-gaarka ah (OLTC):
Hagaajinta tuubada ee AI-ku-shaqeyso waxay wanaajisaa xakamaynta danabka marka la eego culayska shabaqyada isbeddelaya, taasoo yaraynaysa khasaaraha tamarta ilaa 5%.
Hal-abuurrada Deegaanka u Habboon:
Saliidaha dahaarka ku salaysan bayoolojiga (tusaale ahaan, dareerayaasha ester) oo leh bayoolaji sare iyo dab-shid hoose, oo la jaanqaadaya heerarka IEC 62721.
Codsiyada Muhiimka ah iyo Isbeddellada Mustaqbalka
Qaybinta Warshadaha iyo Magaalooyinka:
Warshad koronto oo awood sare leh (500kVA–5MVA), xarumo ganacsi, iyo magaalooyin caqli badan.
Is-dhexgalka Tamarta La Cusboonaysiin Karo:
Ku habboon saldhigyada beeraha dabaysha/qorraxda iyo shabakadaha yaryar, oo taageeraya socodka tamarta laba-geesoodka ah.
Horumarka Mustaqbalka:
Transformers-ka Xaaladda Adag (SSTs): Awood u yeelo beddelka DC-DC iyo dabacsanaanta shabakadda ee nidaamyada tamarta baahsan.
Dahaarka Is-bogsiinta: Alaabada Nanocomposite waxay si iskood ah u hagaajiyaan cilladaha yar yar ee dielectric.
Soo Koobid
Isbeddellada Qaybinta ee Saddex-Waji leh ee Saliidda ku dhex milmay ayaa ku fiican xudunta aan qaab-dhismeedka lahayn ee lumis yar, maaraynta kulaylka ee horumarsan, iyo nidaamyada badbaadada ee lakabka badan leh. Isku-darka hufnaantooda, ballaarintooda, iyo adkeysigooda ayaa ka dhigaya kuwo aan lagama maarmaan u ah shabakadaha korontada ee casriga ah, halka hal-abuurka sida saliidaha ku salaysan bayoolojiga iyo kuwa caqliga badan.



Weydii Hadda!
Wixii su'aalo ah ee ku saabsan alaabtayada ama qiimaha iibiyaha, fadlan noo dhaaf emaylkaaga, waanan kula soo xiriiri doonnaa 24 saacadood gudahood.